PCI-1241/1242 User Manual
94
• Load current: 400mA
• Off-state leakage current: 1uA Max.
• Turn-ON time: 2ms Max.
• Turn-OFF time: 0.2 ms Max.
• Arc-Free with no snubbing circuits
• Isolation: 1500Vrms
• Power requirements: E5V: DC+5V (4.8V~5.5V) ---500 mA
Please refer to following table for the effective Remote IO distance. Since
the effective distance is related to the communication base frequency,
users can configure the base frequency with function API
EP_SetRIOClockDivider before working with the remote IO modules.
Note:
If the voltage of E5V is less than +4.8 V, the
PCLD-8241 will not work properly.
Communication Base Frequency (Hz)
250 K
500 K 1 M 2 M
Effective Distance (Meter)
100
40
10
5