![background image](http://html1.mh-extra.com/html/advantech/arma-c250-crm/arma-c250-crm_installation-and-operating-manual_2858252023.webp)
ARMA-C250-CRM
22
TABLE 11
: STATUS INDICATORS
Function
Description of ON condition
Display
Power On
AC power supplied
LED, Green
RF On
RF output signal detected
LED, Green
Remote
Remote amplifier control is enabled --
Front panel control of some functions is disabled.
LED, Green
Mute
RF output disabled by operator
LED, Amber
Alarm
Thermal, Low output or incorrect WG position
detected
LED, Amber
Fault
Fault condition detected
LED, Red
TABLE 12
: REDUNDANT INDICATORS
Function
Description of ON condition
Display
Auto
For redundant only (Automatic Switching is enabled)
LED, Green
On-Line
For redundant only (Amplifier connected to antenna)
LED, Green
Stand-by
For redundant only (Amplifier terminated to load)
LED, Amber
Figure 5