4.2
Prepare the Gap Set Fixture
4.2.1
Check the Zeroing Plate
Make sure the zeroing plate is in place and both
screws are secured tight.
4.2.2
Zero the MIcrometer
With the zeroing plate tightly secured, remove the
tip protector.
The large dial should read 0.000
The small dial should read 0.300
If large hand does not read zero:
Loosen the bezel lock.
Rotate the outside bezel until the large hand
needle is aligned with zero.
Tighten the bezel lock.
Replace the tip protector.
4.2.3
Remove the
Zeroing Plate
Loosen the two
thumbscrews securing
the zeroing plate.
4.2.4
Attach the Jet
With the mounting plate facing up, use the nozzle plate screws to secure the
jet body to the fixture.