Advantech IMC-710-A Скачать руководство пользователя страница 2

SNMP Management Module User Manual

ii

Copyright

The documentation and the software included with this product are copyrighted 2021

 

by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right

 

to make improvements in the products described in this manual at any time without

 

notice. No part of this manual may be reproduced, copied, translated or transmitted

 

in any form or by any means without the prior written permission of Advantech Co.,

 

Ltd.  Information  provided  in  this  manual  is  intended  to  be  accurate  and  reliable.

 

However, Advantech  Co.,  Ltd.  assumes  no  responsibility  for  its  use,  nor  for  any

 

infringements of the rights of third parties, which may result from its use.

Acknowledgements

Intel and Pentium are trademarks of Intel Corporation.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.

Product Warranty (5 years)

Advantech warrants to you, the original purchaser, that each of its products will be

 

free from defects in materials and workmanship for five years from the date of pur

-

chase.
This warranty does not apply to any products which have been repaired or altered by

 

persons other than repair personnel authorized by Advantech, or which have been

 

subject to misuse, abuse, accident or improper installation. Advantech assumes no

 

liability under the terms of this warranty as a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing, most of

 

our customers never need to use our repair service. If an Advantech product is defec

-

tive, it will be repaired or replaced at no charge during the warranty period. For out of-

warranty repairs,  you will be billed according to the cost of replacement  materials,

 

service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:

1.

Collect all the information about the problem encountered. (For example, CPU 

speed, Advantech products used, other hardware and software used, etc.) Note 

anything abnormal and list any on screen messages you get when the problem 

occurs.

2.

Call your dealer and describe the problem. Please have your manual, product, 

and any helpful information readily available.

3.

If your product is diagnosed as defective, obtain an RMA (return merchandize 

authorization) number from your dealer. This allows us to process your return 

more quickly.

4.

Carefully pack the defective product, a fully-completed Repair and Replacement 

Order Card and a photocopy proof of purchase date (such as your sales receipt) 

in a shippable container. A product returned without proof of the purchase date 

is not eligible for warranty service.

5.

Write the RMA number visibly on the outside of the package and ship it prepaid 

to your dealer.

Edition 1

Printed in Taiwan

December 2021

Содержание IMC-710-A

Страница 1: ...User Manual SNMP Management Module IMC 710 A ...

Страница 2: ...oper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be bi...

Страница 3: ...s uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advan...

Страница 4: ...e comments and constructive criticism Please send all such in writing to ICG Support advantech com Warning Important safety instructions save these instructions this manual con tains important safety instructions Caution For use in a controlled environment Refer to manual for environmental conditions Note Notes provide optional additional information ...

Страница 5: ...e publié par le ministère des Communications du Canada Electrostatic Discharge ESD Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an...

Страница 6: ...d 60950 1 Certified to CSA Std C22 2 No 60950 1 European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked th...

Страница 7: ...ction 5 2 1 Web HTTP 6 2 2 Serial Port Configuration 6 2 3 Using Telnet 6 2 4 Using DHCP 7 2 4 1 DHCP Disable Static IP Addressing 7 2 4 2 DHCP Enable Dynamic IP Addressing 7 2 5 Main Serial Telnet Configuration Screen 7 Chapter 3 iView2 Software Installation 10 3 1 Overview 11 3 2 Using iView 11 3 2 1 System Requirements 11 3 2 2 Other NMS Applications 11 3 3 iView Webserver Version 12 3 4 UMA Un...

Страница 8: ...SNMP Management Module User Manual viii List of Figures Figure 1 1 Front View 3 Figure 1 2 System LED 3 ...

Страница 9: ...Chapter 1 1Product Overview ...

Страница 10: ...anagement Module connects to the LAN via an external 10 100 twisted pair connection Connect the chassis to the network by plugging one end of a CAT 5 twisted pair cable into the port labeled MGMT on the Management Module Plug the other end of the cable into a device e g switch etc in the existing Ethernet network 1 2 Specifications Intended for indoor and outdoor use Note Some options require item...

Страница 11: ...all application modules such as media conversion and mode conversion modules in this slot No Item Description 1 MGMT RJ45 port for remote management 2 Option ETH 10 100BaseT X port 3 Console Console cable port to COM port DB9 male on computer to RS232 managed switch RJ45 female 1 2 3 No Item Description 1 Temp Glows yellow when temperature of unit surpasses a user defined level configurable throug...

Страница 12: ... of the SNMP management board s configuration 3 If the SNMP Management Module needs to be replaced set the SNMP Write Lock switch to LOCKED 4 Remove the old SNMP module and replace with another SNMP module 5 Connect to this SNMP module via Web HTTP Select Tools Upgrade Manager on menu 6 Select HTTP on Upgrade Method and select Startup configuration on Upgrade type 7 Find path of configuration file...

Страница 13: ...Chapter 2 2Web HTTP Function ...

Страница 14: ...this manual for additional information 2 2 Serial Port Configuration SNMP Management Modules used with the iMediaChassis series feature a serial port that includes a DB 9 serial connector To connect an iMediaChassis series to a terminal computer use a straight through pin to pin cable If the computer terminal s port is not compatible with a DB 9 COM port use the pin connection chart for reference ...

Страница 15: ...al Telnet Configuration Screen After launching a serial session using a CLI Command Line Interface or a TELNET session an initial self test is performed and the main screen will display the following message Welcome to SNMP Management Module and ready to accept user account password 2 5 0 1 Assigning IP Information To modify the saved parameter values i e assign IP address and subnet mask key comm...

Страница 16: ...er 2 5 0 5 Removing Trap Destinations To remove specific trap destinations key in configure to enter configuration mode and key in no snmp host x x x x traps x x x x is Ip address and press enter to delete 2 5 0 6 Enabling Disabling DHCP To Enable Disable DHCP Key in configure to enter configuration mode and key in no ip dhcp and press enter to enable disable DHCP 2 5 0 7 Ending a Session When end...

Страница 17: ...9 SNMP Management Module User Manual ...

Страница 18: ...Chapter 3 3iView2 Software Installation ...

Страница 19: ...dvantech intelligent networking devices It features a GUI that provides network managers the ability to monitor and control Advantech products The application is available as a free download from the website iView Webserver version requires the following MySQL ver 5 1 or higher Apache TomCat 6 or greater JAVA ver 1 7 or greater Browsers required MS Internet Explorer ver 10 or greater Mozilla Firef...

Страница 20: ...ces in a 20 slot iMediaChassis at the Central Office CO then connect each to a remote iMcV FiberLinX II unit installed at the customer s premise CPE UMA will then allow users to manage all devices including the chassis at the CO via a single IP address Users may still assign IP addresses to each iMcV FiberLinX II and manage them independently when the SNMP Management Module within the iMediaChassi...

Страница 21: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2021 ...

Отзывы: