IMPULSE
®
•Link 5 Instruction Manual
April 2020
Page 19 of 47
4.4.5. Alarms
If an Alarm is detected during a Run, it will be logged under the Alarms tab. Each data point can be turned ON
or OFF for viewing purposes. For example, when
“Model” is deselected, it will not be displayed in the Events
shows the various data that is collected.
Name
Description
Alarm #
Alarm number in the DLS4.
Alarm
Name of the Alarm posted at the end of the Run event.
Date
Date the Alarm occurred [Day/Month/Year].
Time
Time the Alarm occurred [Hour:Minute:Second].
Assoc. Run #
Associated Run number that the Alarm occurred in.
Control
Control method of the drive.
Motion
Motion of the drive.
Table 3: Alarm Data
4.4.6. Faults
If a Fault is detected during a Run, it will be logged under the Faults tab. Each data point can be turned ON or
OFF for viewing purposes. For example, when
“Model” is deselected, it will not be displayed in the Events
window.
shows the various data that is collected.
Name
Description
Fault #
Number of the Fault stored in the DLS4.
Date
Date the Fault occurred [Day/Month/Year].
Time
Time the Fault occurred [Hour:Minute:Second].
Assoc. Run #
Associated Run number that the Fault occurred in.
Fault
Name of the Fault.
Fref [Hz]
Frequency reference at the time of the Fault.
Fout [Hz]
Output frequency at the time of the Fault.
Iout [A]
Output current at the time of the Fault.
Motor Speed [Hz]
Motor speed at the time of the Fault.
Vout [VAC]
Output voltage at the time of the Fault.
DC Bus [VDC]
Voltage on the DC Bus at the time of the Fault.
Power Out [HP]
1
Output power at the time of the Fault.
T-ref [%]
1
Torque reference at the time of the Fault.
Input Terminal Status
Status of the input terminals at the time of the Fault.
Output Terminal Status
Status of the output terminals at the time of the Fault.
Inverter Status
Status of the drive at the time of the Fault.
Elapsed Time [Hr]
Time since the last Fault was recorded.
Heatsink [°C]
Heatsink temperature at the time of the Fault.
Control
Control method of the drive.
Motion
Motion of the drive.
1
Only valid when the control method is Open Loop Vector or Flux Vector.
Table 4: Fault Data
– AC Drive
Содержание IMPULSE Link 5
Страница 43: ...IMPULSE Link 5 Instruction Manual April 2020 Page 43 of 47 OmniPulse DDC Series 2 MagnePulse DMC Series 2...
Страница 44: ...IMPULSE Link 5 Instruction Manual April 2020 Page 44 of 47 OmniPulse DDC Series 1 MagnePulse DMC Series 1...
Страница 45: ...IMPULSE Link 5 Instruction Manual April 2020 Page 45 of 47 OmniPulse DSD...
Страница 47: ...IMPULSE Link 5 Instruction Manual April 2020 Page 47 of 47 IL5 Professional kit contents 4 5...