79
EKI-7716 Series User Manual
The ensuing table for
DoS Global Information
settings are informational only:
DMAC = SMAC, Land Attack, UDP Blat, TCP Blat, POD (Ping of Death), IPv6 Min
Fragment Size, ICMP Fragment Packets, IPv4 Ping Max Packet Size, IPv6 Ping Max
Packet Size, Smurf Attack, TCP Min Header Length, TCP Syn (SPORT < 1024), Null
Scan Attack, X-Mas Scan Attack, TCP SYN-FIN Attack, TCP SYN-RST Attack and
TCP Fragment (Offset = 1).
UDP Blat
Click
Enabled
or
Disabled
to define UDP Blat for the DoS Global set-
tings.
TCP Blat
Click
Enabled
or
Disabled
to define TCP Blat for the DoS Global set-
tings.
POD
Click
Enabled
or
Disabled
to define POD for the DoS Global settings.
IPv6 Min Fragment
Click
Enabled
or
Disabled
to define minimum fragment size for the
IPv6 protocol.
Enter the variable in bytes (0 to 65535) to set the minimum fragment
size when the function is enabled.
ICMP Fragments
Click
Enabled
or
Disabled
to define the ICMP Fragments function.
IPv4 Ping Max Size
Click
Enabled
or
Disabled
to set the maximum ping size for the IPv4
protocol.
IPv6 Ping Max Size
Click
Enabled
or
Disabled
to set a maximum ping size for the IPv6
protocol.
Ping Max Size Set-
ting
Enter the variable in bytes (0 to 65535) to set the maximum ping size.
Smurf Attack
Click
Enabled
or
Disabled
to set the Smurf Attack function.
TCP Min Hdr Size
Click
Enabled
or
Disabled
to set the minimum header size.
Enter the variable in bytes (0 to 31) to set the minimum header size.
TCP-SYN (SPORT <
1024)
Click
Enabled
or
Disabled
to set the TCP synchronization function
(sport < 1021).
Null Scan Attack
Click
Enabled
or
Disabled
to set the Null Scan Attack function.
X-Mas Scan Attack
Click
Enabled
or
Disabled
to set the X-Mas Scan function.
TCP SYN-FIN Attack Click
Enabled
or
Disabled
to set the TCP synchronization termina-
tion attack function.
TCP SYN-RST
Attack
Click
Enabled
or
Disabled
to set the TCP synchronization reset
attack function.
TCP Fragment (Off-
set = 1)
Click
Enabled
or
Disabled
to set the TCP fragment function (offset
=1).
Apply
Click
Apply
to save the values and update the screen.
Item
Description
Содержание EKI-7716 Series
Страница 1: ...User Manual EKI 7716 Series 8GE 4SFP 4G Combo port Managed Redundant Industrial Switch ...
Страница 14: ...Chapter 1 1Product Overview ...
Страница 20: ...Chapter 2 2Switch Installation ...
Страница 35: ...Chapter 3 3Configuration Utility ...
Страница 41: ...Chapter 4 4Managing Switch ...
Страница 152: ...Chapter 5 5Troubleshooting ...