FWA-1320 User Manual

20

Figure 2.7 DIMM Location

DIMM modules can be populated in any order.  DDR3 and DDR3L modules differ in
some operating voltages and will be recognized automatically. No manual adjustment
is  required.  However, mixing  DDR3  and  DDR3L  DIMMs  is  not  supported and can
lead to system damage.
It is recommended to use identical DIMMs on both sockets for best performance and
reliability.
The following list summarizes the modules validated on the FWA-1320:

Please  contact  you  Advantech  representative  for  the  most  recent  list  of  validated
peripherals or if you would like to use modules not listed.

Table 2.7: DIMM Mapping

Location

DIMM

Channel

Color

SMBus Adr.

D1

1

A

Black

0xA0

D2

2

A

Amber

0xA2

Table 2.8: Validated DIMMs

Vendor

Frequency

Capacity

Advantech PN

Apacer

DDR3-1333

2G

96D3-2G1333NN-AP1

DDR3-1600

96D3-2G1600NN-APL

DDR3-1333

4G

96D3-4G1333NN-AP

DDR3-1333

96D3-4G1333E-AP

DDR3-1600

8G

96D3-8G1600NN-APL

DDR3-1333

96D3-8G1333NN-APL

DDR3-1600

96D3-8G1600E-APL

Transcend

DDR3-1600

2G

96D3-2G1600NN-TRL

DDR3-1600

4G

96D3-4G1600NN-TR

DDR3L-1600

AQD-D3L4GN16-SQ

Advantech

DDR3L-1600

2G

AQD-D3L2GN16-SQ

DDR3L-1600

4G

AQD-D3L4GN16-MG

DDR3L-1600

AQD-D3L4GN16-SG

DDR3L-1600

AQD-D3L4GN16-MQ

DDR3L-1600

8G

AQD-D3L8GN16-SG

Содержание FWA-1320

Страница 1: ...User Manual FWA 1320 TABLETOP NETWORK APPLIANCE BASED ON INTEL ATOM C2000 SYSTEM ON CHIP ...

Страница 2: ...d or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Atom QuickAssist and Intel are trademarked by Intel C...

Страница 3: ...cument Useful documents If you cannot find the information you re looking for or need more detailed information on a specific topic please refer to the list of additional documents and other sources of information below Please contact your Advantech representative if you need help on obtaining these documents or still can t find what you re looking for Advanced LAN Bypass User Manual Information o...

Страница 4: ...form Management HWM Hardware Monitor chip IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface LOM Lights Out Management MAC Media Access Control MTBF Mean Time Between Failures NIC Network Interface Controller NMC Network Mezzanine Card NVRAM Non volatile Random Access Memory OOS Out Of Service PCH Platform Controllers Hub PCIe PCI Express PECI Platform E...

Страница 5: ...tem Interface SDR Sensor Data Record SerDes Serializer Deserializer SOL Serial Over LAN SSD Solid State Disk SW Software TPM Trusted Platform Module TX Transmit UDIMM Unbuffered DIMM UHCI Universal Host Controller Interface USB Universal Serial Bus ...

Страница 6: ...FWA 1320 User Manual vi ...

Страница 7: ...e Product Versions 15 2 3 Technical Specifications 15 Table 2 3 Specifications 15 2 3 1 System dimensions 16 Figure 2 2 System Dimensions 16 2 3 2 Regulatory Compliance 16 Table 2 4 Applicable Safety Regulations 16 Table 2 5 Applicable EMC Regulations 17 2 4 Detailed Description 17 2 4 1 Front Elements 17 Figure 2 3 System Front View 17 Table 2 6 Front Elements 17 Figure 2 4 Front LEDs 18 2 4 2 Sy...

Страница 8: ...Main screen 37 Figure 3 5 Advanced Setup Console Redirection Menu 37 Figure 3 6 Advanced Setup COM1 Console Redirection Sub menu 38 Table 3 2 Advanced Setup COM1 Console Redirection Menu Items 38 Figure 3 7 Advanced Setup PCI Subsystem 39 Table 3 3 Advanced Setup PCI Subsystem Menu Items 40 Figure 3 8 Advanced Setup Network Stack Configuration Menu 40 Table 3 4 Network Stack Configuration Menu 41 ...

Страница 9: ...nsertion into slide rails 60 Figure 3 33Seating the DIMM in the socket 60 3 4 Firmware Upgrades 61 3 4 1 BIOS 61 3 4 2 LAN Bypass 61 3 5 Replacing FRUs 61 3 5 1 Disk drives 61 3 5 2 CMOS Battery 62 Figure 3 34Unlocking the battery 62 Figure 3 35Battery Polarity 63 3 5 3 DIMMs 63 Figure 3 36Unlocking and removing a DIMM 63 Appendix A Connector Pinout and LED Information65 A 1 Console Port RS232 66 ...

Страница 10: ...FWA 1320 User Manual x C 1 Declaration of Conformity 76 C 1 1 CE 76 C 1 2 FCC Class A 76 Appendix D Warranty and RMA 77 D 1 Warranty and RMA 78 ...

Страница 11: ...Chapter 1 1 Getting Started ...

Страница 12: ...te the knowledge of a specialist and must not be used as replacement for qualified personnel Operating personnel must not remove equipment covers Only factory authorized service personnel or other quali fied service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment Do not install substitute parts or perform any unauthorized modificat...

Страница 13: ...harm and the products from dam age 1 Be sure you are at an ESD workstation or grounded with an ESD strap before opening the top cover or installing removing any unit accessible from the out side Doing so will discharge any static electricity that might have built up in your body 2 Don t touch any components inside the system while the system is on 3 Disconnect power before making any configuration...

Страница 14: ...rence Other terminal programs may be used in a similar way as well Open up PuTTY and begin the configuration as shown below Please use the actual COM port s number on the client machine instead of COM1 Specify COM1 under serial line and 115200 for speed no parity no flow con trol Check Serial for connection type Check VT100 for keypad in the keyboard submenu Check Colour or Both for Indicate bolde...

Страница 15: ...5 FWA 1320 User Manual Chapter 1 Getting Started Figure 1 1 PuTTY Session Configuration Figure 1 2 PuTTY Serial Configuration ...

Страница 16: ...FWA 1320 User Manual 6 Figure 1 3 PuTTY Keyboard Settings Figure 1 4 PuTTY Colour Settings ...

Страница 17: ...ter the setup menu you can do so via the BIOS setup menu Please refer to section 3 2 for details 1 3 2 Installing an OS Several options are available for OS installation System comes with a preinstalled OS Install an image from a USB key Install an OS via network boot If you use Advantech s services to pre install an OS you can skip the following sec tion 1 3 2 1 Pre Installed reference OS If you ...

Страница 18: ...ert back to the original boot priority After making these changes leave the Setup Menu via Save Exit This will restart the appliance and it will boot from the USB stick 1 3 2 3 Installing an OS via network boot To install an OS via network basically works the same way as booting an OS via USB stick described above The main difference is that instead of a Linux live image you need to install a netw...

Страница 19: ...PXE boot 1 It needs to set BIOS Advanced Network Stack Configuration Network Stack as enabled default setting is disabled 2 When set Network Stack is enabled it may set IPV4 PXE IPV6 PXE function as enabled disabled and set PXE boot wait time range 0 5 Media detect time range 0 50 ...

Страница 20: ...FWA 1320 User Manual 10 3 Save BIOS and reboot system The BIOS will show Checking Media Pres ence if system is not connected PXE server it will show No Media Pres ent ...

Страница 21: ... the related documentation available PXE boot requires a DHCP server and a TFTP server in the network to complete DHCP Server and TFTP server are commonly run on the same machine and collec tively referred to as boot server Setting up such a boot server implies a couple of steps How to guides for setting up Linux as PXE boot server are available on the internet e g https www debian administration ...

Страница 22: ...sentative or Advantech s customer service center for technical support if you need additional assistance Worldwide con tact information can be found on www advantech com 3 Please have the following information ready before you call be sure to include this information in your email Product name and serial number Description of your peripheral attachments Description of firmware and software version...

Страница 23: ...Chapter 2 2 Product Specification ...

Страница 24: ...gher clock frequencies and significantly increased performance gains the new System On Chip processor features tighter I O integration and improved IO bandwidth On chip functions include four server class GbE ports and crypto acceleration for symmetric keys bulk security encryption decryption and public key functions The four Ethernet data ports support optional LAN bypass and are complemented by ...

Страница 25: ... Intel Atom C2000 processor L2 Cache 2 MB 4 MB depending on CPU SKU Memory Technology One DDR3 channel two DDR3 UDIMMs up to 1600 MT s depending on CPU SKU Capacity Up to 16 GB Ethernet LAN on Board 4 x GbE LAN ports integrated in Atom C2000 with 2 segment advanced bypass support optional 2 x GbE management ports Intel I210 AT based no bypass capability Mass Storage SATA 1 x 2 5 SATA HDD or SSD Ot...

Страница 26: ...ety and EMC defined in this chapter Please contact your Advantech representative for a copy of the declaration of conformity or detailed test reports 2 3 2 1 Safety Table 2 4 Applicable Safety Regulations USA Canada UL 60950 1 2nd Edition CSA C22 2 No 60950 1 07 2nd Edition Europe EN 60950 1 2006 A11 2009 A1 2010 A12 2011 International CB Certificate and Report to IEC60950 1 2nd Edition and all in...

Страница 27: ...08 EC EN55022 Class A Limit Radiated Conducted Emissions EN55024 Immunity Characteristics for ITE EN61000 4 2 ESD Immunity EN61000 4 3 Radiated Immunity EN61000 4 4 Electrical Fast Transient EN61000 4 5 Surge EN61000 4 6 Conducted RF EN61000 4 8 Power Frequency Magnetic Fields EN61000 4 11 Voltage Fluctuations and Short Interrupts EN61000 3 2 Harmonic Currents EN61000 3 3 Voltage Flicker Taiwan TB...

Страница 28: ... for signalling important system status at the loca tion of rear side Figure 2 4 Front LEDs 2 4 2 System block diagram Figure 2 5 Block diagram F8 Traffic Port 2 Traffic LAN Port 2 F9 Traffic Port 3 Traffic LAN Port 3 F10 Traffic Port 4 Traffic LAN Port 4 Table 2 6 Front Elements ...

Страница 29: ... C2000 is soldered on the motherboard and cannot be installed later The standard product configurations available including CPU options are listed in section 2 2 If you re interested in the support of other CPU SKUs please contact your Advantech representative For details on the features of the Atom C2000 processor please refer to documenta tion available from intel 2 4 3 Memory Two DDR3L or DDR3 ...

Страница 30: ...the most recent list of validated peripherals or if you would like to use modules not listed Table 2 7 DIMM Mapping Location DIMM Channel Color SMBus Adr D1 1 A Black 0xA0 D2 2 A Amber 0xA2 Table 2 8 Validated DIMMs Vendor Frequency Capacity Advantech PN Apacer DDR3 1333 2G 96D3 2G1333NN AP1 DDR3 1600 96D3 2G1600NN APL DDR3 1333 4G 96D3 4G1333NN AP DDR3 1333 96D3 4G1333E AP DDR3 1600 8G 96D3 8G160...

Страница 31: ...B2 0 port is connected to an onboard header This port is reserved for custom use Please contact your Advantech representative if you are interested to use this port The USB Host Controller is integrated into the Atom C2000 SoC and implements a Enhanced Host Controller Interface compliant to the EHCI 1 0 Specification The EHCI supports up to four USB 2 0 root ports The controller integrates a Rate ...

Страница 32: ...e using memory space The SATA ports are implemented per below table on the FWA 1320 Other SATA ports provided by the Atom C2000 are not used on the FWA 1320 Figure 2 9 mSATA SSD The following list summarizes the drives validated on the FWA 1320 Table 2 11 SATA Ports System SATA Port Implementation Controller Controller Port 1 SATA header 1 location M1 SATA3 Port 0 2 mSATA socket location M3 SATA3 ...

Страница 33: ...GB SATA SSD SQF S25U5 320G S8C Plextor 96FD25 S32 PM 2 5 32GB SATA SSD PX 32G5Me Plextor 96FD25 S256 PM 2 5 256GB SATA SSD PX 256G5Me ADVANTECH SQF S25S8 32G S8C 2 5 32GB SATA SSD SQF S25S8 32G S8C ADVANTECH SQF S25S4 16G S8E 2 5 16GB SATA SSD SQF S25S4 16G S8E ADVANTECH SQF S25S8 512G S8C 2 5 512GB SATA SSD SQF S25S8 512G S8C ADVANTECH SQF S25S8 128G S5C 2 5 128GB SATA SSD SQF S25S8 128G S5C ADVA...

Страница 34: ...nts One timer block is implemented containing one counter and three timers It complies with the IA PC HPET High Precision Event Timers Specification Revision 1 0 available from intel 4 SMBus The PCH integrates two SMBus controllers The first one is used as interface to external devices such as EEPROMs the hardware monitor the second controller is not used on the FWA 1320 Table 2 13 COM Ports UART ...

Страница 35: ... accelerator appears to software as a PCIe endpoint and is used as a look aside coprocessor It supports the features below Symmetric Cryptographic Functions Cipher Operations Hash Authenticate Operation Cipher Hash Combined Operation Key Derivation Operation Public Key Functions RSA Operation Diffie Helman Operation Digital Signature Standard Operation Key Derivation Operation Elliptic Curve Crypt...

Страница 36: ...s probing initialization and configuration of the FWA 1320 and ini tializes the OS boot process at the end of POST Power On Self Test Regular BIOS output as well as the setup menu are displayed via the console port Please refer to section 1 3 3 reg the console connection process The BIOS Setup Menu is described in detail in section 3 2 BIOS Error Codes used during POST are described in appendix B ...

Страница 37: ...tel Atom C2000 RAS 00 0f 00 8086 1f16 IOMMU Intel Atom processor RCEC 00 13 00 8086 1f15 System periph eral Intel Atom C2000 SMBus 2 0 Controller 00 14 00 8086 1f41 Ethernet control ler Intel I354 connected to traffic port labelled 1 00 14 01 8086 1f41 Ethernet control ler Intel I354 connected to traffic port labelled 2 00 14 02 8086 1f41 Ethernet control ler Intel I354 connected to traffic port l...

Страница 38: ...WA 1320 Moreover the following temperatures are supervised The HWM also monitors the front and rear fans In addition to the HWM the ATOM C2000 CPU features integrated temperature sen sors 1 per core that are supported by the coretemp module of lmsensors Figure 2 11 Display of CPU temperature Pin No Pin Name Function 6 VSEN6 Monitor VNN 1V Core Power 7 VSEN7 Monitor V1P0 1V Core Power 8 VSEN8 Monit...

Страница 39: ...tomization Please contact your Advantech representative should you be inter ested in this option 2 5 2 Watchdog The FWA 1320 provides a programmable watchdog that may be used to reset the system in case it bites due to malfunctioning application software to restore the unit to a known good state The watchdog is based on intel s TCO timer and is integrated in the Atom C2000 device The TCO watchdog ...

Страница 40: ...tate such as loss of power or in case the application is unre sponsive Application health is monitored by a configurable watchdog Disconnect mode is typically used to block any traffic until the system has fully started up and the application SW is in a well defined state allowing to handle traffic properly Connectivity can be auto controlled by a number of system events Power Up Host system is tu...

Страница 41: ... show the state of a bypass seg ment Usually the bypass LED is implemented as a dual colour LED combined with a regular LAN port LED The table below shows the status of the bypass LED only For a complete description of port LEDs please refer to appendix A 3 2 2 6 Available Accessories and Related Products 2 6 1 Accessories The following accessories are available for ordering Please contact your Ad...

Страница 42: ...FWA 1320 User Manual 32 ...

Страница 43: ...Chapter 3 3 Configuration and Service ...

Страница 44: ...ers Please contact your Advantech representative if you want to receive more information regarding this service The BIOS Setup Menu can be entered via the BIOS POST screen displayed on the console interface Figure 3 1 BIOS POST screen BIOS Setup can be entered by hitting DEL or F2 keys during POST The BIOS setup menu screens have a few main elements as shown below The menu bar displays the selecta...

Страница 45: ...on entering the BIOS Setup After a successful check or if password protection has not been enabled users will see the Main Setup screen shown below Users can always return to the Main setup screen by selecting the Main tab Figure 3 3 BIOS Setup Main screen The main setup page displays system a summary of system and BIOS configuration and status information The fields on this page are read only exc...

Страница 46: ...highlighting it using the Arrow keys The Advanced BIOS Setup screen is shown below The sub menus are described on the following pages Table 3 1 BIOS Setup Main Menu Group Setup item Access Options Description BIOS Infor mation BIOS Vendor Display only American Megatrends Core Version Display only Current AMI BIOS core version in use Compliancy Display only UEFI Spec revision that the BIOS com plie...

Страница 47: ...Note that the serial console is always using COM1 which is connected to the front panel Figure 3 5 Advanced Setup Console Redirection Menu 3 2 2 2 COM1 Console Redirection Settings The settings for COM1 console can be accessed in this menu is sub menu allows you to change the settings used for the serial console For exam ple users can define the terminal type bits per second data bits parity stop ...

Страница 48: ...es number of data bits in a character Parity None Even Odd Mark Space Defines the parity scheme used Stop Bits 1 2 Defines number of stop bits in a character Flow Control None Xon Xoff Defines the flow control scheme VT UF8 Combo Key Disabled Enabled Enables VT UTF8 Combination Key Support for ANSI VT100 terminals Recorder Mode Disabled Enabled When Enabled the data displayed on a terminal will be...

Страница 49: ...s still apply to the platform as PCIe is using the same configuration mecha nism as PCI Figure 3 7 Advanced Setup PCI Subsystem Redirection after BIOS Always Enable BootLoader This defines how long console redirection will be active BootLoader means that legacy console redirection is disabled before booting into a Legacy OS Always Enable means Legacy console Redirection is enabled permanently Tabl...

Страница 50: ...ed into PCI Latency Timer Register of PCI devices Determines how long slow devices may occupy the PCI bus PCI X Latency Timer 32 64 96 128 160 192 224 248 Value to be programmed into PCI Latency Timer Register of PCI X capa ble devices VGA Palette Snoop Enabled Dis abled Enables snooping of VGA compatible accesses PERR Genera tion Enabled Dis abled Enables or Disables PCI Devices to Generate PERR ...

Страница 51: ...etwork Stack Configuration Menu Group Setup item Access Options Description none Network Stack Enabled Disabled Enables or disables the UEFI Network Stack IPv4 PXE Sup port Enabled Disabled Enables or disables IPv4 support for PXE IPv6 PXE Sup port Enabled Disabled Enables or disables IPv4 support for PXE PXE Boot Wait Time 0 5 Timeout in seconds used by BIOS wait for the ESC key to abort the PXE ...

Страница 52: ... use the display mode set by the sys tem BIOS INT19 Trap Response Immediate Postponed Interrupt 19 is the software interrupt that handles the boot disk function If set to Immediate the Option ROM will immediately capture Interrupt 1 If this item is set to Postponed the option ROM will only capture Interrupt 19 dur ing boot from a legacy device Boot option filter UEFI and Legacy Legacy Only UEFI On...

Страница 53: ...tion Figure 3 10 Advanced Setup Security Menu Table 3 6 Trusted Computing Menu Group Setup item Access Options Description Configuration Security Device Sup Enabled Disabled Enables or disables the support for the TPM Current Sta tus informa tion Support Turned Off Display Only Is displayed when TPM support is dis abled TPM State Display Only Shows TPM Enablement Status TPM Active State Display On...

Страница 54: ...HCI control ler will not be initialized by the BIOS Legacy USB Sup port Auto Enabled Disabled Enables legacy support over USB to support Keyboard and Mouse EHCI Hand Off Enabled Disabled Controls the hand off of EHCI ownership from BIOS to OS at boot time Mass Storage Driver Enabled Disabled Enables support for USB mass storage devices in the BIOS like a USB DOM or a USB stick This option needs to...

Страница 55: ...kept consistent with previous products to allow users to navigate more eas ily The sub menus are described on the following pages Figure 3 12 Chipset Configuration Menu Mass Stor age Devices This section displays the Mass Storage Devices detected by the BIOS if any It also allows to define how these devices will be presented ID of Device 1 Auto Floppy Forced FDD Hard Disk CD ROM Shows the ID of th...

Страница 56: ... ATOM C2000 CPU Figure 3 13 Chipset Processor Configuration Menu Table 3 8 Processor Configuration Menu Group Setup item Access Options Description Processor Configuration Processor ID Display only Displays information on the processor installed Processor Fre quency L1 Cache RAM L2 Cache RAM Processor Ver sion ...

Страница 57: ...able or Disable the Monitor Mwait instruction L1 Prefetcher Disable Enable Enable Disable L1 Prefetcher L2 Prefetcher Disable Enable Enable Disable L2 Prefetcher Machine Check Disable Enable Execute Disable Bit Disable Enable Execute Disable Bit is a mechanism which allows OSes and software to become less vulnerable to viruses and malware VMX Enable Enables Virtualization Support Virtual Mode Exte...

Страница 58: ...This menus supports configuration of the platform clock generator Figure 3 14 CK420 Configuration Menu Table 3 9 CK420 Configuration Menu Group Setup item Access Options Description CK420 Spread Spectrum Enabled Disabled Enables Spread Spectrum Operation for lower EMI ...

Страница 59: ...al Chapter 3 Configuration and Service 3 2 3 3 Chipset Setup North Bridge Configuration This menu allows the configuration of the memory controller and related features of the SoC Figure 3 15 NorthBridge Configuration Menu ...

Страница 60: ...speed is under 1600 ECC Support Enabled Disabled Selected to enable disable ECC Sup port Faulty Part Track ing Enabled Disabled Select to enabled disable faulty part tracking which allows identification and isolation of defective DRAM chips On Correctable Faulty Part Halt Continue On correctable faults halt or continue Patrol Scrub Enable Enabled Select to enable disable Patrol Scrub Support For m...

Страница 61: ...t Setup South Bridge Configuration Figure 3 16 South Bridge Configuration South Bridge Configuration SATA Configuration Figure 3 17 SATA Configuration Table 3 11 South Bridge Configuration Feature Default Description SMBus Controller Enabled Enabled Disabled SMBus Controller ...

Страница 62: ...ort2 Display only SATA Port3 Display only SATA Port4 Display only SATA Port5 Display only SATA Mode AHCI Mode 1 IDE Mode 2 AHCI Mode 3 RAID Mode Aggressive Link Power Enabled Aggressive Link Power Management Support For Cougar Point B0 stepping onwards Note If ONLY the Administrator s password is set then this only limits access to Setup and is only asked for when entering Setup If ONLY the User s...

Страница 63: ...ication Figure 3 19 Boot Configuration Table 3 13 Boot Configuration Feature Default Description Setup Prompt Timeout 1 Number of seconds to wait for setup activation key Bootup NumLock State On Select the keyboard NumLock state Quiet Boot Disabled Enables or disables Quiet Boot option Fast Boot Disabled Enables or disables boot with an initialization of a minimal set of devices required to launch...

Страница 64: ...t Reset system after saving the changes Does not update User Defaults Discard Changes and Reset Reset system without saving the changes Save Options Save Changes Save Changes made so far to any of the setup options Discard Changes Discard Changes made so far to any of the setup options Restore Defaults Restores the BIOS factory defaultsto all the setup options Save as User Defaults Saves the Curre...

Страница 65: ... the HDD s mount ing threads with 2 holes on each side of the carrier plate The holes to use may vary from disk vendor to disk vendor For some vendors all 4 holes may align 3 Insert the screws supplied as part of the HDD kit into the holes and HDD threads Make a few turns on each screw only using a PH2 screw driver until the threads start to engage Then move on to the next screw When all four scre...

Страница 66: ...be installed at location M6 Figure 3 23 USB DOM site with header standoff 1 Make sure the USB DOM is compliant with the socket 2 Insert the DOM onto the header from the top Make sure the header and recep tacle align properly as shown below Figure 3 24 USB DOM alignment 3 If properly inserted The mount hole in the DOM and the threaded insert will be aligned Insert the DOM mounting screw and tighten...

Страница 67: ... the unit Figure 3 26 mSATA mounting screw An mSATA compliant SSD can be installed at location M3 1 Make sure the mSATA disk is compliant with the socket and that the mechanical keys match Figure 3 27 mSATA key alignment 2 Insert the mSATA module in the connector under an angle of around 45 The gold contacts of the module will almost disappear in the connector when the module is fully seated ...

Страница 68: ...tandoff in the FWA 1320 motherboard Insert the mSATA mounting screw and tighten it Figure 3 29 mSATA mounting 3 3 2 Memory Installation After removing the top cover follow the instructions below for DIMM installation 1 Double check that the DIMMs to be installed match the requirements of section 2 4 5 2 Open the white latches on the left and right sides of the DIMMs by turning it out wards as indi...

Страница 69: ...and Service Figure 3 30 Opening DIMM latches 3 Select DIMM orientation so that the keys in the DIMM module and socket match Figure 3 31 DIMM key alignment 4 Insert the DIMM from the top using the guide rails on the left and right of the DIMM sockets ...

Страница 70: ... rails 5 Put your thumbs near the right and left end of the DIMM and press down the DIMM evenly until the white latches fully close with a click Figure 3 33 Seating the DIMM in the socket 6 In case you want to install another DIMM repeat steps 1 to 5 accordingly ...

Страница 71: ...r to the Advanced LAN Bypass User s Manual for details 3 5 Replacing FRUs Please make sure you follow the safety guidelines presented in section1 1 when making changes to the hardware For instruction on how to remove and install the top cover of the unit please refer to section 3 3 3 5 1 Disk drives 3 5 1 1 2 5 HDD You need a PH2 screw driver A standard 2 5 SATA HDDTo remove the HDD proceed in the...

Страница 72: ...dule upwards once the screw is lose 2 Extract the mSATA module Install a new SSD following the mounting instructions of the same section 3 5 2 CMOS Battery You need A BR2032 battery To replace the RTC s battery located at B1 pull the spring clip securing the battery forward with your finger tip Please handle with care and do not bend the spring clip Then extract the battery vertically Figure 3 34 ...

Страница 73: ... and control that it moves back into its original position and that it secures the battery correctly 3 5 3 DIMMs To replace a DIMM module basically extract the DIMM module by pushing the DIMM socket latches outward As the latches flip completely open the DIMM module will be automatically extracted from the socket Pull the DIMM module out vertically Figure 3 36 Unlocking and removing a DIMM To inse...

Страница 74: ...FWA 1320 User Manual 64 ...

Страница 75: ...Appendix A A Connector Pinout and LED Information ...

Страница 76: ...A connector Table A 1 Console Connector Pin Assignment Pin No Signal Name Description 1 n c Not connected 2 n c Not connected 3 TX Transmit Data Output from FWA 1320 4 GND Digital Circuit Ground 5 GND Digital Circuit Ground 6 RX Receive Data input to FWA 1320 7 n c Not connected 8 n c Not connected Table A 2 Stacked USB Type A Connector Pin Assignment Pin No Signal Name Description 1 VCC_USB0 USB ...

Страница 77: ...Dependent Interface 0 2 MDI 0 Media Dependent Interface 0 3 MDI 1 Media Dependent Interface 1 4 MDI 2 Media Dependent Interface 2 5 MDI 2 Media Dependent Interface 2 6 MDI 1 Media Dependent Interface 1 7 MDI 3 Media Dependent Interface 3 8 MDI 3 Media Dependent Interface 3 Table A 4 RJ45 Connector LED Indication Speed LED Left Green Amber Color Link Active LED Right Green Amber Color 10 Mbps Off L...

Страница 78: ...FWA 1320 User Manual 68 ...

Страница 79: ...Appendix B B BIOS Post Codes ...

Страница 80: ...ry North Bridge initialization is started 0x16 Pre Memory North Bridge initialization North Bridge module specific 0x17 Pre Memory North Bridge initialization North Bridge module specific 0x18 Pre Memory North Bridge initialization North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre memory South Bridge initialization South Bridge module specific 0x1B Pre me...

Страница 81: ...de update is failed 0x5A Internal CPU error 0x5B reset PPI is not available 0x60 DXE Core is started 0x61 NVRAM initialization 0x62 Installation of the South Bridge Runtime Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU mod...

Страница 82: ...is started 0xA1 IDE Reset 0xA2 IDE Detect 0xA3 IDE Enable 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL 0xAB Setup Input Wait 0xAC Reserved for ASL 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Vi...

Страница 83: ...LoadImage returned error 0xDA Boot Option is failed StartImage returned error 0xDB Flash update is failed 0xDC Reset protocol is not available 0XE0 S3 Resume is stared S3 Resume PPI is called by the DXE IPL 0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found 0xEA S3 Resume Boot Script Error 0xEB S3 OS Wake Error 0xF0 0xF4 u...

Страница 84: ...FWA 1320 User Manual 74 ...

Страница 85: ...Appendix C C Declaration of Conformity ...

Страница 86: ... been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manu...

Страница 87: ...Appendix D D Warranty and RMA ...

Страница 88: ...he cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered for example Advan tech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your deale...

Страница 89: ...79 FWA 1320 User Manual Appendix D Warranty and RMA ...

Страница 90: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2015 ...

Отзывы: