Zonal LED Indicators 

The operation and functions described in this manual are available from Software Version 4000-016-00 onwards. 

 

 

The zonal LED indicator cards are a range of panel mounted peripheral modules that can be added to the 
MxPro 4 series of control panels. The cards are available in numerous configurations and provide individual 
indication of the zone(s) in fire.  The units fully support the MxPro 4 systems DynamiX zoning facilities on 
networked or larger stand-alone systems and can be used to provide individual zonal LED indication at one 
location. 

The Mxp-024F and Mxp-025F are 20 zone units, which are fitted to the front display plate on an MxPro 4 
series control panel.  The Mxp-013-050F, Mxp-013-100F and Mxp-200F incorporate 50, 100 or 200 LED 
indicators respectively and are compatible with all of the MxPro 4 series multi-loop panels. The zone range on 

the 100 way card can be assigned using an on board DIL switch and multiple cards can be placed in banks to 
allow indication of up to 1000 zones using standard units.  

The cards are capable of simultaneously displaying all zones in a fire condition and incorporate a unique 
power saving feature to minimise the power drawn from the control panel in the event of a major fire. Several 
other options are also available within the MxPro 4 range for an application where indication of fire signals 
from zones in addition to the panels’ graphical display is required. These options include Advanced Mimic 
Units, graphics systems and printers. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Insert Image 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание Mx Pro 4

Страница 1: ...el The Mxp 013 050F Mxp 013 100F and Mxp 200F incorporate 50 100 or 200 LED indicators respectively and are compatible with all of the MxPro 4 series multi loop panels The zone range on the 100 way ca...

Страница 2: ...ted from 1 to 1000 E g 1 100 101 200 901 1000 The 20 and 50 zone cards display zones 1 20 and zones 1 50 respectively In the event of more than 50 zones entering a fire condition the LED s will change...

Страница 3: ...LATION 4 1 1 MXP 024F 4 1 2 MXP 025F 4 1 3 MXP 013 XXXF 5 1 3 1 Mxp 013 050 Mxp 013 100 5 1 3 2 Mxp 013 200 5 2 CONFIGURATION 6 3 OPERATION 6 3 1 TESTING THE ZONAL LED INDICATORS 6 www acornfiresecuri...

Страница 4: ...lace with the 4x nuts d Re connect the ribbon cable to the LED card e Test the LED operation refer to Operation Section Mxs 024 Interconnecting Cable Display Card 4x M3 Nut NOTE If a network interface...

Страница 5: ...range refer to Configuration Section f Test the LED operation refer to Operation Section 1 3 2 Mxp 013 200 The Mxp 013 200 consists of 2x 100 LED Indicator cards mounted on the fascia plate and connec...

Страница 6: ...the first 50 zones in each of the ranges 3 Operation When a zone changes state to a fire condition the corresponding zone LED will illuminate The Zone LED Indicators will be turned off when the panel...

Страница 7: ...USER NOTES www acornfiresecurity com www acornfiresecurity com...

Страница 8: ...www acornfiresecurity com www acornfiresecurity com...

Отзывы: