![Advantech IMC-710-A Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/advantech/imc-710-a/imc-710-a_user-manual_3048073014.webp)
SNMP Management Module User Manual
6
2.1
Web-HTTP
Web-HTTP can let users quickly and easily complete the first stages of SNMP
configuration for SNMP-manageable devices. Web-HTTP can set the IP address,
subnet mask and default gateway as well as define the community strings and SNMP
traps.
The Web-HTTP can be used to upload new versions of the system software and new
MIB information. It also offers diagnostic capabilities for faster resolution of technical
support issues. The default user ID for both Web-HTTP and Telnet is:
User: admin / Password: admin
The two levels of Telnet account access are:
User: Can only see status, change password and reboot.
Administrator: Can perform all functions and add/delete accounts and perform
the command reset.
A Username and Password can be added in the User Account of Tools, or the
Accounts command within Telnet or the Serial Configuration. Admin/admin should
not be deleted until new usernames/passwords are tested. Refer to the Password
section of this manual for additional information.
2.2
Serial Port Configuration
SNMP Management Modules used with the iMediaChassis series feature a serial
port that includes a DB-9 serial connector. To connect an iMediaChassis series to a
terminal/computer, use a straight-through (pin-to-pin) cable. If the computer/
terminal’s port is not compatible with a DB-9 COM port, use the pin connection chart
for reference in making a cable.) Make sure the cable length is less than 15.24
meters (50 ft). Plug one end of the cable into the DB-9 connector and the other into
the appropriate port on the computer/terminal.
Set the computer/terminal for VT-100 emulation. The serial port on the computer/
terminal should be set for: 38.4K baud, 8 data bits, 1 stop bit, no parity, no flow
control. The F2 key functions as a Delete key on VT-100 emulators.
Serial Adapter Pin Connection
2.3
Using Telnet
The iMediaChassis series supports Telnet for remote configuration. All configurations
that can be performed via the serial port can also be performed using Telnet (except
serial passwords). Use only one Telnet session at a time.
RJ-45 Pi n #
DB-9 Pin #
Function
5
2
Transmit (OUT)
7
3
Receive (IN)
8
5
Ground
1-4, 6
1, 4, 6-9
Reserved
Содержание IMC-710-A
Страница 1: ...User Manual SNMP Management Module IMC 710 A ...
Страница 9: ...Chapter 1 1Product Overview ...
Страница 13: ...Chapter 2 2Web HTTP Function ...
Страница 17: ...9 SNMP Management Module User Manual ...
Страница 18: ...Chapter 3 3iView2 Software Installation ...