ARMA-C250-CRM
32
12.
‘1’ - A request to go LOCAL was issued / ‘0’- no event
13.
‘1’ - Computer interface in control / ‘0’- Hardware interface in control (if byte #9 is a ‘1’)
F3 - Requests alarm or fault message. No message bytes are shown if no message is available.
See ‘F2’ response byte 11.
F4 - Requests various parameters. After disregarding the header, ‘P’ indicates this is a parameter
response;
‘A’ is followed by an attenuation level (20.0 dB on power-up)
‘C’ is followed by supply current
‘M’ is followed by user threshold in dBm
‘O’ is followed by output power in dBm
‘R’ is followed by reflected power in dBm
‘TM’ is followed by power module’s hot spot temperature in Celsius
‘TS’ is followed by shroud temperature in Celsius
F5 - Resets faults and restarts the unit for all alarm conditions except over temperature (which
restarts by itself when the unit cools down).
F6 - MUTE the unit.
F7 - Brings the amplifier back to its pre-MUTE state.
F8 - Sets the attenuator level. For 0 dB level enter 0, for 15 dB enter 150, for 20 dB enter 200.
(0.1 dB steps, no decimal required).
F9 - Selects the unit. Any value between 0 and 15. (Default: 0)
F10 - ‘MORE’ goes to next menu (screen) page.
Содержание ARMA-C250-CRM
Страница 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Страница 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Страница 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Страница 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Страница 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...