V. Start-Up

  A.    Priming the pump

   

Plug in pump.  While pump is operating, watch suction line. If fluid begins moving, no further priming 

 

      is required. If fluid is not moving, open bleed valve until fluid begins to move. When suction line 

 

      fills,  close  bleed  valve. 

Do not over tighten bleed valve, damage may occur. 

Thumb  and   

      forefinger are all that are required to tighten valve. Further tightening will cause damage to bleed  

 

      valve which will result in flow loss.

 

B.    Output Information

 

Pump  

Strokes per  Gallons Per Day 

Liters Per Hour 

Milliliter Per Stroke

 

Model  

 Minute 

Min           Max 

Min            Max   

Min            Max

 

C-105

 

20 

0.16  

0.8 

0.125 

0.63

 

C-110

  45 

2  10  0.31  1.6 0.125  0.63

 

C-115

 

65 

3  15  0.47  2.37 0.125  0.63

 

C-120

 

85 

4  20  0.63  3.15 0.125  0.63

 

C-130

  125 

6  30  0.94  4.7 0.125  0.63

 

C-202

 

15 

0.5 

0.06  

0.31 

0.07 

0.35

 

C-205

  35 

1  5  0.16  0.8 0.07  0.35

 

C-210

  75 

2  10  0.31  1.6 0.07  0.35

 

C-215

  110 

3  15  0.47  2.4 0.07  0.35

 

C-217

  125 

3.5  17  0.54  2.6 0.07  0.35

 

C.   Adjusting Stroke Length

 

The stroke length can be adjusted on most MicroTron™ pumps.  This adjustment is a mechanical  

  adjustment made using the large knob on the control panel.  To avoid damage to the pump, this  

  adjustment  should only be made while the pump is running at a high stroking rate.

  D.     Optional Features

  

1.  External Pacing

 

 

The external pacing option allows the speed of the pump to be controlled by an external device  

   

like a flow meter that gives dry contact switch closures.  The pump sends out a 5 volt D.C. current 

 

   

to  read a switch closure.  Each time the pump sees the switch closure it strokes once, up to it’s  

   

maximum strokes per minute rate.

          

   2.  Hall Effect Meter Pacing

   

This option is like the external pacing only the pump divides the incoming switch closures by 9  

   

before stroking on time.  This is a three wire connection: D.C. voltage, signal and ground.

            

3.  External Stop

  

Pumps with this option are allowed to stroke as long as they see a closed condition from a  

   

dry contact source like a flow switch or drum level wand.  When an open condition is seen the 

 

   

pump is not allowed to stroke.

            

4.  No Stroke Length Adjustment

   

Pumps with this option have no stroke length adjustment and  no turn down capability.  Their  

   

output is fixed at the maximum. 

 

Содержание MicroTron C Series

Страница 1: ...age Controls P O Box 1472 Muskogee OK 74402 Phone 800 743 7431 Fax 888 686 6212 www advantagecontrols com FJ 30 05 2018 MicroTron Series C Chemical Metering Pump Installation Maintenance Repair Manual Manual ...

Страница 2: ...onally or otherwise or any unauthorized repair Advantage is not responsible for damages injuries or expense incurred through the use of its products The above warranty is in lieu of other warranties either expressed or implied No agent of ours is authorized to provide any warranty other than the above 30 Day Billing Memo Policy Advantage Controls maintains a unique factory exchange program to ensu...

Страница 3: ...less Seat Material V Viton standard F Teflon H Hypalon Check Ball C Ceramic standard D Ceramic single on discharge pressure relief S Stainless Tubing Connections 1 3 8 PE 75 200 psi standard 2 PE 250 psi models standard P MNPT V 3 8 Clear flexible suction tubing Special Options C Dust Cover E External stop S 3 function injection valve R No stroke length adjustment knob NOTES This list represents o...

Страница 4: ...nd aprons are critical in preventing accidental exposure to dangerous chemicals Liquids under pressure can present a special hazard when a line or seal is punctured resulting in the spraying of chemical many yards away If a chemical spill occurs consult the Material Safety Data Sheet MSDS for specific instructions regarding the chemical being used IV Installation A Location Select a mounting locat...

Страница 5: ...S 1 Clear flexible tubing is not intended for pressurized use 2 When cutting lengths of tubing for your installation ensure a clean square cut Use short lengths of tubing and as few connections as possible 3 There is an approximate 2 5 psi capability lost for ever 1 foot of vertical rise of the discharge tubing to the injection point Tubing Connections 2 Suction Lift vs Flooded Suction Application...

Страница 6: ...r NOTE When installation is made into a line with zero pressure or when pumping into an open vessel use our optional three function valve for positive back pressure and anti syphon injection valve 6 Optional Three Function Valve The optional 3 function valve injection assembly provides three functions in one injection valve assembly Anti siphon feature allows metering of liquids down hill or into ...

Страница 7: ...ed on most MicroTron pumps This adjustment is a mechanical adjustment made using the large knob on the control panel To avoid damage to the pump this adjustment should only be made while the pump is running at a high stroking rate D Optional Features 1 External Pacing The external pacing option allows the speed of the pump to be controlled by an external device like a flow meter that gives dry con...

Страница 8: ...nterclockwise direction Be careful that the diaphragm support ring does not fall out See liquid end diagram on page 9 4 Replace shaft seal if necessary 5 Screw new diaphragm onto pump shaft until it bottoms out on shoulder of shaft It is not necessary to tighten further 6 Replace fluid end Make sure that screws are evenly tightened 7 Replace fluid end cover 8 Reconnect plumbing and power Prime the...

Страница 9: ...Complete Head Kit 2 Injection Valve 3 Foot Valve 4 Suction Valve 5 Discharge Valve 6 Bleed Valve Assembly 7 Pump Head 8 Pump Diaphragm 9 Support Ring 10 Shaft Seal 11 Head Bolts 12 Priming Tube 13 Suction Tubing 14 Discharge Tubing 15 Weight Complete Head Kit includes items 4 5 6 7 8 and 11 ...

Страница 10: ...onal 3 Function Injection Valve 3FV __ __ __ __ 3 Foot Valve Assembly FTV __ __ __ __ 4 Suction Valve Assembly SUC __ __ __ __ 5 Discharge Valve Assembly DIS __ __ __ __ 6 Priming Valve Assembly PRI __ __ __ __ Body Seat Ball Connection K Kynar V Viton C Ceramic 1 3 8 Tube S 316 Stainless F Teflon D Single 2 1 4 Tube H Hypalon S Stainless 3 3 8 Tube K 3 8 Tube P 1 4 Pipe U 3 8 UV V 3 8 Clear Sucti...

Страница 11: ...e too high Inject into a lower pressure point in the the system Diaphragm worn or torn Replace diaphragm Excessive fluid Failure or lack of anti siphon valve Inspect or add anti siphon valve This is caused when system is in a vacuum condition or a flooded suction application on systems at very low pressures Improper stroke length Reduce stroke length Pump will not pump System pressure too high Che...

Страница 12: ... of your water treatment equipment needs Cooling Tower Controllers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Liquid Level Controllers Glycol Feed Systems Pre Fabricated Systems Get the Advantage ...

Отзывы: