background image

 

____________________________________________________________________________________________________ 

SKY-8101S Manual V04 20180321   

Copyright 2016 Advantech Co. Ltd. All rights reserved.     

Page 34

 

Air Filter 

Front replaceable 

System 
Management

 

Advantech BMC 

- Aspeed AST2500 BMC 
- Advanced Lights Out Management compliant to IPMI2.0 with 
security and availability enhancements 
- iKVM Support 
- Configurable shared or dedicated NIC support 

Physical

 

Dimension   
(W x D x H) 

438.00 x 506.20 x 44.20 mm (17.24" x 19.93" x 1.74") 

Weight (N.W) 

15kg 

Security 

Lockable front bezel and chassis intrusion sensor 

NOTE! 

1.

 

User can select to install two AC 700W PSU as SKY-8101S AC system, or to install two DC 
600W PSU as SKY-8101S DC system 

 

2.3.2 System Dimensions 

The system dimensions (in mm) are shown below: 

 

 

 

 

 

Figure 2-2: System Dimensions 

Содержание SKY-8101

Страница 1: ..._____________________________________________________________ SKY 8101 Manual V04 20180321 Copyright 2018 Advantech Co Ltd All rights reserved Page I SKY 8101 COMPACT 1U HIGH PERFORMANCE SERVER BASED ON INTEL XEON PROCESSOR SCALABLE FAMILY ...

Страница 2: ......

Страница 3: ... Advantech Co Ltd All rights reserved Page I Revision History Date mm dd yyyy Revision Modifications 09 05 2017 0 1 Initial version draft 11 16 2017 0 2 Add safety instructions 03 12 2018 0 3 Content update 03 21 2018 0 4 Update pictures 10 22 2018 0 5 Update Section 2 4 6 3 Validated Memory Modules Update Section 3 5 1 Air Filter Installation ...

Страница 4: ...ps you with the first steps with the SKY 8101S Section 2 Product Specification provides a detailed description of the SKY 8101S and its features Section 3 Configuration and Service describes how to change the SKY 8101S configuration or how to install and service replaceable items Section 4 Tips Tricks and Troubleshooting provides best practices and other information that may be helpful for operati...

Страница 5: ...ply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period...

Страница 6: ... eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Warnings Cautions and Notes Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are included to help you avoid damaging hardware or losing data Note Notes provide additional information We Appreciate Your Input Please let u...

Страница 7: ...k boot 25 1 3 6 4 Booting an OS via network boot 25 1 4 Getting Help Technical Support and Assistance 29 Chapter 2 Product Specification 30 2 1 Overview 31 2 2 Product Versions 32 2 3 Technical Specifications 33 2 3 1 SKY 8101S System Specification 33 2 3 2 System Dimensions 34 2 4 Detail Description 35 2 4 1 Front Elements 35 2 4 1 1 LEDs Details 35 2 4 1 2 Front Button Details 37 2 4 1 3 Fan Mod...

Страница 8: ... 2 1 Serial Console 64 3 2 2 2 USB Configuration 66 3 2 2 3 Trusted Computing if TPM1 2 present 67 3 2 2 4 Trusted Computing if TPM2 0 present 68 3 2 2 5 Virtualization 70 3 2 2 6 Platform Management 70 3 2 3 Hardware Setup 73 3 2 3 1 CPU Configuration 73 3 2 3 2 Northbridge 75 3 2 3 3 Southbridge 78 3 2 3 4 NVMe Configuration 83 3 2 3 5 Intel Virtual RAID on CPU 84 3 2 4 Server Management Setup 8...

Страница 9: ...ight 2016 Advantech Co Ltd All rights reserved Page 7 3 5 4 DIMMs 104 Chapter 4 Tips Tricks and Troubleshooting 106 Appendix A Connector Pinout and LED Information 108 Appendix B BIOS POST Code 116 Appendix C Power Supply Specification 124 Appendix D Declaration of Conformity 129 Appendix E Warranty and RMA 131 Appendix F Glossary 133 ...

Страница 10: ...re 2 6 Fan Module 38 Figure 2 7 Disk Bays 39 Figure 2 8 Disk Tray 40 Figure 2 9 System Rear View 41 Figure 2 10 PCIe Card Slot Details 42 Figure 2 11 System Top View Cover Removed 43 Figure 2 12 Block Diagram 44 Figure 2 13 DIMM and CPU Location 47 Figure 2 15 PCIe Cages Top View 49 Figure 2 18 Location of mSATA Sockets 51 Figure 2 20 System Airflow and Fans 54 Figure 2 21 AC PSU Details 55 Figure...

Страница 11: ...oot Menu 87 Figure 3 26 Post Boot Menu CSM16 Configuration 88 Figure 3 27 Post Boot Menu CSM Configuration 89 Figure 3 28 Save Exit Menu 90 Figure 3 13 Slide Top Cover Back 93 Figure 3 16 PCIe Card Cage Assembly 95 Figure 3 16 PCIe Card Cage Assembly 96 Figure 3 20 Unlocking the Disk Tray 97 Figure 3 21 Opening the Disk Tray 97 Figure 3 22 Removing the Disk Tray 97 Figure 3 23 Mounting the Drive i...

Страница 12: ...us Address List 47 Table 2 13 Validated DIMMs 47 Table 2 14 AC PSU Details 55 Table 2 15 DC PSU Details 56 Table 2 16 Accessories 58 Table 2 17 Spare Parts 59 Table 2 18 Related Products 59 Table 3 1 BIOS Setup Main Menu 63 Table 3 2 Serial Console Menu 65 Table 3 3 USB Configuration Menu 66 Table 3 4 Trusted Computing Menu TPM1 2 68 Table 3 5 Trusted Computing Menu TPM2 0 69 Table 3 6 Virtualizat...

Страница 13: ...09 Table A 2 USB 3 0 Type A Connector Pin Assignment or Pin Assignment 110 Table A 3 DisplayPort Connector Pin Assignment 111 Table A 4 SFP Connector Pin Assignment 113 Table A 5 SFP Connector LED Indication 114 Table A 6 RJ45 10 100 1000Base T Connector Pin Assignment 115 Table A 7 RJ45 Connector LED Indication 115 Table B 1 BOIS POST Codes 117 Table C 1 700W AC Power Supply Specification 125 Tab...

Страница 14: ..._____________________________________________________________________________________________ SKY 8101 Manual V04 20180321 Copyright 2018 Advantech Co Ltd All rights reserved Page 12 Chapter 1 Getting Started ...

Страница 15: ... various uses we do not guarantee that the given information is complete If you need additional information contact your Advantech representative The product has been designed to meet the standard industrial safety requirements It must not be used except in its specific area as specified in Section 2 3 Only personnel trained by Advantech or persons qualified in electronics or electrical engineerin...

Страница 16: ...fied in Technical Specifications This could damage the equipment The equipment should be in a controlled environment Caution Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer discard used batteries according to the manufacturer s instructions 16 The sound pressure level at the operator s position according to IEC 70...

Страница 17: ...ed to as the box in the remainder of this document When opening the box you will find the SKY 8101S embedded in protective foam and the accessory box embedded to the foam Remove the accessory box first and then pull out the unit including the protective foam using both hands Now remove the foam and the plastic sleeve on the unit After unpacking the unit please check for any visible damage of the u...

Страница 18: ...r need to install components in the SKY 8101S for any other reason please refer to Section 3 3 1 3 1 Rack Mounting The SKY 8101S server is designed to be as a rack server Please follow the basic guidelines below for rack mounting Mount the mounting ears on the each side of the unit using the screws included Note You need A PH2 screw driver 1 Locate the threaded mount holes on the chassis on the si...

Страница 19: ... line up with those of the mounting bars of the 19 inch cabinet Choose a mounting location that does not block any air inlet and air outlet areas of the unit it is also recommended to factor in heat generated by adjacent equipment and to avoid exposure to direct sunlight when mounting the unit If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack enviro...

Страница 20: ..._________________________________ SKY 8200 Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 18 Step 2 Mount the chassis inner member to the chassis Step 3 Attach the cabinet outer member to the rail Step 4 Mount the chassis into the cabinet ...

Страница 21: ...t the power rating of the outlet and the SKY 8101S PSU match Please also make sure that the primary circuit and all power distribution in not overloaded Inrush current and steady state power specifications for the SKY 8101S can be found at the type label on the bottom of the unit Connect the power cords to the PSU modules first and then to the power outlets The unit will automatically power on aft...

Страница 22: ... a UART interface with transmit receive buffers and modem handshake signals For a terminal PC to connect to the console function on the SKY 8101S with a micro USB to USB cable the CP2102 driver is available for download from Silicon Labs website hyperlink below and must be installed on the terminal PC The PC can for example run a Linux 2 4 or 2 6 kernel or Windows XP The micro USB port is bus powe...

Страница 23: ...n as shown below Please use the actual COM port s number on the client machine instead of COM1 1 Specify COM1 under serial line and 115200 for speed no parity no flow control 2 Check Serial for connection type 3 Check VT100 for keypad in the keyboard submenu 4 Check Colour or Both for Indicate bolded text in the colours submenu 5 Click the Open button and a PuTTY terminal screen will appear Figure...

Страница 24: ...______________________________________________________________________ SKY 8200 Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 22 Figure 1 4 PuTTY Serial Configuration Figure 1 5 PuTTY Keyboard Settings ...

Страница 25: ...1 6 PuTTY Colour Settings If the connection is successful you should be able to see the BIOS Power On POST screen after powering the unit Figure 1 7 BIOS POST Screen Note Please note that the BIOS is doing some initial start up work while the console is still not active It may take a while until the BIOS POST screen appears On the other hand the BIOS has been optimized for minimum boot time The ...

Страница 26: ...reate a Live USB stick using LiLi available via http www linuxliveusb com or a similar tool If you want to use a serial console please make sure to configure the Linux properly 115200bd 8N1 no handshake Enabling serial support in the Linux bootloader grub or similar as well as kernel debug messages via serial console may be valuable for potential troubleshooting 2 Install the USB stick in one of t...

Страница 27: ...S options In the Advanced Network Stack Configuration Menu is configured properly Table 1 2 PXE BIOS Options Network Stack Enabled Enables the UEFI Network Stack PXE boot usually does not allow for OS installation over network as the PXE client will only load a single file from the boot server Similarly booting Linux over network is usually a two stage process In the first step a boot loader such ...

Страница 28: ... separate network subnet for network booting as the DHCP required for PXE booting may conflict with existing DHCP servers in your network The PXE client in the SKY 8101S sends the system s GUID as part of the DHCP Request Some boot servers have mechanisms to automatically configure the target OS image based on the client system s GUID Using this mechanism allows to use the same boot server for net...

Страница 29: ...he client with Legacy option Power up the client system and go to the BIOS by hitting the DEL key Once you are in the bios track to the POST BOOT tab then inside the CSM Parameters there select the Network option to Legacy After doing this do not for get to change the boot sequence Figure 1 12 Booting the Client with Legacy Option Screen_1 Figure 1 13 Booting the Client with Legacy Option Screen_2...

Страница 30: ...t system and go to the BIOS by hitting the DEL key Once you are in the bios track to the POST BOOT tab then inside the CSM Parameters there select the Network option to UEFI Figure 1 14 Booting the Client with UEFI Option Screen_1 After doing this do not for get to change the boot sequence Reboot the client system and to get the installation menu And hit enter to begin the installation Figure 1 15...

Страница 31: ...rmation about the SKY 8101S and related products 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Worldwide contact information can be found on http www advantech com 3 Please have the following information ready before you call be sure to include this information in your email Product name and serial num...

Страница 32: ...__________________________________________________________________________________________ SKY 8200 Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 30 Chapter 2 Product Specification ...

Страница 33: ...ration technologies such as GPU DSP and FPGA cards Architected around the new Intel Xeon Processor Scalable Family the single socket SKY 8101S combines cutting edge performance with the ruggedness reliability and long system lifecycles required by the industry With integrated security and compression offload based on Intel QuickAssist technology and two onboard 10GbE ports with SR IOV and RDMA sup...

Страница 34: ...redundant AC 700W PSU 4x bay 4x SAS SATA 4 bay 2 5 4x SATA HDD SSD Compuware AC 700W SKY 8101SAS 0001E 20 1U server w GSMB 8101 single Skylake SP socket redundant DC 600W PSU 4x bay 4x SAS SATA 4 bay 2 5 4x SATA HDD SSD Compuware DC 600W SKY 8101LAS 0010E 27 5 1U server w GSMB 8101 single Skylake SP socket redundant AC 850W PSU 10x bay 8x SAS SATA 2x NVMe 10 bay 2 5 8x SATA HDD SSD 2x NVMe SSD FSP...

Страница 35: ...x USB3 0 2 0 1x microUSB console 5x LEDs Power ID 3x SW definable Rear IO 2x GbE LAN RJ45 1x Display port 2x USB3 0 2 0 2x 10GE SFP 2x hole ground lug Ethernet Gigabit Ethernet Interface 10 100 1000 Mbps 10 Gigabit Ethernet Interface 1Gbps 10Gbps Controller GbE LAN1 Intel i210 AT GbE LAN2 Intel i210 AT 10GbE SFP LAN1 2 Integrated into PCH with SR IOV and RDMA support Connector RJ 45 x 4 SFP x 2 St...

Страница 36: ...nt compliant to IPMI2 0 with security and availability enhancements iKVM Support Configurable shared or dedicated NIC support Physical Dimension W x D x H 438 00 x 506 20 x 44 20 mm 17 24 x 19 93 x 1 74 Weight N W 15kg Security Lockable front bezel and chassis intrusion sensor NOTE 1 User can select to install two AC 700W PSU as SKY 8101S AC system or to install two DC 600W PSU as SKY 8101S DC sys...

Страница 37: ...ont I O Front I O board with 1x micro USB console connector and 1x USB 3 0 port C Front cover Front bezel with replaceable air filter D Key lock Key lock E Fan Modules Five swappable fan modules allow service without opening top cover removing unit from rack F Fan Status LED Fan status LED indicating power normal operation and failure status G 2 5 Drive Bays Four 2 5 SAS SATA HDD SSD bays 2 4 1 1 ...

Страница 38: ... event A critical system failure has a significant impact to the system it means that the system can either not continue to operate or it is operating under a non redundant power or cooling condition resulting in increased risk for system failure The fault condition is defined following If any BMC sensor does pass a critical threshold Or a critical discrete sensors is asserted e g processor therma...

Страница 39: ...C sensor event such as SEL_FULL being asserted or Case_Intrusion sensor having triggered The MNR LED can be changed to overwrite mode and turned on or off by the PICMG Set FRU LED State command In this mode BMC does not change the LED in any condition A5 Green Power State LED This LED indicates that the unit is powered on The Payload power is on 2 4 1 2 Front Button Details The SKY 8101S supports ...

Страница 40: ...carries high performance fans for optimized air flow and has an integrated fan status LED to simplify identifying a faulty module during service operation To extract or install the fan module please press the latch handle following the arrow indicator Figure 2 6 Fan Module Table 2 5 Fan Module Item Element Description FM2 Fan LED Status LED green When lit indicates normal operation of the fan modu...

Страница 41: ...served Page 39 2 4 1 4 Disk Bay Details The SKY 8101S supports four hot swappable 2 5 HDDs SSDs at the front Figure 2 7 Disk Bays Table 2 6 Disk Bay Item Element Description F8 2 5 Disk Tray Disk 1 F9 2 5 Disk Tray Disk 2 F10 2 5 Disk Tray Disk 3 F11 2 5 Disk Tray Disk 4 Each Disk Bay has an integrated disk tray that includes a handle locking mechanism as well as drive LEDs ...

Страница 42: ...Copyright 2016 Advantech Co Ltd All rights reserved Page 40 Figure 2 8 Disk Tray Table 2 7 Disk Tray Item Element Description DT1 LOCK Locks the tray in the bay when in the left position DT2 LED Activity LED amber DT3 LED Status LED DT4 Button Pushing the button will allow the tray handle to open if unlocked DT5 Handle Tray handle ...

Страница 43: ...A PSU Module Hot swappable redundant 700W AC or 600W DC PSU B Advantech NIC Card Slot Dedicated Slot for Advantech Personalization card PCIe gen 3 x4 C PCIe Extension Slots One low profile extension slot PCIe gen 3 x8 D Display Port Display Port E SFP port Two 10GbE SFP ports F Copper port Two copper GbE management ports G USB port Two USB 3 0 Type A ports H Ground Lug Two hole ground lug for equi...

Страница 44: ...ails Table 2 9 PCIe Card Slot Details Item Element Description Power per PCIe slot R9 PCIe Slot Right Side 1 Full height full length card slot at top right Maximum 100W for total two slots default Maximum 300W for total two slots with additional customized power cables R10 PCIe Slot Right Side 2 Full height full length card slot at bottom right R11 PCIe Slot Left Side 1 Half height Low Profile car...

Страница 45: ...ystem Figure 2 11 System Top View Cover Removed Table 2 10 Rear Panel List Item Element Description IS1 Intrusion Switch Switch for chassis intrusion detection CG1 PCIe Card Cage Cage for right cards 1 2 R9 R10 CG2 PCIe Card Cage Cage for left cards 1 2 R11 R12 CG8 Drive Tray Assembly 2 5 drive tray assembly including SAS backplane CG9 Fan Cages Cages hosting fan modules FB1 Fan Middle Board Fan m...

Страница 46: ...21 Copyright 2016 Advantech Co Ltd All rights reserved Page 44 2 4 4 System Block Diagram Figure 2 12 Block Diagram 2 4 5 Processor s The SKY 8101S supports single Intel Xeon Processor Scalable Family The table below gives an overview of the processor SKUs for communication infrastructure which can be supported on the SKY 8101S ...

Страница 47: ...ns may apply If you re interested in the support of other CPU SKUs please contact your Advantech representative For details on the features of the Intel Xeon Processor Scalable Family please refer to documentation available from Intel 2 4 5 1 Processor Feature Details Supports a 1 0 MB Mid Level Cache MLC per core non inclusive with the LLC Supports Intel Hyper Threading Technology Intel HT Techno...

Страница 48: ...2016 Advantech Co Ltd All rights reserved Page 46 Support DDR4 Memory Speeds 2666 2400 2133 1866 MT s 64 bit wide Channels plus 8 bits of ECC Support for Each Channel DRAM Density 4Gb 8Gb DRAM Ranks RDIMM Single Rank Dual Rank LRDIMM Single Rank Dual Rank Quad Rank Octa Rank Integrated Dual SMBus Master Controllers Support Apache Pass DIMMs ...

Страница 49: ...on CPU Channel H W Address Device Address D1 CPU1 F SA 2 0 100 1010 101x A8 D2 CPU1 E SA 2 0 010 1010 100x A4 D3 CPU1 D SA 2 0 000 1010 001x A0 D4 CPU1 A SA 2 0 000 1010 000x A0 D5 CPU1 B SA 2 0 010 1010 100x A4 D6 CPU1 C SA 2 0 100 1010 000x A8 D1 D2 D3 D4 D5 D6 Figure 2 13 DIMM and CPU Location 2 4 6 3 Validated Memory Modules The following list summarizes the modules validated on the SKY 8101S ...

Страница 50: ...st of validated peripherals or if you would like to use modules not listed Other configurations are available on request 2 4 7 QuickAssist Accelerator QuickAssist is used by applications running on the IA cores to accelerate and offload processing The integrated QuickAssist accelerator of the PCH appears to software as a PCIe endpoint and is used as a look aside coprocessor It supports the feature...

Страница 51: ...Connectors are located at F and labeled 1 and 2 The two management ports are implemented using Intel i210 Ethernet Controllers with PCIex1 connectivity to the PCH and also provide access to the BMC over LAN via NC SI interfaces 2 4 9 PCIe Expansion The SKY 8101S supports a total of four PCIe extension slots for 2 full height full length one half height low profile PCIe card and one half height Adv...

Страница 52: ...reserved Page 50 The PCI Express port s are fully compliant to the PCI Express Base Specification Revision 3 0 PCIe 3 0 Support for PCI Express Gen 3 8 0 GT s Gen 2 5 0 GT s and Gen 1 2 5 GT s Up to 48 PCIe lanes and group as three x16 Port1 Port2 and Port3 CPU x16 port may negotiate down to x8 x4 CPU x8 port may negotiate down to x4 PCH x4 port may negotiate down to x2 x1 ...

Страница 53: ...ions The BIOS performs probing initialization and configuration of the SKY 8101S and initializes the OS boot process at the end of POST Power On Self Test Regular BIOS output as well as the setup menu are displayed via Display Port or serial console Please refer to Section 3 2 the console connection process The BIOS Setup Menu is described in detail in Section 3 2 BIOS Error Codes used during POST...

Страница 54: ...ed Platform Management Advanced Platform Management is supported via an integrated BMC running IPMI2 0 compliant system management firmware Several enhancements have been made to standard white box server management code to enhance reliability and serviceability of the system including but not limited to Improved thermal management to cover special scenarios as well as fan degradation failure Chas...

Страница 55: ...d All rights reserved Page 53 Main system voltages 12V 5V 3 3V Standby voltages 5V_SB 3 3V_SB RTC battery CPU core and IO voltages DRAM voltages PCH voltages Moreover the following temperatures are supervised Air inlet and outlet temperatures CPU temperatures DIMM temperatures if DIMMs used support a temperature sensor PCH temperature PSU temperature via PMBus ...

Страница 56: ...platform management introduces a special safe guard mechanism to assure normal operation under special conditions Should any other thermal sensor than the CPUs cross an upper threshold the BMC will override the Smart Fan control and turn all fans to full on as long as such special condition applies Advanced Platform Management takes similar actions when it detects a fan failure or severe degradati...

Страница 57: ...U Details Item Element Description PS1 Fan PSU fan and air outlet area PS2 Handle Handle for extraction insertion PS3 Power Connector IEC 320 C 14 power connector PS4 Lock Lock for locking unlocking the module Pull left to unlock PS5 Status LED Green LED indicating normal operation when lit Amber LED indicating abnormal operation when lit Caution 1 DO NOT remove the PSU before unplugging the power...

Страница 58: ...S3 Power Connector DC power connector PS4 Lock Lock for locking unlocking the module Pull left to unlock PS5 Alarm LED Red LED indicating a failure or degradation when lit PS6 Status LED Green LED indicating normal operation when lit Amber LED indicating abnormal operation when lit Caution 1 DO NOT remove the PSU before unplugging the power cable power cord 2 For 1 1 redundant system power only ON...

Страница 59: ... 18 green and yellow wire of earth of building to the protective earthed terminal of the equipment 4 Connect signal cables to the product 5 Connect power cord to the product 6 Ensure correct polarity of 44 65 V dc connections 6 1 44V 65VDC is and RTN is if DC power source outputs positive voltage 6 2 44V 65VDC is and RTN is if DC power source outputs negative voltage 7 Turn ON the power source Cau...

Страница 60: ...r iTCO_wdt ko Please refer to Linux as well as PCH documentation should you need more details The 2nd watchdog is implemented as an IPMI compliant watchdog timer in the BMC and supports more sophisticated operation modes such as pre timeout interrupts Standard utilities such as ipmitool can be used for configuring and strobing this watchdog Please refer to the IPMI specification for a detailed des...

Страница 61: ...d products are available for ordering Table 2 18 Related Products Order Number Description SKY 8101SAS 0000E 20 1U server w GSMB 8101 single Skylake SP socket redundant AC 700W PSU 4x bay 4x SAS SATA SKY 8101SAS 0001E 20 1U server w GSMB 8101 single Skylake SP socket redundant DC 600W PSU 4x bay 4x SAS SATA SKY 8101LAS 0010E 27 5 1U server w GSMB 8101 single Skylake SP socket redundant AC 850W PSU...

Страница 62: ...________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 60 Chapter 3 Configuration and Service ...

Страница 63: ...TIO BIOS Users can modify BIOS settings and control the special features of the SKY 8101S using the BIOS setup menu Note Please note that Advantech supports shipping the SKY 8101S with custom BIOS defaults to simplify the deployment and integration for our customers Please contact your Advantech representative if you want to receive more information regarding this service The BIOS Setup Menu can b...

Страница 64: ...vailable in a given menu page or a submenu thereof Auxiliary text providing information about the selected setup item is displayed in the top right corner Figure 3 2 BIOS Setup Screen Organization 3 2 1 Main Setup Menu If security protection has been enabled previously see Section 3 2 5 you will be prompted for the BIOS password upon entering the BIOS Setup After a successful check or if password ...

Страница 65: ...System Language Display only Selects the Setup Menu Language Only English is supported on the SKY 8101S System Date MM DD YY Displays and sets the system date as used by the BIOS System Time HH MM SS Displays and sets the system time as used by the BIOS Access Level Display Only Shows the user privilege level according to the security settings If password protection has not been enabled this will ...

Страница 66: ...uration to go to the sub menu for that item Users can display an Advanced BIOS Setup option by highlighting it using the Arrow keys The Advanced BIOS Setup screen is shown below The sub menus are described on the following pages Figure 3 4 Platform Setup Main Screen 3 2 2 1 Serial Console The settings for console can be accessed in this menu This sub menu allows you to change the settings used for...

Страница 67: ...eived serial character for both serial ports Stop Bits 1 2 Configure the number of stop bits transmitted and received in each serial character for both serial ports Parity None Even Odd Mark Space Configure if parity bit is generated transmit data or checked receive data between the last data word bit and stop bit of the serial data for both serial ports Flow Control None Hardware RTS CTS Configur...

Страница 68: ...S Default value is always Enabled which means Legacy Console Redirection is enabled for Legacy OS 3 2 2 2 USB Configuration This sub menu allows you to change the settings used for USB and to get an overview of the USB devices detected by the BIOS 4 Figure 3 6 Platform Setup USB Configuration Menu Table 3 3 USB Configuration Menu Group Setup Item Access Options Description None USB Support Disable...

Страница 69: ... sec 5 sec 10 sec 20 sec Set the time out value for USB transfers Device reset time out 10 sec 20 sec 30 sec 40 sec Set the time out value for USB mass storage device Start Unit command Device power up delay Auto Manual Select device power up delay control way Device power up delay in seconds 5 Set device power up delay when Device power up delay choose Manual 3 2 2 3 Trusted Computing if TPM1 2 p...

Страница 70: ...Operation None TPM Clear Choose TPM operation for next boot Device Select TPM1 2 TPM2 0 Auto TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support to TPM 2 0 devices Auto will support both with the default set to TPM 2 0 devices if not found TPM 1 2 devices will be enumerated Current Status Information TPM Status Display Only Shows TPM Enablement Status TPM Active Status D...

Страница 71: ...CR Bank Disabled Enabled Enable SHA256 PCR Bank Pending operation None TPM Clear Choose TPM operation for next boot Platform Hierarchy Disabled Enabled Enable or Disable Platform Hierarchy Storage Hierarchy Disabled Enabled Enable or Disable Storage Hierarchy Endorsement Hierarchy Disabled Enabled Enable or Disable Endorsement Hierarchy TPM2 0 UEFI Spec Version TCG_1_2 TCG_2 Select the TCG2 Spec V...

Страница 72: ...latform Setup Virtualization Table 3 6 Virtualization Group Setup Item Access Options Description None Intel Virtualization Technology Enabled Disabled Enable or disable BIOS support for the Vanderpool Technology Intel R VT d Enabled Disabled Enable or disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR ACPI Tables SR IOV Support...

Страница 73: ...ntel SpeedStep Technology When enabled OS sets CPU frequency according load When disabled CPU frequency is set at max non turbo P state coordination HW_ALL HW_ALL hardware coordination is recommended over SW_ALL and SW_ANY software coordination CPU C6 report Enable Disable Enable Disable CPU C6 ACPI C2 report to OS Recommended to be enabled Package C State limit C0 C1 state C2 state C6 non Retenti...

Страница 74: ... Yes On every reset Erase Log Options When log is full Clear Log Do not log any more Select the action to be taken when log is full System event log SEL Components Enable Disable Change this to enable or disable all features of System Event Logging during boot Erase SEL No Yes On next reset Yes ON every reset Choose options for erasing SEL When SEL is Full Do Nothing Erase Immediately Choose optio...

Страница 75: ...egacy term and the related functionality is split over the CPU and PCH portions of the SoC Similarly the terms South Bridge and North Bridge are legacy terms and do not represent the silicon implementation any more However those terms are kept consistent with previous products to allow users to navigate more easily The sub menus are described on the following pages Figure 3 11 Hardware Setup 3 2 3...

Страница 76: ...e logical processor threads Execute Disable Bit Enable Disable Execute Disable Bit allows the processor to classify areas in memory where application code can be executed and cannot preventing certain classes of malicious buffer overflow attacks when combined with a supporting operating system Intel TXT Support Enable Disable Enable Disable Intel TXT Hardware Prefetcher Enable Disable Enable or di...

Страница 77: ...roller and related features of the SoC Figure 3 13 Hardware Setup Northbridge Table 3 9 Northbridge Group Setup Item Access Options Description None DIMM Information N A Select sub menu Static Virtual Lockstep Mode Enable Disable Static Virtual Lockstep Mode enable disable Mirror mode Disable Mirror Mode 1LM Mirror mode will set entire 1LM memory in system to be mirrored Memory Rank Sparing Enable...

Страница 78: ...lect Rank Interleaving setting Patrol Scrub Enable Disable Select to enable disable Patrol Scrub Support Data Scrambling Auto Enable Disable Select to auto to enable the Scrambler PCI Express Ports Configuration N A Select sub menu 3 2 3 2 1 DIMM Information Figure 3 14 Hardware Setup DIMM Information 3 2 3 2 2 PCI Express Ports Configuration This sub menu contains settings for the PCIe subsystem ...

Страница 79: ...Enable PCIe hot plug Socket 0 PCIe port control DCA Support Enabled Disable Enables Direct Cache Access IOU0 PCIe Port x8x8 x16 Auto Select PCIe port bifurcation PORT 1A Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings PORT 1C Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings IOU1 PCIe Port x8x4x4 x8x8 Auto Sele...

Страница 80: ...e Disable Intel Volume Management Device Technology on specific root port PORT 2B Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings PORT 2B VMD Enabled Disable Enable Disable Intel Volume Management Device Technology on specific root port PORT 2C Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Change PCI Express Devices Settings 3 2 3 3 Southbrid...

Страница 81: ...ngs N A Select sub menu Runtime Error Logging N A Select sub menu PCH Compatibility RID Enable Disable Enable or Disable PCH s CCRID SMBus Controller Enable Disable Enable or Disable SMBus CDevice PCH state after G3 Power on Select S0 S5 for ACPI state after a G3 3 2 3 3 1 SATA Configuration Figure 3 17 Hardware Setup SATA Configuration Table 3 12 SATA Configuration Group Setup Item Access Options...

Страница 82: ... RAID 1 AHCI Mode 2 RAID Mode SATA Controller Enabled Disabled To enable the SATA controller sSATA Mode AHCI Only AHCI Mode support sSATA Controller Enabled Disabled To enable the sSATA controller SATA Hot Plug Port 0 Enable Disable Designates this port as Hot Pluggable SATA Hot Plug Port 1 SATA Hot Plug Port 2 SATA Hot Plug Port 3 SATA Hot Plug Port 4 SATA Hot Plug Port 5 SATA Hot Plug Port 6 SAT...

Страница 83: ...USB Configuration Group Setup Item Access Options Description None USB Port 0 Disable Enabled Disabled Enable Disable this USB Physical Connector physical port USB Port 1 Disable USB Port 2 Disable USB Port 3 Disable USB Port 4 Disable USB 3 0 Port 0 Disable Enabled Disabled Enable Disable this USB Physical Connector physical port USB 3 0 Port 1 Disable USB 3 0 Port 2 Disable USB 3 0 Port 3 Disabl...

Страница 84: ...I Settings Table 3 14 ACPI Settings Group Setup Item Access Options Description None Enable ACPI Auto Configuration Enabled Disabled Enable or disable BIOS ACPI auto configuration Enable Hibernation Enabled Disabled Enable the system ability to hibernate OS S4 sleep state this option may be not effective with some O S Lock Legacy Resources Enabled Disabled Enable lock of legacy resources 3 2 3 3 4...

Страница 85: ... reserved Page 83 Figure 3 20 Hardware Setup Runtime Error Logging Table 3 15 Runtime Error Logging Group Setup Item Access Options Description None System Errors Enabled Disabled Auto System error enabling and logging setup option 3 2 3 4 NVMe Configuration This menu contains settings for NVMe controller and Drive information Figure 3 21 Hardware Setup NVMe Configuration ...

Страница 86: ...___________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 84 3 2 3 5 Intel Virtual RAID on CPU This menu contains settings for Intel VMD for Volume Management Device Configuration Figure 3 22 Hardware Setup Intel VROC ...

Страница 87: ... Status Display only Passed BMC self test status indication during power on process OS Watchdog Timer Enable Disable If enabled starts a BIOS timer which can only be shut off by Management Software after the OS loads Helps determine that the OS successfully loaded or follows the OS Boot Watchdog Timer OS Wtd Timer Timeout 5 minutes 10 minutes 15 minutes 20 minutes Configure the length of the OS Bo...

Страница 88: ...g installed is required each time the system boots and or an attempt is made to enter the Setup program Figure 3 24 Security Menu Note 1 If set the Password Check is Setup then this only limits access to Setup and is only asked for when entering Setup 2 If set the Password Check is Always then this is a power on password and must be entered to boot or enter Setup In Setup the User will have Admini...

Страница 89: ...fine the boot priorities based on the application Figure 3 25 Post Boot Menu Table 3 17 Post Boot Menu Group Setup Item Access Options Description None Setup Prompt Timeout 1 Number of seconds to wait for setup activation key Bootup NumLock State On Select the keyboard NumLock state Quiet Boot Disabled Enables or disables Quiet Boot option Network Stack Disabled Enables or disables boot via Networ...

Страница 90: ...users to configure the support for legacy BIOS CSM16 Figure 3 26 Post Boot Menu CSM16 Configuration Table 3 18 CSM16 Configuration Group Setup Item Access Options Description None GateA20 Active Upon Request Always UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Force BIOS Keep...

Страница 91: ...ption ROMs Figure 3 27 Post Boot Menu CSM Configuration Table 3 19 CSM Configuration Group Setup Item Access Options Description None CSM Support Enabled Disabled Enables or disables the Compatibility Support Module Boot option filter UEFI and Legacy Legacy Only UEFI Only This item allows to control the execution of legacy and UEFI compliant Option ROMs Network Do not launch UEFI Legacy This item ...

Страница 92: ...3 20 Save Exit Menu Options Group Setup Item Description None Save Changes and Exit Exit setup after saving the changes Does not update User defaults Discard Changes and Exit Exit setup without saving any changes Save Changes and Reset Reset system after saving the changes Does not update User Defaults Discard Changes and Reset Reset system without saving the changes Save Options Save Changes Save...

Страница 93: ...0180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 91 Group Setup Item Description Save Options Restore User Defaults Restores the User defaults to all the setup options Boot Override UEFI boot device This option allows you to override the specified boot order and use a different boot device for the next boot ...

Страница 94: ...____________________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 92 ...

Страница 95: ... cover is secured by 2 thumb screws at rear and 1 M3 screw at side To remove the top cover loosen the thumb screws and M3 screw When unlocked a spring inside the thumb screw will notably push the screw head towards you After that slide the top cover backwards until the front flange of the top cover disengages with the unit s face plate and then lift off and remove the top cover M3 screw Thumb scre...

Страница 96: ...card cage CG1 b Two rear thumb screws for the Low profile card cage CG2 3 Grab the card cage and pull the card cage evenly and straight to the top The pull push direction must be with an angle of 90 from the PCIe connector see below figure You should feel a small bump when the riser card disengages with the motherboard Keep pulling the card cage to the top until it is fully removed from the chassi...

Страница 97: ...tech Co Ltd All rights reserved Page 95 11 Install the top cover 12 Reconnect primary power and power on the unit 13 Enter the BIOS setup menu launch the EFI shell and use the PCIe device display command to validate that the newly installed board s has have been properly recognized 14 Leave the BIOS and boot the OS Figure 3 16 PCIe Card Cage Assembly ...

Страница 98: ...________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 96 Figure 3 16 PCIe Card Cage Assembly ...

Страница 99: ...5 HDD SSD Drives Note You need A PH2 screw driver A standard 2 5 HDD SSD 1 Open the front cover C 2 Locate the disk tray you want to install the disk in F8 to F11 3 Unlock the tray by moving the lock DT1 to the left Figure 3 20 Unlocking the Disk Tray 4 Push the tray s button DT4 to open the tray handle Figure 3 21 Opening the Disk Tray 5 Grab the tray handle and pull it evenly towards you Figure ...

Страница 100: ...ten the screws one after the other Figure 3 23 Mounting the Drive in the Disk Tray 7 Insert the tray into the disk bay until the drive engages with the connector on the SAS backplane Now close the handle and lock the tray by pushing the lock DT1 to the right 8 Close the front cover 3 3 4 2 M 2 SSD Note You need A PH1 screw driver A standard M 2 SSD 1 M 2 mounting screws included in the unit 1 Remo...

Страница 101: ...er removing the top cover follow the instructions below for DIMM installation 1 Double check that the DIMMs be installed match the requirements of section 2 4 6 and make sure you follow the DIMM population rules given in that section 2 Open the white latches on the left and right sides of the DIMMs by turning it outwards as indicated by the arrows below Figure 3 28 Opening DIMM Latches 3 Select DI...

Страница 102: ...4 Insert the DIMM from the top using the guide rails on the left and right of the DIMM sockets Figure 3 30 DIMM Insertion into Slide Rails 5 Put your thumbs near the right and left end of the DIMM and press down the DIMM evenly until the white latches fully close with a click Figure 3 31 Seating the DIMM in the Socket 6 In case you want to install another DIMM repeat steps 1 to 5 accordingly ...

Страница 103: ...s as a pre configured system with CPUs and memory installed Installing CPUs requires trained personal special tools and a full production environment In the unlikely case that you need to install CPUs by yourself please contact your Advantech representative as product warranty may be impacted For a basic overview on the CPU installation procedure tools and challenges please refer to intel s docume...

Страница 104: ... that time There are three components subject to firmware upgrades in the SKY 8101S Component 0 BMC boot loader Component 1 BMC application firmware Component 2 FPGA Component 3 System BIOS Component 4 NVRAM Caution Please note that the BMC boot loader is a hardened and minimized firmware component which is not subject to field updates as it does not support fail safe updates via rollback capabili...

Страница 105: ...ilter with an angle of approximate 45 away from the bezel and then remove the air filter Figure 3 32 Air Filter Assembly To install the air filter insert the air filter with an angle of approximate 45 the bezel and press the air filter downward After inserting the air filter tighten the four M3 screws 3 5 2 PSU Modules Note You need no special tools A spare PSU module To replace a PSU module proce...

Страница 106: ...se of the installation procedure in Section 3 3 4 1 1 Open the front cover 2 Unlock the tray by moving the lock DT1 to the left Push the tray s black button DT4 to open the tray handle 3 Grab the tray handle and pull it evenly towards you 4 Remove the 2 5 drive mounting screws 5 Install a new HDD by following the instructions in Section 3 3 4 1 3 5 3 2 M 2 SSD Note You need A PH1 screw driver A st...

Страница 107: ...ration you need to remove the top cover PCIe card cages and the stiffener plate as described earlier To replace a DIMM module basically extract the DIMM module by pushing the DIMM socket latches outward As the latches flip completely open the DIMM module will be automatically extracted from the socket Pull the DIMM module out vertically Figure 3 34 Unlocking and Removing a DIMM To insert a new DIM...

Страница 108: ...____________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 106 Chapter 4 Tips Tricks and Troubleshooting ...

Страница 109: ...____________________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 107 ...

Страница 110: ..._________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 108 Appendix A Connector Pinout and LED Information ...

Страница 111: ... from BMC via USB to UART Transceiver CP2102 This connector can be found at below position Figure A 1 Micro USB Micro B connector for Console Port Table A 1 Micro USB Micro B connector Pin Assignment Pin No Signal Name Description 1 Power USB Power 5V 2 D The negative side of the differential pair that is used to transmit Data Address Command signals 3 D The positive side of the differential pair ...

Страница 112: ... I O panel These connectors can be found at below positions Figure A 2 USB Type A Connector Table A 2 USB 3 0 Type A Connector Pin Assignment or Pin Assignment Pin No Signal Name Description 1 Power USB Power 5V 900mA Fused 2 D USB 2 0 Differential Pair Signals 3 D 4 GND Digital Circuit Ground 5 SSRX USB3 0 SuperSpeed Receiver Differential Pair Signals 6 SSRX 7 GND_DRAIN Digital Circuit Ground for...

Страница 113: ...Connector Pin Assignment Pin No Signal Name Description 1 ML_Lane 0 p Main Link Singnal 0 P 2 GND Ground 3 ML_Lane 0 n Main Link Singnal 0 N 4 ML_Lane 1 p Main Link Singnal 1 P 5 GND Ground 6 ML_Lane 1 n Main Link Singnal 1 N 7 ML_Lane 2 p Main Link Singnal 2 P 8 GND Ground 9 ML_Lane 2 n Main Link Singnal 2 N 10 ML_Lane 3 p Main Link Singnal 3 P 11 GND Ground 12 ML_Lane 3 n Main Link Singnal 3 N 1...

Страница 114: ...___________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 112 19 Return Power Return Signal GND for Box to Box DisplayPort connecter 20 DP_PWR Power for Box to Box DisplayPort connecter ...

Страница 115: ...1 VeeT Module Transmitter Ground 2 Tx_Fault Module Transmitter Fault 3 Tx_Disable Transmitter Disable Turns off transmitter laser output 4 SDA 2 wire Serial Interface Data Line 5 SCL 2 wire Serial Interface Clock 6 Mod_ABS Module Absent 7 RS0 Rate Select 0 optionally controls SFP module receiver 8 Rx_LOS Receiver Loss of Signal Indication 9 RS1 Rate Select 1 optionally controls SFP module transmit...

Страница 116: ...n Inverted Data Input 19 TD Transmitter Inverted Data Input 20 VeeT Module Transmitter Ground Pin No Signal Name Description Pin No Signal Name Description C6 GND Circuit Ground D6 GND Circuit Ground C7 TX3_P Transmit Pair 3 D7 TX2_P Transmit Pair 2 C8 TX3_N D8 TX2_N C9 GND Circuit Ground D9 GND Circuit Ground Table A 5 SFP Connector LED Indication Speed LED Left Green Amber Color Link Active LED ...

Страница 117: ...ble A 6 RJ45 10 100 1000Base T Connector Pin Assignment Pin No Signal Name Description 1 MDI 0 Media Dependent Interface 0 2 MDI 0 Media Dependent Interface 0 3 MDI 1 Media Dependent Interface 1 4 MDI 2 Media Dependent Interface 2 5 MDI 2 Media Dependent Interface 2 6 MDI 1 Media Dependent Interface 1 7 MDI 3 Media Dependent Interface 3 8 MDI 3 Media Dependent Interface 3 A 5 2 LED Definition Tabl...

Страница 118: ...____________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 116 Appendix B BIOS POST Code ...

Страница 119: ... microcode loading 0x05 Unused 0x06 Microcode loading 0x07 AP initialization after microcode loading 0x08 North Bridge initialization after microcode loading 0x09 South Bridge initialization after microcode loading 0x0A Unused 0x0B Cache initialization 0x0E Microcode not found 0x0F Microcode not loaded 0x10 PEI Core is started 0x11 Pre memory CPU initialization is started 0x12 Pre memory CPU initi...

Страница 120: ...nitialization Programming memory timing information 0x2E Memory initialization Configuring memory 0x2F Memory initialization other 0x30 Reserved for ASL 0x31 Memory Installed 0x32 CPU post memory initialization is started 0x33 CPU post memory initialization Cache initialization 0x34 CPU post memory initialization Application Processor s AP initialization 0x35 CPU post memory initialization Boot St...

Страница 121: ...y initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecified memory initialization error 0x55 Memory not installed 0x56 Invalid CPU type or Speed 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU micro code is not found or m...

Страница 122: ...F North Bridge DXE initialization North Bridge module specific 0x70 South Bridge DXE initialization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x72 South Bridge DXE Initialization South Bridge module specific 0x73 South Bridge DXE Initialization South Bridge module specific 0x74 South Bridge DXE Initialization South Bridge module specifi...

Страница 123: ...devices connect 0x99 Super IO Initialization 0x9A USB initialization is started 0x9B USB Reset 0x9C USB Detect 0x9D USB Enable 0xA0 IDE initialization is started 0xA1 IDE Reset 0xA2 IDE Detect 0xA3 IDE Enable 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL 0xAB Setup Input Wait 0xAC Reserv...

Страница 124: ...ror 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found 0xD7 No Console Input Devices are found 0xD8 Invalid password 0xD9 Error loading Boot Option LoadImage returned error 0xDA Boot Op...

Страница 125: ...___________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 123 POST Code Description 0xE9 S3 Resume PPI not Found 0xEA S3 Resume Boot Script Error 0xEB S3 OS Wake Error 0xF0 0xF4 Unused 0xf8 0xFA Unused ...

Страница 126: ...______________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 124 Appendix C Power Supply Specification ...

Страница 127: ...tion Comment Conditions Input Voltage Rated 100Vrms 240Vrms AC 50 60Hz Min Max 90Vrms 264V rms AC 47Hz 63Hz Rating 700W Input Current 9 4A Inrush Current When input power is applied to the power supply any initial current surge or spike of 10ms or less will not exceed 25A peak Efficiency 90 20 load 230V 94 50 load 230V 91 100 load 230V Platinum Level Climate Saver 3 MTBF 1 50 000 hours at 100 load...

Страница 128: ...ications 1 UL 2 C UL 3 TUV 4 CCC 5 CB 6 CISPR Class A 7 FCC Class A 8 CE criteria B for power supply itself 9 RoHS Full ROHS lead free 6 6 10 Efficiency 80PLUS Platinum 230V Single Output 11 Immunity to meet ITE machine category on EN61000 4 X 12 BSMI 13 NEBS GR 1089 Surge Immunity L N 6KV L N FG 6KV Class A Compliance Protection Input Brown Out Input Surge Input Transient Output Over voltage Outp...

Страница 129: ...l inrush current surges or spikes in the form of DC cycles or multiple DC cycles greater than 10ms and less than 150ms must not exceed 20A peak Efficiency 90 100 load 48Vdc 92 50 load 48Vdc 88 20 load 48Vdc Without fan power MTBF 1 100 000 hours at 100 load and 50 degree C 2 150 000 hours demonstrated at 100 load and 35 degree C Environmental temperature at 25 degrees Celsius with normal operation...

Страница 130: ...S lead free 6 6 9 Immunity to meet ITE machine category on EN61000 4 X 10 REACH 11 Regulatory requirement Meet UL 60950 1 2nd Edition 2014 and CSA C22 2 No 60950 1 07 2nd Edition 2014 10 IEC 60950 1 2005 Second Edition Am 1 2009 Am 2 2013 IEC 61000 4 2 2008 IEC61000 4 3 2006 A1 20 07 A2 2010 IEC 61000 4 4 2014 IEC61000 4 5 2006 IEC61000 4 6 2008 IE C61000 4 8 2009 EN55032 2012 EN55024 2010 CISPR22...

Страница 131: ..._______________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 129 Appendix D Declaration of Conformity ...

Страница 132: ...are used for external wiring FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and i...

Страница 133: ...___________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 131 Appendix E Warranty and RMA ...

Страница 134: ...anty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered for example Advantech products used other hardware and software used etc Note anything abnormal and list...

Страница 135: ..._______________________________________________________________________________________________ SKY 8101S Manual V04 20180321 Copyright 2016 Advantech Co Ltd All rights reserved Page 133 Appendix F Glossary ...

Страница 136: ...hip IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface LOM Lights Out Management MAC Media Access Control MTBF Mean Time Between Failures NIC Network Interface Controller NMC Network Mezzanine Card NVRAM Non volatile Random Access Memory OOS Out Of Service PCH Platform Controllers Hub PCIe PCI Express PECI Platform Environment Control Interface PCI SIG P...

Страница 137: ...ech Co Ltd All rights reserved Page 135 SATA Serial Advanced Technology Attachment SCSI Small Computer System Interface SDR Sensor Data Record SerDes Serializer Deserializer SOL Serial Over LAN SSD Solid State Disk SW Software TPM Trusted Platform Module TX Transmit UDIMM Unbuffered DIMM UHCI Universal Host Controller Interface USB Universal Serial Bus ...

Страница 138: ...fications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permission of the publisher All brand and product names are trademarks or registered trademarks of their respective c...

Отзывы: