EKI-7720 Series User Manual
21
5.
Tighten the wire-clamp screws to secure the DC wires in place.
Figure 2.21 Installing DC Wires in a Terminal Block
6.
Align the terminal block over the terminal block receptor on the switch.
7.
Insert the terminal block and press it in until it is flush with the terminal block
receptor.
8.
Tighten the screws on the terminal block to secure it to the terminal block recep
-
tor.
If there is no gap between the terminal block and the terminal receptor, the ter
-
minal block is seated correctly.
Figure 2.22 Securing a Terminal Block to a Receptor
2.8
Reset Button
Reset configuration to factory default:
Press and hold Reset button for 5 seconds.
System reboot:
Press and hold Reset button for 2 seconds.
1A@24V
1A@24V
Loosening
Wire-clamp
Screws
Installing DC
Wires
Securing
Wire-
clamp Screws
1A@24V
Note!
Do NOT power off the Ethernet switch when loading default settings.