EKI-9628G User Manual
113
4.12.6
Reset System
To access this page, click
Tools
>
Reset System
.
Click
Reset
to have all configuration parameters reset to their factory default values.
Click
except for
to select the configuration are excepted. All changes that have been
made will be lost, even if you have issued a save.
Reset settings take effect after a system reboot.
4.12.7
Reboot Device
To access this page, click
Tools
>
Reboot Device
.
Click
Reboot
to reboot the switch. Any configuration changes you have made since
the last time you issued a save will be lost.
4.13
Modbus/TCP Mapping
The data map addresses of Advantech switches shown in the following table start
from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.13.1
Modbus/TCP Mapping Table
Catelog
Name
Data Type
Interpretation
Address Offset
(Hex)
Address
3X
Description
System Info Vendor ID =
0x‘13FE
1 word
16 bits
HEX
0x0000
30001
Vendor ID = 0x13FE
Unit ID =
0xFF
1 word
16 bits
HEX
0x0001
30002
Unit ID = 0xFF
Product Code 1 word
16 bits
HEX
0x0002
30003
Product Code
Vendor Name
= "Advan-
tech"
16 words 32 chars ASCII
0x0010
30017
Vendor Name =
"Advantech"
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'd'
Word 1 Hi byte = 'v'
Word 1 Lo byte = 'a'
Word 2 Hi byte = 'n'
Word 2 Lo byte = 't'
Word 3 Hi byte = 'e'
Word 3 Lo byte = 'c'
Word 4 Hi byte = 'h'
Word 4 Lo byte = '\0'
Содержание EKI-9628G
Страница 1: ...User Manual EKI 9628G 24G 4G Combo port L3 Managed Switch...
Страница 14: ...Chapter 1 1Product Overview...
Страница 19: ...Chapter 2 2Switch Installation...
Страница 33: ...Chapter 3 3Configuration Utility...
Страница 39: ...Chapter 4 4Managing Switch...
Страница 144: ...EKI 9628G User Manual 131...
Страница 145: ...132 EKI 9628G User Manual...
Страница 146: ...Chapter 5 5Troubleshooting...