manualshive.com logo in svg
background image

 

 

 
 

IMPULSE

®

•Link 5 

Viewer and Professional 

User Manual 

 
 
 
 
 
 

 

 

 

 

 

 

                    

 
 
 
 

April 2020 

Part Number: 144-18171 R2 

                          © Copyright 2020 Magnetek 

Содержание IMPULSE Link 5

Страница 1: ...IMPULSE Link 5 Viewer and Professional User Manual April 2020 Part Number 144 18171 R2 Copyright 2020 Magnetek...

Страница 2: ...s DataLogger Tab 12 4 2 1 Parameter Tab 12 4 2 2 DataLogger Tab 13 4 3 Parameter File Display 14 4 3 1 Parameter Value Text Color 14 4 4 Workspace 14 4 4 1 DataLogger Parameter File Sets 14 4 4 2 Even...

Страница 3: ...Falls WI 53051 Telephone 800 288 8178 Website www magnetekmh com E mail field service magnetek com Fax Numbers Main 800 298 3503 Sales 262 783 3510 Service 262 783 3508 Magnetek Inc has additional sat...

Страница 4: ...ons in this manual do not take precedence over any of the following requirements relating to cranes hoists lifting devices or other equipment which use or include Magnetek products Instructions manual...

Страница 5: ...m signal checks while the electrical power is ON Improper programming of a drive with this software can lead to unexpected undesirable or unsafe operation or performance of the drive DISCLAIMERS No pa...

Страница 6: ...l version offers the above and much more Find drives over wireless industrial communications such as Ethernet and hardwired serial COM ports Read and write drive parameters Monitor real time Run statu...

Страница 7: ...ndows 10 operating system 32 bit or 64 bit Available USB port IMPULSE Link 5 Professional Kit IL5 PRO KIT Part Number IL5 Software Installer USB Flash Drive IL5 SOFTWARE USB Unikey USB Software Licens...

Страница 8: ...drive into a USB port on a PC and run ImpulseLink5_Install exe 2 When complete IMPULSE Link 5 will automatically launch 3 To enable IL5 Professional insert the Unikey dongle into a USB port on the PC...

Страница 9: ...rt Communication Profiles will be automatically created upon discovery NOTE The Find Drives scanner will continue to run for 15 minutes for Scan COM ports and Scan WDS or until a user clicks the Stop...

Страница 10: ...pports these Magnetek drives IMPULSE G VG Series 3 Series 4 IMPULSE G Mini IMPULSE D HHP OmniPulse DDC Series 1 OmniPulse DDC Series 2 includes built in Ethernet port OmniPulse DSD MagnePulse DMC Seri...

Страница 11: ...5 will default to the Parameters tab on startup if a DataLogger is not connected to the PC Once a DataLogger is connected it will automatically switch to the DataLogger tab and the Workspace will pop...

Страница 12: ...1 Parameter Tab Figure 4 The Parameter Tab New Create a Parameter file Open Open a Parameter DataLogger or Trend file Close Close an active Parameter DataLogger or Trend file Print Print the active vi...

Страница 13: ...rameter Drive Event or Trend file Close Closes an active Parameter Drive Events or Trend file Select New Trend Opens window to select a different Trend file Print Print the active data shown in the Vi...

Страница 14: ...eter set is lower than what is needed for that specific parameter i e changing the parameter from the drive keypad would not be allowed with the current access level Table 1 Parameter Value Text Color...

Страница 15: ...S4 will gather detailed information about the state of the drive The DataLogger Series 4 can log 5000 Run events 400 Alarm events 400 Fault events Approximately 300 hours of monitor data U01 01 U01 12...

Страница 16: ...d viewed in the Trends section of IMPULSE Link 5 This data can be used to analyze drive issues during operation such as motor overload Trend files are automatically generated on power up of the DLS4 a...

Страница 17: ...e trends for this date will be shown under Available Times on the right Click on the date time to highlight the trend to view and then choose Load Figure 11 Selecting the Desired Trend NOTE This may t...

Страница 18: ...of Runs recorded by the DLS4 Date Date the Run event ended Day Month Year Time Time the Run event ended Hour Minute Second Direction FWD or REV Duration sec Amount of time the Run command was active A...

Страница 19: ...collected Name Description Fault Number of the Fault stored in the DLS4 Date Date the Fault occurred Day Month Year Time Time the Fault occurred Hour Minute Second Assoc Run Associated Run number tha...

Страница 20: ...tal signals from the drive as well as signal names and ranges These signals can be selected in the Signal Selection pane Figure 12 Trend Navigation Overview 4 5 2 Trend File Information The Trend file...

Страница 21: ...2020 Page 21 of 47 4 5 3 Signal Name Select Analog and digital signals can be selected or deselected from the Signal Name Select pane The following shows the default selections when a trend is first v...

Страница 22: ...nal such as the monitor name or meaning terminal number and programmed parameter value Figure 15 Mouse Tooltip Examples 4 5 5 Signal Names Analog When an analog signal is selected the trend will popul...

Страница 23: ...d or off open The color of the name is the same as the color of the data graphed Figure 17 Digital Signal Names 4 5 7 Time Time is displayed on the bottom in HH MM SS using 24 hour format 4 5 8 Trackb...

Страница 24: ...rollbar to navigate through a Trend file The scrollbar is used to zoom in out or move from the beginning end of the Trend file 4 5 10 Sliding the Scrollbar Navigation from the beginning to the end of...

Страница 25: ...rag to expand or contract view Below is an example of zooming out The cursor turns into a double sided arrow Figure 20 Using the Scrollbar 2 Mouse wheel Position the mouse over the desired area on the...

Страница 26: ...Event information and Trending data 4 6 1 Parameter Data To print parameter data go to the Parameters tab and select the Parameter set from the Workspace Figure 21 Selecting the Parameter Set Click t...

Страница 27: ...printing Figure 23 Selecting a Specific Parameter Group To print select parameters shift click the desired block of rows to print or ctrl click to select non contiguous rows If a parameter was selecte...

Страница 28: ...6 2 Events In order to print Event data go to the DataLogger tab and select the Event set to be printed from the workspace Figure 25 Selecting an Event Click the Print icon which will bring up the IMP...

Страница 29: ...IMPULSE Link 5 Instruction Manual April 2020 Page 29 of 47 Users can use the scroll arrows in the Print preview to see Runs Alarms and or Faults Figure 27 Selecting Alarms...

Страница 30: ...Manual April 2020 Page 30 of 47 Figure 28 Selecting Specific Runs Alarms and or Faults Figure 29 Print Preview of Selected Data NOTE The selection options for the events under the DataLogger tab do n...

Страница 31: ...be printed from the workspace Figure 30 Selecting the Trend Click the Print icon which will bring up the IMPULSE Link 5 Print dialog Figure 31 Printing the Trend The printed data is based on the view...

Страница 32: ...3 About IMPULSE Link 5 User Manual Downloads the IMPULSE Link 5 User Manual from the internet provided the PC is connected Drive Manuals Opens Magnetek Material Handling s Product Manuals webpage http...

Страница 33: ...res and functions through single click buttons Clicking the Home button brings up the Welcome display too Figure 34 IMPULSE Link 5 Professional Start up screen with USB dongle inserted Users can autom...

Страница 34: ...3 Click the Start button to begin the scan WDS and COM port scan timeout is 15 minutes unless a user clicks the Stop button Ethernet scans finish more rapidly and automatically timeout within a few se...

Страница 35: ...e Find Drives feature Users may also create Communication Profiles manually 2 Check one or more of the boxes for the desired drive s to monitor 3 Click the Start button 4 If monitoring more than one d...

Страница 36: ...the Clear button to remove all Runs Alarms and Faults for this monitor 5 2 3 OmniPulse DDC Series 2 MagnePulse DMC Series 2 Flash Utility The OmniPulse DDC Series 2 DDC S2 and MagnePulse DMC Series 2...

Страница 37: ...eck for Updates button The newest version of the firmware may be manually downloaded from the Magnetek Material Handling website at http www magnetek com en Material 20Handling Downloads aspx Once the...

Страница 38: ...res and enhancements may be released without notice The software can be downloaded from the Magnetek Material Handling website at http www magnetek com en Material 20Handling Downloads aspx To check f...

Страница 39: ...IMPULSE Link 5 Instruction Manual April 2020 Page 39 of 47 If the user chooses to install the update immediately the Web Update Check Client will launch The installer may request a core prerequisite...

Страница 40: ...IMPULSE Link 5 Instruction Manual April 2020 Page 40 of 47 Once IMPULSE Link 5 is done installing the update it will automatically relaunch...

Страница 41: ...IMPULSE Link 5 Instruction Manual April 2020 Page 41 of 47 Appendices Appendix A Wiring for Wireless Diagnostic System Base Unit...

Страница 42: ...IMPULSE Link 5 Instruction Manual April 2020 Page 42 of 47 Appendix B Wiring for Wireless Diagnostic System Remote Unit IMPULSE G VG Series 4 G VG Series 3 and G Mini...

Страница 43: ...IMPULSE Link 5 Instruction Manual April 2020 Page 43 of 47 OmniPulse DDC Series 2 MagnePulse DMC Series 2...

Страница 44: ...IMPULSE Link 5 Instruction Manual April 2020 Page 44 of 47 OmniPulse DDC Series 1 MagnePulse DMC Series 1...

Страница 45: ...IMPULSE Link 5 Instruction Manual April 2020 Page 45 of 47 OmniPulse DSD...

Страница 46: ...ager and verify a Keyspan USB Serial Port appears after Step 2 NOTE If a Keyspan COM Port does not appear under Device Manager Ports try downloading the Keyspan USA 19HS Driver for Windows 7 8 and 10...

Страница 47: ...IMPULSE Link 5 Instruction Manual April 2020 Page 47 of 47 IL5 Professional kit contents 4 5...

Отзывы: