background image

ICR-2031

Serial communication is not working.

Verify that the router model supports serial communications. Also verify the serial
communication settings. To do so, open the router’s configuration menu via the
web browser, select the appropriate "Expansion Port" from "Configuration" part of
the menu and verify the settings.

Is the router Cisco compatible? Can I use the Cisco configuration?

No, the Firmware in the router (Conel OS) is based on Linux with BusyBox. Thus
the Cisco configuration cannot be used. But network connections are defined by
standards so connecting the router to the Cisco or other networking devices is pos-
sible and will be compatible.

FTP or SFTP does not work

FTP will work on v2 routers only. You can use SFTP on all routers to transfer files
to/from the router. If having troubles with FTP on v2 routers, make sure you have
FTP enabled: "Configuration" section, "Services", "FTP". Then you can connect
with any client on port 21 with name and password same as for the Web interface.
If having troubles with SFTP, make sure you have SSH enabled: "Configuration"
section, "Services", "SSH". Then you can connect with any client on port 22 with
name and password same as for the Web interface.

How can I connect to the router’s command line? (SSH, Telnet)

You can use SSH on all routers or Telnet on v2 routers only. SSH is enabled by
default, but you can verify in Web interface in "Configuration" section, "Services",
"SSH". Then connect with any SSH client on port 22 of the router. User and pass-
word is the same as for the Web interface. Telnet on v2 routers can be enabled
here: "Configuration" section, "Services", "Telnet".

31

Содержание ICR-2031

Страница 1: ...LTE Industrial Router ICR 2031 USER MANUAL ...

Страница 2: ...ect to change without notice and does not represent a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is for...

Страница 3: ...he router Attention Problems that can arise in specific situations Information notice Useful tips or information of special interest Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0057 EN revision from June 20 2023 Released in the Czech Republic ii ...

Страница 4: ...Card Slot 15 2 2 Antennas 16 2 3 Ethernet Interfaces 16 2 4 Power Supply 17 2 5 I O Port Interfaces 18 2 6 LED Status Indication 19 2 7 Reset Functions 20 3 First Use 21 3 1 Accessories Connection 21 3 2 Router Configuration 21 4 Technical Specifications 23 4 1 Basic Parameters 23 4 2 Standards and Regulations 24 4 3 Type Tests and Environmental Conditions 25 4 4 Parameters of Cellular Module 26 4...

Страница 5: ...ICR 2031 Appendix C Regulatory Safety Information 33 Appendix D Related Documents 35 iv ...

Страница 6: ...sions Top Side and Front View with DIN Rail Clip 10 7 Screwed Wall Mounting Clip 12 8 Position of the DIN Rail Clip 13 9 Removing Router from the DIN Rail 13 10 Product Label 14 11 SIM Card Insertion 15 12 Ethernet Connector Pinout 16 13 Connection of Power Supply 17 14 Position of the Grounding Screw 17 15 I O Connector Pinout 18 16 Functional Scheme of the Binary Interface 18 17 Resetting the Ro...

Страница 7: ... Pinout Description 16 6 Power Supply Pinout 17 7 I O Ports Pinout 18 8 LED Status Indication 19 9 Basic Parameters 23 10 Standards and Regulations 24 11 Type Tests and Environmental Conditions 25 12 Technical Parameters of Cellular Module 26 13 Technical Parameters of WiFi 27 14 Electrical Characteristics of Binary Input 28 15 System Configuration 28 1 ...

Страница 8: ... of the initial configuration it cannot be assembled to the router at some point in the future The router supports VPN tunnel creation using various protocols to ensure safe commu nications The router provides diagnostic functions which include automatic monitoring of the wireless and wired connections automatic restart in case of connection losses and a hard ware watchdog that monitors the router...

Страница 9: ...amples The router is primarily intended for these basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN II Backed up access to the Internet from LAN Figure 2 Backed up Access to the Internet 3 ...

Страница 10: ...ICR 2031 III Secure networks interconnection or using VPN Figure 3 Using VPN Tunnel 4 ...

Страница 11: ...ing screw M3 Pay attention to proper grounding see Chapter 2 4 2 PWR IN OUT 6 pin terminal Power supply binary input and binary output interfaces See Chapter 2 4 Chapter 2 5 for more information Chap ter 4 6 for I O parameters 3 WiFi RP SMA female Connector for the WiFi antenna see Chapter 2 2 and Chapter 4 5 for WiFi parameters 4 LEDs Status LED indication see Chapter 2 6 5 RST Button to reboot t...

Страница 12: ...ar module see Chapter 2 2 8 DIV SMA female Connector for the second antenna of the cellular module required for the MIMO DL see Chapter 2 2 9 SIM slot Micro SIM One SIM card slot see Chapter 2 1 10 DIN clip DIN rail clip not included as standard accessories see Chapter 1 10 11 Wall clip Wall mounting clip included as standard accessories see Chapter 1 9 Table 1 Hardware Overview of the Router 6 ...

Страница 13: ... Output 1x SIM reader WiFi Table 2 Order Codes Overview 1 5 Product Revisions For the product revision history see the table below The revision number is printed on the packaging and product labels The router GUI can also display the product revision under Status General System Information Product Revision Please note that the default revision Rev 1 0 is unavailable here Rev Description 1 0 Initia...

Страница 14: ...in the following table Item Description Figure Q ty 1 Router 1 pcs 2 Wall mounting clip with screws 1 set 3 6 pin terminal block for power sup ply digital input and digital output de ployed on the router 1 pcs 4 Printed Quick Start Guide Leaflet 1 pcs Table 4 Contents of Package 8 ...

Страница 15: ... Dimensions For the dimensions of the product see the figures below Note that all sizes are measured in millimeters Variant with Wall Mounting Clip Figure 5 Router Dimensions Top Side and Front View with Wall Mount Clip 9 ...

Страница 16: ...ICR 2031 Variant with DIN Rail Clip Figure 6 Router Dimensions Top Side and Front View with DIN Rail Clip 10 ...

Страница 17: ...outer attached to a switchboard For whip antennas it is recommended to observe a minimum distance of 6 cm from ca bles and metal surfaces on every side in order to avoid interference When using an external antenna separate from the switchboard it is necessary to fit a lightning conduc tor When mounting a router on sheet steel we recommend using a cable antenna For all cables we recommend to bind t...

Страница 18: ... to a wall or another surface using the wall mounting clip There are two wholes on the clip with a diameter of 4 millimeters For detailed information about the mounting dimensions see Figure 5 in Chapter 1 7 When mounting the wall mounting clip tighten the screws with max torque of 0 4 Nm Figure 7 Screwed Wall Mounting Clip 12 ...

Страница 19: ...ion of the clip is shown in Figure 8 When mounting the DIN rail clip tighten the screws with max torque of 0 4 Nm Figure 8 Position of the DIN Rail Clip To remove the router from the DIN rail it is necessary to lightly push down the router so that the bottom part of the DIN rail clip hitched to the DIN rail get out of this rail and then fold out the bottom part of the router away from the DIN rail...

Страница 20: ...ICR 2031 1 11 Product Label The figure below shows an example of the product labels with all the information printed on them Figure 10 Product Label 14 ...

Страница 21: ...Names adjusted The SIM card changing procedure is described below Enter the PIN in the router s web interface if the PIN is required for the SIM Administration Unlock SIM Card Type of SIM card Micro SIM 3FF 15 0 x 12 0 x 0 76 mm Inserting the SIM card Always disconnect the router from the power supply before handling the SIM card Unscrew two screws on the SIM card cover and remove the cover To rem...

Страница 22: ...mmended tightening moment for screwing the antenna to the SMA female connectors is 0 9 Nm 2 3 Ethernet Interfaces The maximum length of the cables connected to the Ethernet ports is 30 meters to meet the EMC immunity conditions The panel socket of RJ45 is used for Ethernet interface The pinout of the socket is shown in Figure 12 and described in Table 5 Figure 12 Ethernet Connector Pinout Pin Sign...

Страница 23: ...e router is between 9 V and 48 V DC see the connection scheme on Figure 13 Protection against reversed polarity without signaling is built into the router For correct operation it is necessary that the power source is able to supply a peak current of 1 A Unit has to be supplied by a power supply specified as a Limited Power Source LPS or CEC NEC Class 2 source of supply The metal case of the route...

Страница 24: ...scribed in Table 7 Figure 15 I O Connector Pinout Pin Signal mark Description 3 IN The binary input positive pole 4 IN The binary input negative pole 5 OUT The binary output positive pole 6 OUT The binary output negative pole Table 7 I O Ports Pinout The I O user interface is designed for binary input processing and binary output control For detailed electrical parameters see Chapter 4 6 The funct...

Страница 25: ...ve DO Green On The binary output is active DAT Green Blinking Cellular communication is in progress SIG Green On Blinking Fast blinking Good cellular signal Fair cellular signal Poor cellular signal TECH Green On Blinking Fast blinking The active SIM uses 4G technology The active SIM uses 3G technology The active SIM uses 2G technology SIM Green On Fast blinking SIM is active for the cellular conn...

Страница 26: ...configuration of the router press and hold the RST button for more than 4 seconds After that the PWR LED turns off and on again We recommend holding the RST button for 1 second after turning on the PWR LED Emergency Factory Reset If the router cannot boot up due to the incorrect configu ration turn off the router disconnect the power supply Then push and hold the RST button turn on the router and ...

Страница 27: ...192 168 1 1 address in a web browser Please note that usage of the HTTPS protocol for secure communication over the network is required There is just the root user account created on the router by default See the product label on the router for its default password1 Log in to the web interface with the root user and his password If logged in successfully the user will have access to the router web...

Страница 28: ...ICR 2031 Figure 18 Router s Web Interface A detailed description of the router settings in the web interface can be found in the configura tion manual 1 of the router 22 ...

Страница 29: ...DC Battery for RTC CR2032 CR12251 Consumption for non WiFi WiFi version Idle Average Maximum 1 8 W 2 1 W 2 8 W 3 6 W 3 3 W 4 0 W Dimensions of device w o clip 103 95 25 mm 4 06 3 74 0 98 DIN rail clip optional part specification DIN 35 mm EN 60715 Weight Box w o clip 335 g 0 74 lbs Antenna connectors ANT DIV WiFi SMA female connectors for LTE 50 Ω RP SMA female connector for WiFi 50 Ω Interfaces E...

Страница 30: ... 13 EMC EN 301 489 1 EN 301 489 17 EN 301 489 52 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 IEC 61000 6 2 IEC 61000 6 3 EN 55032 Safety EN IEC 62368 1 UL E4877201 IEEE 802 3 Transportation E Mark E8 homologation number 10R 06 140281 National CE UKCA compliant Environmental REACH RoHS3 and WEEE compliant Table 10 Standards and Regulations 1 For product revision 2 0 and higher ...

Страница 31: ...onducted EN 61000 4 6 DC port ETH I O ports 10 V 0 15 80 MHz 80 AM 1kHz L3 10 V 0 15 80 MHz 80 AM 1kHz L3 10 V 0 15 80 MHz 80 AM 1kHz L3 Radiated emission EN 55032 Enclosure Class B 30 MHz 1 GHz 1 GHz 6 GHz Conducted emission EN 55032 DC power port Ethernet ports Class B 150 kHz 30 MHz Class B 150 kHz 30 MHz Dry heat EN 60068 2 2 Operating Storage Test Bb storage 75 C Test Bd operation 85 C Cold E...

Страница 32: ...Hz B7 2600 MHz B3 1800 MHz B1 2100 MHz TDD frequencies B41 2500 MHz B40 2300 MHz B38 2600 MHz Bit rates up to 150 Mbps DL 50 Mbps UL HSPA UMTS parameters Supported frequencies B8 900 MHz B1 2100 MHz Bit rates up to 42 Mbps DL 5 76 Mbps UL EDGE GPRS parameters Supported frequencies B8 900 MHz B3 1800 MHz Bit rates up to 296 kbps DL 236 8 kbps UL Table 12 Technical Parameters of Cellular Module 26 ...

Страница 33: ... US Canada and EU 5 25 5 35 GHz FCC UNII middle band for US Canada and EU 5 47 5 725 GHz for EU 5 725 5 825 GHz FCC UNII high band for US Canada Modulation DSSS OFDM DBPSK DQPSK CCK 16 QAM 64 QAM 2 4 GHz Channels 1 2 3 4 5 6 7 8 9 10 11 12 13 5 GHz Channels 36 38 40 42 44 46 48 52 56 60 64 100 104 108 112 116 120 124 128 132 136 140 149 153 157 161 165 Type of Device Access point AP Station STA Mu...

Страница 34: ...s 0 0 8 V 0 5 mA On 1 2 V Off Table 14 Electrical Characteristics of Binary Input The maximum binary output load is 100 mA at 9 48 V 4 7 System Configuration The main parametes of the system are listed in Table 15 Parameter Description CPU architecture ARM926EJ S CPU frequency 600 MHz CPU power 4 72 DMIPS MHz Flash memory 64 MB NOR Flash 12 MB for Router Apps 2 MB for customer data RAM size 128 MB...

Страница 35: ... the neighbouring cells have a similar signal strength you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable automatic ping from the router which will check the connection when there are no data running and in the case of a failed ping restart the connection This can be done on the Mobile WAN Configuration page in the router in the Check co...

Страница 36: ...e with router s IP address You can verify a Firewall by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the System Log DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server ...

Страница 37: ...ers only You can use SFTP on all routers to transfer files to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can conne...

Страница 38: ...eu Web www advantech com Customer Support for NAM Advantech B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 1 815 433 5109 E mail support advantech bb com Web www advantech bb com Customer Support for Asia Phone 886 2 2792 7818 1299 Monday Friday 9 a m to 5 30 p m UTC 8 Fax 886 2 2794 7327 E mail icg support advantech com tw Web www ad...

Страница 39: ... expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature Only routers with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the...

Страница 40: ...inimize the environmental impact This product contains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains a battery Re move the battery from the device before disposal The battery in the device needs to be disposed of apart accordingly Check the terms and conditions of your...

Страница 41: ...CR 2031 Appendix D Related Documents 1 ICR 2 0456 00 Configuration Manual EP Product related documents and applications can be obtained on Engineering Portal at https icr advantech cz download address 35 ...

Страница 42: ...lies with Directive 2014 53 EU We Advantech Czech s r o declare that the radio equipment narrated in this user s manual complies with Radio Equipment Regulations 2017 S I 2017 No 1206 The full text of the EU Declaration of Conformity is available at the following internet address icr advantech cz eudoc ...