4.3 Starting the pump and adjusting the water flow 

 

DO NOT flood the pads with water, keep them moist. New pads will take a few days before they 
become completely saturated. It is normal to have several dry streaks on the face of the pads 
about 25 to 50 mm wide. If the streaks are larger adjust the flow control knob to allow more water 
to flow onto the pads. NOTE: New pads may also emanate an odour under initial operating 
conditions from the resin used to construct the media. Flush the pads by running the pump 
without the fan running for approximately at least 12 hours; overnight is best. Empty the sump 
and refill. Repeat if odour still exists.

 

 
NOTE: 

Run fan while adjusting the water flow 

Once the sump is full, the pump 

switch may be turned to the ‘ON’ position.

 The flow control 

knob will need to be adjusted on initial start-up. It is located at the side of the unit; it 
controls the volume of water that is delivered to the top of the cooling pads. 
 

 

Prolonged use of hard water without proper water treatment will create mineral deposit 

build up causing the pump to fail which is NOT COVERED BY WARRANTY

 

 

 

Pump is equipped with a 

LOW WATER CUT OFF

 which may take up to 5 minutes to reset each 

time the power is turned on.

 

 

5.0 Maintenance and storage 

 

ELECTRICAL SHOCK HAZARD 

Disconnect the power supply before performing any service or maintenance on the unit. Failure 
to do so may result in serious injury or death.

 

 

5.1 Removing the cooling media to access the inside of the unit 

In order to perform any maintenance on internal components, the cooling pads must be 
removed to access the inside of the unit. 
 

1.  Remove the (2) bolts connecting the pad retainer bar (pad-side) from the housing. 

2.

  Tilt pads from the top, starting with the center pad, out of the unit.

 

Note: Reinstall pads correctly according to the markings on the pads. 

 

5.2 Daily maintenance 

 

When shutting down the COOL-

SPACE

®

 

unit at the end of each workday, the pump should be 

turned off approximately 15 minutes before the fan is turned off. This will allow the pads to drain 
and dry out. This simple guideline will ensure long and efficient pad life as well as help to 
control mildew and bacteria growth. 

Содержание COOL-SPACE CS5-16

Страница 1: ...16 CS6 36 CS5 48 220V 60HZ GLACIER AVALANCHE BLIZZARD IMPORTANT SAFETY INFORMATION INSIDE Serious Injury or death possible Read understand and follow all safety information and instructions in the manual before using or servicing this product ...

Страница 2: ... adjusting the water flow 4 5 0 Maintenance and storage 4 5 1 Removing the cooling media accessing the inside of the unit 4 5 2 Daily maintenance 4 5 3 Periodic maintenance 5 5 4 Storage 5 6 0 Troubleshooting Repair 6 6 1 Troubleshooting 6 9 6 2 Repair procedures 10 11 6 3 Technical support 11 7 0 Warranty 12 7 1 Warranty form 12 7 2 Warranty parts 12 7 3 Optional accessories and replacement parts...

Страница 3: ...ger units are shipped on a wooden skid with a cardboard cover and lid The cardboard cover simply lifts off the COOL SPACE unit The cooler must be lifted off the wooden skid 3 0 Set up of the COOL SPACE unit The COOL SPACE unit is factory tested and ready to use The unit should be placed on a level surface and the castors locked to prevent inadvertent movement Follow instructions below to connect w...

Страница 4: ...d is required refer to Table 2 for the proper 3 conducter heavy duty cord required Do not exceed the amperage ratings of the extension cord Undersized extension cords result in excessive drops in voltage which cause the electric motors to generate excessive heat This condition results in inefficient motor operation and premature motor failure WHICH WILL VOID THE WARRANTY Table 1 Electrical require...

Страница 5: ...hes may interfere with the air flow An attempt should be made to locate the unit in such a manner that interruption of the air pattern is held to a minimum Multiple units may be required to cover larger areas When the COOL SPACE unit is placed near a wall or other vertical obstruction it is recommended that there be a space of at least 1 metre between the back pad side of the unit and the obstruct...

Страница 6: ... without proper water treatment will create mineral deposit build up causing the pump to fail which is NOT COVERED BY WARRANTY Pump is equipped with a LOW WATER CUT OFF which may take up to 5 minutes to reset each time the power is turned on 5 0 Maintenance and storage ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance on the unit Failure to do so may ...

Страница 7: ...with either a towel or wet dry vacuum 6 Check belt for tightness if applicable 7 Remove the water spray bar and its plug Insure holes are free of debris 8 Reinstall pads and pad retainer 9 Reinstall rear guard if applicable To keep the COOL SPACE unit operating at peak efficiency ensure that the cooling pads are kept clean and dust free Dust and other particles have an adverse effect on the media ...

Страница 8: ... system has a problem you must define the associated problem e g the pump is not running Although this might seem a bit simplified several things may cause this particular problem So while defining the problem a careful check of all systems should be made to fully understand the extent of the problem If you have a complete understanding of all of the systems of the COOL SPACE unit and how they dep...

Страница 9: ...xtension cord Replace motor Upgrade power supply Replace with heavier cord Motor overheating and shutting off Restarting several minutes later Extension cord gauge too small Inlet air obstructed or too close to wall Faulty motor Loose belt Replace with heavier cord Provide minimum 1 metre inlet clearance Replace motor Tighten belt Fan motor won t run and switch makes soft clicking sound Switch mak...

Страница 10: ...sure is too high to allow float valve to shutoff 8 bar max Float valve is not seating properly Tighten connections and or replace hose washers Reduce water pressure by adding an inline reducer Check float valve Replace float orifice Check all hoses for leaks Water spitting from the unit Flow control Cracked Hose Valve Assembly Hose connection loose Reduce flow Replace Hose Valve Assembly Tighten h...

Страница 11: ...e running Object s in impellor impellor loose Pump bearings bad Remove object s Replace pump Breaker trips or fuse blows when switch is turned on Check power cord length and breaker rating Check for locked up pump Refer to page 2 for unit amperage draw and to determine required cord gauge Replace pump Pump won t run and power is available Pump is functional Make certain switch is working Is water ...

Страница 12: ...e new fan assembly 4 Secure with 4 nuts and bolts 5 Replace any wire ties that were removed when taking out the old fan assembly 6 Replace the black motor wiring plate AVALANCHE CS6 36 Series Variable Speed Direct Drive Models 1 Remove cap off rear of motor Disconnect wires Clip wire ties 2 Remove 4 fan mounting bolts from the front Support fan to ensure it doesn t fall 3 Pull the fan out of the u...

Страница 13: ...tly until the belt is tight but not tight enough to overload the motor then tighten the four bracket bolts 9 Replace the motor wires as marked from step 5 Replace wire ties to prevent cord from getting in fan blade 10 Replace motor wiring cover plate and inspect to be certain that the rubber seal is properly seated 11 Replace cooling pads and guards and reconnect power and test motor Pump Replacem...

Страница 14: ...u may fill out the warranty form supplied with your unity and fax it to 001 317 485 0118 or register online at www cool space com 7 2 Warranty parts Warranty replacement parts are available through your local distributor or supplier where you purchased your COOL SPACE unit If you have any questions or concerns please contact us direct at 001 317 577 0337 or at sales cool space com Please have your...

Страница 15: ...ssembly with Motor for GLACIER CS M36V 220 90cm 36 Variable Speed 60HZ for AVALANCHE CS M48 2B 60 220 120cm 48 Two Speed 60 HZ for BLIZZARD Switches CS E110 On Off Pump Single Speed Fan CS E111 Two Speed CS E180 Variable Speed CS6 36 VD 60HZ for AVALANCHE CS E199 VD 220 230 VD Controller for GLACIER Pump CS E173 1 CS5 16 VD CS6 36 VD CS5 48 2B 20cm 8 Pads CS H610 CS5 16 VD 2 required for GLACIER C...

Страница 16: ...nal Sales Office PO Box 6916 Bridgnorth WV16 9ED UK 00 44 7979 243154 www cool space com simon hartles cool space com DISTRIBUTOR Disposal This symbol on the product indicates that the appliance cannot be collection point for electric and electronic appliances ...

Отзывы: