Advanced Radiant Systems COOL-SPACE CS5-16 Скачать руководство пользователя страница 13

11 

 

6.2 Repair procedures (continued) 

BLIZZARD (CS5-48) Belt Drive Models 

1.  Remove the motor wiring plate and disconnect motor wires. Mark each wire with a 

marker that will allow easy matching when new motor is installed. (see section 5.1 for 
pad removal instructions) 

2.  Loosen the four bolts that fasten the motor to the bracket. This will allow the removal 

of the motor. 

3.  Remove the motor pulley by loosening the set screw and slide the pulley off. 

4.  Install the pulley onto the new motor and slightly tighten the set screw. 

5.  Place new motor onto the mounting bracket and reinstall the four mounting bolts and 

tighten. 

6.  Visually align the motor pulley and fan pulley by using the belt as a reference. Adjust 

the motor pulley in or out to align. Tighten the motor pulley. 

7.  Loosen the four (4) bolts that secure the mounting bracket to the upright. 

8.  Lower the bracket slightly until the belt is tight (but not tight enough to overload the 

motor), then tighten the four bracket bolts. 

9.  Replace the motor wires as marked from step #5. Replace wire ties to prevent cord 

from getting in fan blade. 

10. Replace motor wiring cover plate and inspect to be certain that the rubber seal is 

properly seated.  

11. Replace cooling pads and guards and reconnect power and test motor. 

 

Pump Replacement (All Models) 

1.  Disconnect hose from pump. 

2.  Remove pump bracket. 

3.  Remove the 2 screws from the top of the electrical cord and unplug the cord by 

pulling straight up from the top of the pump. 

4.  Remove pump from water sump and install new pump. Reverse the above 

procedures to reconnect the wiring, pump bracket and the hose. Secure wires to fan 
frame with wire ties to clear the fan blades. 

5.  Reinstall cooling pads and guards, reconnect power and test pump. 

 

6.3 Technical support 

Technical support and service is available directly from your distributor or  
 

COOL-

SPACE

®

 Technical Support Hot Line at 001-317-577-0337 

Visit: 

www.cool-space.com

 

Email: 

[email protected]

 

 

 

 

Содержание COOL-SPACE CS5-16

Страница 1: ...16 CS6 36 CS5 48 220V 60HZ GLACIER AVALANCHE BLIZZARD IMPORTANT SAFETY INFORMATION INSIDE Serious Injury or death possible Read understand and follow all safety information and instructions in the manual before using or servicing this product ...

Страница 2: ... adjusting the water flow 4 5 0 Maintenance and storage 4 5 1 Removing the cooling media accessing the inside of the unit 4 5 2 Daily maintenance 4 5 3 Periodic maintenance 5 5 4 Storage 5 6 0 Troubleshooting Repair 6 6 1 Troubleshooting 6 9 6 2 Repair procedures 10 11 6 3 Technical support 11 7 0 Warranty 12 7 1 Warranty form 12 7 2 Warranty parts 12 7 3 Optional accessories and replacement parts...

Страница 3: ...ger units are shipped on a wooden skid with a cardboard cover and lid The cardboard cover simply lifts off the COOL SPACE unit The cooler must be lifted off the wooden skid 3 0 Set up of the COOL SPACE unit The COOL SPACE unit is factory tested and ready to use The unit should be placed on a level surface and the castors locked to prevent inadvertent movement Follow instructions below to connect w...

Страница 4: ...d is required refer to Table 2 for the proper 3 conducter heavy duty cord required Do not exceed the amperage ratings of the extension cord Undersized extension cords result in excessive drops in voltage which cause the electric motors to generate excessive heat This condition results in inefficient motor operation and premature motor failure WHICH WILL VOID THE WARRANTY Table 1 Electrical require...

Страница 5: ...hes may interfere with the air flow An attempt should be made to locate the unit in such a manner that interruption of the air pattern is held to a minimum Multiple units may be required to cover larger areas When the COOL SPACE unit is placed near a wall or other vertical obstruction it is recommended that there be a space of at least 1 metre between the back pad side of the unit and the obstruct...

Страница 6: ... without proper water treatment will create mineral deposit build up causing the pump to fail which is NOT COVERED BY WARRANTY Pump is equipped with a LOW WATER CUT OFF which may take up to 5 minutes to reset each time the power is turned on 5 0 Maintenance and storage ELECTRICAL SHOCK HAZARD Disconnect the power supply before performing any service or maintenance on the unit Failure to do so may ...

Страница 7: ...with either a towel or wet dry vacuum 6 Check belt for tightness if applicable 7 Remove the water spray bar and its plug Insure holes are free of debris 8 Reinstall pads and pad retainer 9 Reinstall rear guard if applicable To keep the COOL SPACE unit operating at peak efficiency ensure that the cooling pads are kept clean and dust free Dust and other particles have an adverse effect on the media ...

Страница 8: ... system has a problem you must define the associated problem e g the pump is not running Although this might seem a bit simplified several things may cause this particular problem So while defining the problem a careful check of all systems should be made to fully understand the extent of the problem If you have a complete understanding of all of the systems of the COOL SPACE unit and how they dep...

Страница 9: ...xtension cord Replace motor Upgrade power supply Replace with heavier cord Motor overheating and shutting off Restarting several minutes later Extension cord gauge too small Inlet air obstructed or too close to wall Faulty motor Loose belt Replace with heavier cord Provide minimum 1 metre inlet clearance Replace motor Tighten belt Fan motor won t run and switch makes soft clicking sound Switch mak...

Страница 10: ...sure is too high to allow float valve to shutoff 8 bar max Float valve is not seating properly Tighten connections and or replace hose washers Reduce water pressure by adding an inline reducer Check float valve Replace float orifice Check all hoses for leaks Water spitting from the unit Flow control Cracked Hose Valve Assembly Hose connection loose Reduce flow Replace Hose Valve Assembly Tighten h...

Страница 11: ...e running Object s in impellor impellor loose Pump bearings bad Remove object s Replace pump Breaker trips or fuse blows when switch is turned on Check power cord length and breaker rating Check for locked up pump Refer to page 2 for unit amperage draw and to determine required cord gauge Replace pump Pump won t run and power is available Pump is functional Make certain switch is working Is water ...

Страница 12: ...e new fan assembly 4 Secure with 4 nuts and bolts 5 Replace any wire ties that were removed when taking out the old fan assembly 6 Replace the black motor wiring plate AVALANCHE CS6 36 Series Variable Speed Direct Drive Models 1 Remove cap off rear of motor Disconnect wires Clip wire ties 2 Remove 4 fan mounting bolts from the front Support fan to ensure it doesn t fall 3 Pull the fan out of the u...

Страница 13: ...tly until the belt is tight but not tight enough to overload the motor then tighten the four bracket bolts 9 Replace the motor wires as marked from step 5 Replace wire ties to prevent cord from getting in fan blade 10 Replace motor wiring cover plate and inspect to be certain that the rubber seal is properly seated 11 Replace cooling pads and guards and reconnect power and test motor Pump Replacem...

Страница 14: ...u may fill out the warranty form supplied with your unity and fax it to 001 317 485 0118 or register online at www cool space com 7 2 Warranty parts Warranty replacement parts are available through your local distributor or supplier where you purchased your COOL SPACE unit If you have any questions or concerns please contact us direct at 001 317 577 0337 or at sales cool space com Please have your...

Страница 15: ...ssembly with Motor for GLACIER CS M36V 220 90cm 36 Variable Speed 60HZ for AVALANCHE CS M48 2B 60 220 120cm 48 Two Speed 60 HZ for BLIZZARD Switches CS E110 On Off Pump Single Speed Fan CS E111 Two Speed CS E180 Variable Speed CS6 36 VD 60HZ for AVALANCHE CS E199 VD 220 230 VD Controller for GLACIER Pump CS E173 1 CS5 16 VD CS6 36 VD CS5 48 2B 20cm 8 Pads CS H610 CS5 16 VD 2 required for GLACIER C...

Страница 16: ...nal Sales Office PO Box 6916 Bridgnorth WV16 9ED UK 00 44 7979 243154 www cool space com simon hartles cool space com DISTRIBUTOR Disposal This symbol on the product indicates that the appliance cannot be collection point for electric and electronic appliances ...