129
EKI-7716 Series User Manual
The following table describes the items in the previous figure.
Item
Description
IPv6 Address
Enter the IP address or host name of the station you want the switch
to ping. The initial value is blank. The IP Address or host name you
enter is not retained across a power cycle. Host names are composed
of series of labels concatenated with dots. Each label must be
between 1 and 63 characters long, and the entire hostname has a
maximum of 64 characters.
Count
Enter the number of echo requests you want to send. The default
value is 4. The value ranges from 1 to 5. The count you enter is not
retained across a power cycle.
Interval (in sec)
Enter the interval between ping packets in seconds. The default value
is 1. The value ranges from 1 to 5. The interval you enter is not
retained across a power cycle.
Size (in bytes)
Enter the size of ping packet. The default value is 56. The value
ranges from 8 to 5120. The size you enter is not retained across a
power cycle.
Ping Results
Display the reply format of ping.
PING 2222::777 (2222::777): 56 data bytes
--- 2222::777 ping statistics ---
4 packets transmitted, 0 packets received, 100% packet loss
Or
PING 2222::717 (2222::717): 56 data bytes
64 bytes from 2222::717: icmp6_seq=0 ttl=128 time=10.0 ms
64 bytes from 2222::717: icmp6_seq=1 ttl=128 time=0.0 ms
64 bytes from 2222::717: icmp6_seq=2 ttl=128 time=0.0 ms
64 bytes from 2222::717: icmp6_seq=3 ttl=128 time=0.0 ms
--- 2222::717 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.0/2.5/10.0 ms
Apply
Click
Apply
to display ping result for the IP address.
Содержание EKI-7716 Series
Страница 1: ...User Manual EKI 7716 Series 8GE 4SFP 4G Combo port Managed Redundant Industrial Switch ...
Страница 14: ...Chapter 1 1Product Overview ...
Страница 20: ...Chapter 2 2Switch Installation ...
Страница 35: ...Chapter 3 3Configuration Utility ...
Страница 41: ...Chapter 4 4Managing Switch ...
Страница 152: ...Chapter 5 5Troubleshooting ...