SNMP Management Module User Manual

12

Refer to your application's documentation for information on how MIB files are inte

-

grated when not using iView. MIBs II are based on standard RFC 1213. 

3.3

iView² (Webserver Version)

iView² is also available as a Webserver version. This is a browser-based software,

 

which can be downloaded from the Advantech website. It offers more features than

 

the Desktop version, such as supporting hundreds of users and particular Advantech

 

manageable fiber devices. It still offers MIBs II and levels of security. 
Refer  to  the  “

Getting  Started” 

and  “

Installation  Instructions” 

documents  that  are

 

included with the Webserver download in the zip file, posted on the website. 

3.4

UMA (Unified Management Agent)

Centralized management makes practical sense for networks of all sizes, especially

 

service provider networks that must monitor and upgrade large quantities of devices.

 

The Unified Management Agent (UMA) allows operators to manage all modules with

 

Flash  PROM  (FiberLinX-II  series)  installed  in  an Advantech  iMediaChassis  series,

 

with a single IP address from a central location. In addition, UMA allows users to cen

-

trally manage and administer firmware upgrades over multiple devices. 
For example, install 20 iMcV-FiberLinX-II devices in a 20-slot iMediaChassis at the

 

Central Office (CO) then connect each to a remote iMcV-FiberLinX-II unit installed at

 

the  customer’s  premise  (CPE);  UMA  will  then  allow  users  to  manage  all  devices

 

(including the chassis at the CO) via a single IP address. Users may still assign IP

 

addresses  to  each  iMcV-FiberLinX-II  and  manage  them  independently  when  the

 

SNMP Management Module within the iMediaChassis is omitted. 
When an SNMP request for an iMcV-FiberLinX-II comes in, the SNMP Management

 

Module in the iMediaChassis series passes the request to the SNMP agent  in the

 

specific  module.  The  SNMP  agent  in  the  iMcV-FiberLinX-II  provides  the  relevant

 

management information, which is then routed via the SNMP Management Module

 

and supplied to the client GUI (iView², version 1.8 or higher), as well as the serial port

 

and Telnet. 

3.5

Easy Upgrades with the Unified Management 

Agent (UMA) 

Upgrade one or multiple Host (CO) or Remote (CPE) devices with just a few 

mouse clicks. Refer to the iMcV-FiberLinX-II, iMcV-GigaFiberLinX, and IE-Mini 

FiberLinX-II series manuals for complete information. 

All devices in chassis are fully functional while upgrades are in process. 

Manage up to 41 devices with a single IP address. 

Only one Ethernet port is required, reducing the number of ports used on a net

-

work switch. 

3.6

iView Passwords

Passwords are a way to make the management of network devices secure. If pass

-

word accesses are lost, contact Advantech Technical Support.

Содержание IMC-710-A

Страница 1: ...User Manual SNMP Management Module IMC 710 A ...

Страница 2: ...oper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be bi...

Страница 3: ...s uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advan...

Страница 4: ...e comments and constructive criticism Please send all such in writing to ICG Support advantech com Warning Important safety instructions save these instructions this manual con tains important safety instructions Caution For use in a controlled environment Refer to manual for environmental conditions Note Notes provide optional additional information ...

Страница 5: ...e publié par le ministère des Communications du Canada Electrostatic Discharge ESD Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an...

Страница 6: ...d 60950 1 Certified to CSA Std C22 2 No 60950 1 European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked th...

Страница 7: ...ction 5 2 1 Web HTTP 6 2 2 Serial Port Configuration 6 2 3 Using Telnet 6 2 4 Using DHCP 7 2 4 1 DHCP Disable Static IP Addressing 7 2 4 2 DHCP Enable Dynamic IP Addressing 7 2 5 Main Serial Telnet Configuration Screen 7 Chapter 3 iView2 Software Installation 10 3 1 Overview 11 3 2 Using iView 11 3 2 1 System Requirements 11 3 2 2 Other NMS Applications 11 3 3 iView Webserver Version 12 3 4 UMA Un...

Страница 8: ...SNMP Management Module User Manual viii List of Figures Figure 1 1 Front View 3 Figure 1 2 System LED 3 ...

Страница 9: ...Chapter 1 1Product Overview ...

Страница 10: ...anagement Module connects to the LAN via an external 10 100 twisted pair connection Connect the chassis to the network by plugging one end of a CAT 5 twisted pair cable into the port labeled MGMT on the Management Module Plug the other end of the cable into a device e g switch etc in the existing Ethernet network 1 2 Specifications Intended for indoor and outdoor use Note Some options require item...

Страница 11: ...all application modules such as media conversion and mode conversion modules in this slot No Item Description 1 MGMT RJ45 port for remote management 2 Option ETH 10 100BaseT X port 3 Console Console cable port to COM port DB9 male on computer to RS232 managed switch RJ45 female 1 2 3 No Item Description 1 Temp Glows yellow when temperature of unit surpasses a user defined level configurable throug...

Страница 12: ... of the SNMP management board s configuration 3 If the SNMP Management Module needs to be replaced set the SNMP Write Lock switch to LOCKED 4 Remove the old SNMP module and replace with another SNMP module 5 Connect to this SNMP module via Web HTTP Select Tools Upgrade Manager on menu 6 Select HTTP on Upgrade Method and select Startup configuration on Upgrade type 7 Find path of configuration file...

Страница 13: ...Chapter 2 2Web HTTP Function ...

Страница 14: ...this manual for additional information 2 2 Serial Port Configuration SNMP Management Modules used with the iMediaChassis series feature a serial port that includes a DB 9 serial connector To connect an iMediaChassis series to a terminal computer use a straight through pin to pin cable If the computer terminal s port is not compatible with a DB 9 COM port use the pin connection chart for reference ...

Страница 15: ...al Telnet Configuration Screen After launching a serial session using a CLI Command Line Interface or a TELNET session an initial self test is performed and the main screen will display the following message Welcome to SNMP Management Module and ready to accept user account password 2 5 0 1 Assigning IP Information To modify the saved parameter values i e assign IP address and subnet mask key comm...

Страница 16: ...er 2 5 0 5 Removing Trap Destinations To remove specific trap destinations key in configure to enter configuration mode and key in no snmp host x x x x traps x x x x is Ip address and press enter to delete 2 5 0 6 Enabling Disabling DHCP To Enable Disable DHCP Key in configure to enter configuration mode and key in no ip dhcp and press enter to enable disable DHCP 2 5 0 7 Ending a Session When end...

Страница 17: ...9 SNMP Management Module User Manual ...

Страница 18: ...Chapter 3 3iView2 Software Installation ...

Страница 19: ...dvantech intelligent networking devices It features a GUI that provides network managers the ability to monitor and control Advantech products The application is available as a free download from the website iView Webserver version requires the following MySQL ver 5 1 or higher Apache TomCat 6 or greater JAVA ver 1 7 or greater Browsers required MS Internet Explorer ver 10 or greater Mozilla Firef...

Страница 20: ...ces in a 20 slot iMediaChassis at the Central Office CO then connect each to a remote iMcV FiberLinX II unit installed at the customer s premise CPE UMA will then allow users to manage all devices including the chassis at the CO via a single IP address Users may still assign IP addresses to each iMcV FiberLinX II and manage them independently when the SNMP Management Module within the iMediaChassi...

Страница 21: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2021 ...

Отзывы: