10
EKI-7720 Series User Manual
2.3.1.2
Removing the DIN-Rail Mounting Kit
1.
Ensure that power is removed from the switch, and disconnect all cables and
connectors from the front panel of the switch.
2.
Push down on the top of the DIN rail clip release tab with your finger. As the clip
releases, lift the bottom of the switch, as shown in the following illustration.
\
Figure 2.3 Removing the DIN-Rail
2.3.2
Wall-Mounting
The wall mounting option provides better shock and vibration resistance than the DIN
rail vertical mount.
Before the device can be mounted on a wall, you will need to remove the DIN rail
plate.
1.
Rotate the device to the rear side and locate the DIN mounting plate.
2.
Remove the screws securing the DIN mounting plate to the rear panel of the
switch.
3.
Remove the DIN mounting plate. Store the DIN mounting plate and provided
screws for later use.
4.
Align the wall mounting plates on the rear side. The screw holes on the device
and the mounting plates must be aligned, see the following illustration.
Note!
When installing, make sure to allow for enough space to properly install
the cabling.