EKI-7720 Series User Manual
131
To access this page, click
Management
>
RMON
>
RMON Event
.
Figure 4.208 Management > RMON > RMON Event
The following table describes the items in the previous figure.
The ensuing table for
Event Information
settings are informational only: Index,
Description, Type, Community, Owner and
Delete
(click to delete the desired index).
Item
Description
Index
Enter the index entry (1 to 65535) to define a specific RMON event.
Description
Enter a value (1 to 2147483647) to define the interval value for the
Alarm Collection history.
Type
Click the drop-down menu to define the event type: None, Log, SNMP
Trap, Log and Trap.
Community
Enter the community string to be passed for the specified event.
Owner
Enter the name of the owner of the RMON event.
Apply
Click
Apply
to save the values and update the screen.