2.3
Remove Mounting Plates and Top Cover
KEEP
these parts and screws to set aside and reinstall. A checklist is provided in
section 2.7.
If a heated feed tube enclosure is installed, loosen the thumbscrew to remove the lower feed tube
enclosure. Use the 2.5 mm driver to remove and set aside the two screws securing the upper feed tube
enclosure.
If a syringe is still in place, remove the feed tube from the nozzle plate fluid barb, loosen the syringe
holder thumbscrew, and remove the fluid syringe.
Using the 3 mm driver, remove and set aside:
The four screws securing the dovetail plate
The two screws securing the mounting plate
The two screws securing the syringe holder
The two screws securing the top cover
The two nozzle plate screws
KEEP
KEEP
KEEP
Page 12 of 30
Advanjet HV-2100 Jet Maintenance and Repair
3A6326A