16
EKI-6233BN User Manual
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup
the best possible noise immunity and emissions.
Figure 2.14 Grounding Connection
By connecting the ground terminal by drain wire to earth ground the gateway and
chassis can be ground.
2.2.5.4
Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the
EKI-6233BN is wired and then installed onto the terminal receptor located on the
EKI-6233BN.
Figure 2.15 Terminal Receptor: Relay Contact
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and
two for a fault circuit.
2.2.5.5
Wiring the Power Inputs
Note!
Before applying power to the grounded gateway, it is advisable to use a
volt meter to ensure there is no voltage difference between the power
supply’s negative output terminal and the grounding point on the
gateway.
Drain Wire with Lug
Connection to
Grounding Point
P-Fail
V2- V2+
V1- V1+
PWR2
PWR1
Caution!
Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the device.
Warning!
Power down and disconnect the power cord before servicing or wiring
the gateway.
Содержание EKI-6233BN
Страница 1: ...User Manual EKI 6233BN Industrial Wi Fi Client ...
Страница 2: ...EKI 6233BN User Manual ii ...
Страница 12: ...Chapter 1 1Introduction ...
Страница 16: ...Chapter 2 2Getting Started ...
Страница 30: ...Chapter 3 3Utility Configuration ...
Страница 44: ...Chapter 4 4Web Interface ...
Страница 69: ...Chapter 5 5Telnet Configuration ...