background image

User Manual

WISE-750

Intelligent Vibration Sensing 

Gateway

Содержание WISE-750

Страница 1: ...User Manual WISE 750 Intelligent Vibration Sensing Gateway...

Страница 2: ...ssumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our rep...

Страница 3: ...g information ready before calling Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete d...

Страница 4: ...WISE 750 User Manual iv...

Страница 5: ...ect to PCL M10 13 3 3 3 Isolated Digital Input 13 Figure 3 6 Isolated Digital Input Connection 13 3 3 4 Isolated Digital Output 14 Figure 3 7 Isolated Digital Output Connection 14 3 4 Hardware Install...

Страница 6: ...25 4 7 2 Feature Extraction Mode 26 4 7 3 Intelligent Mode 26 4 8 Device Communication 27 4 8 1 Modbus 27 4 9 Alarm Generation 27 4 10 System Requirements 27 Appendix A Specifications 29 A 1 Analog I...

Страница 7: ...Chapter 1 1 Introduction This chapter introduces WISE 750 and its typical applications Sections include Features Applications Installation Guide Software Overview Accessories...

Страница 8: ...us Analog Inputs 200kS s sampling rate Vibration sensor included Multiple selection of trigger type and sampling type LEDs for status indication 2 x Ethernet port for daisy chain Alarm generation thro...

Страница 9: ...low Chart 1 4 Accessories Advantech offers a complete set of accessory products to support the WISE 750 module These accessories include Sensor PCL M10 3E Industrial Accelerometer PSD A40W24 DIN Rail...

Страница 10: ...WISE 750 User Manual 4...

Страница 11: ...Chapter 2 2 Installation...

Страница 12: ...e following aspects to ensure proper installation Avoid physical contact with materials that could hold static electricity such as plastic vinyl and Styrofoam Whenever you handle the module grasp it o...

Страница 13: ...s act as trigger and digital outputs act as alarm The digital I O tests here are only to let you test the signal connection and make sure all the con nections work as expected For detailed signal conn...

Страница 14: ...WISE 750 User Manual 8...

Страница 15: ...ctions This chapter provides useful information about how to connect input and output signals to the WISE 750 Module via the I O con nector Sections include Overview IO Indicators and Pin Definition S...

Страница 16: ...l IO connectors and indicators Figure 3 1 Connector and Switch Locations Pin Assignment Connector Description Pin Description Pin Description CH0 Analog Input channel 0 CH1 Analog input channel 1 CH2...

Страница 17: ...is abnormal RUN Indicates if the program is running Channel Status Each of the analog input channel has a corresponded LED indicator The LED lights up when the channel alarm happens LED Status Off On...

Страница 18: ...ometers PCL M10 3E by default The sensor can be connected to the WISE 750 analog channel 0 3 directly How ever if you d like to connect your own sensor to the WISE 750 you should connect your sensor t...

Страница 19: ...put Each of the isolated digital input channels accepts bi directional 10 30 VDC voltage inputs This means that both positive and negative voltage can be applied to an iso lated input pin VIN Figure 2...

Страница 20: ...nd the WISE 750 module The signal cables must be kept away from strong electromagnetic sources such as power lines large electric motors circuit breakers or welding machines since they may cause stron...

Страница 21: ...on The WISE 750 has two LAN port with RJ45 connector To connected with WISE 750 you should use at least CAT 5e cable with RJ 45 connector to connect to the WISE 750 The WISE 750 supports daisy chain T...

Страница 22: ...WISE 750 User Manual 16...

Страница 23: ...Chapter 4 4 Device Configuration Sections include Software Interfaces IP Configuration Overview of WISE 750 Opera tion Data Acquisition Parameters Trigger Settings Operation Modes...

Страница 24: ...d to your computer when it starts 4 2 Software Interface There are two parts in WISE 750 utility One is the device tree view on the left hand side the other is specific settings The device will be lis...

Страница 25: ...rmed by WISE 750 itself Figure 4 2 Device Test Page Feature Extraction In this page the function of feature extraction can be set To activate this page the run mode should be set to Feature Extraction...

Страница 26: ...igure 4 4 Machine Learning Page Run All the results can be instantly viewed from this page Figure 4 5 Run Page Multiple Module Connection The software supports multiple connection in the system no mat...

Страница 27: ...etting 4 4 Overview of WISE 750 Operation The WISE 750 follows Figure 4 7 in its operation An iteration cycle includes data acquisition calculation and communication The data acquisition starts right...

Страница 28: ...mples to be retrieved in each iteration cycle Cycle Count Number of iteration cycles to be made in each trigger Figure 4 8 describes the reac tion when section count is set to a non zero value Figure...

Страница 29: ...Active High or LOW Active Low based on the settings On the other hand in the context of analog trigger the options would be changed to beyond or under trigger level In the meantime the filter can also...

Страница 30: ...effective when the process is already running See Figure 4 12 Figure 4 12 Analog Trigger and Cycle 4 6 3 Trigger Level This would only be available when using analog triggers This is the trigger volta...

Страница 31: ...hen understand the data features and will be able to set the criteria afterwards To use the datalogger switch the utility to Feature Extraction Page Options and Parameters Data Type Choose Feature Val...

Страница 32: ...ta set is saved to a file Each file contains data count of half of the section length For example if you set the file count to 100 and section length to 2048 there will be 100 files and each file cont...

Страница 33: ...g interface is in the Feature Extraction and ML Modeling page respectively The inspection result could either be retrieved from communication interfaces or corresponded digital output For example if W...

Страница 34: ...WISE 750 User Manual 28...

Страница 35: ...Appendix A A Specifications...

Страница 36: ...ture within 5 C of last auto calibration temperature 0 02 Over full operating temperature range 0 08 Offset error Operating temperature within 5 C of last auto calibration temperature 0 7 mV Over full...

Страница 37: ...us A 4 Isolated Digital Output Channels 4 Output Type sink NPN Sink Current 500 mA max channel Isolation Protection 2 500 VDC Opto Isolator Response 100 us A 5 General Power input 10 30VDC Power Cons...

Страница 38: ...WISE 750 User Manual 32...

Страница 39: ...Appendix B B Algorithms...

Страница 40: ...maximum of the absolute of the waveform Peak Max F n RMS The root mean square abbreviated RMS or rms is defined as the square root of the mean square the arithmetic mean of the squares of a set of nu...

Страница 41: ...Appendix C C I O Ranges...

Страница 42: ...3 30103 30203 30303 2 digit decimal MIN INT 30005 30105 30205 30305 2 digit decimal MEAN INT 30007 30107 30207 30307 2 digit decimal Peak INT 30009 30109 30209 30309 2 digit decimal Peak To Peak INT 3...

Страница 43: ...37 WISE 750 User Manual Appendix C I O Ranges...

Страница 44: ...e subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permiss...

Отзывы: