1
Signal Word Definitions
DANGER indicates an imminently hazardous situation which,
if not avoided,
WILL
result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided,
COULD
result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided,
MAY
result in minor or moderate injury.
IMPORTANT indicates a potentially hazardous situation
which, if not avoided,
MAY
result in property damage.
1.0 Introduction
COOL-
SPACE
®
is a patented and registered Trade Mark of Advanced Radiant Systems,
Inc. and manufactured in Indiana USA.
COOL-
SPACE
®
is a compact, self-contained, high-efficiency portable evaporative cooler
capable of lowering existing temperatures by as much as 15ºC.
2.0 Unpacking your COOL-SPACE
®
unit
Carefully examine the carton for damage before opening. If the carton is damaged notify the
shipping company immediately.
The CS5-16 units are shipped in a cardboard box. Open the top panel and lift the unit out.
The larger units are shipped on a wooden skid with a cardboard cover and lid. The
cardboard cover simply lifts off the COOL-
SPACE
®
unit. The cooler must be lifted off the
wooden skid.
3.0 Set-up of the COOL-SPACE
®
unit
The COOL-
SPACE
®
unit is factory tested and ready to use. The unit should be placed
on a level surface, and the castors locked to prevent inadvertent movement. Follow
instructions below to connect water and electrical supply.
3.1 Connecting the water supply
Do not connect the COOL-
SPACE
®
unit to any water source where water pressure exceeds 8
bar. This will cause permanent damage to the unit.
The COOL-
SPACE
®
unit comes equipped with a female garden hose water source
connection, with a pressure regulator attached. Attach the unit to a standard garden hose
outlet for a water source. The unit should not be attached to any water source with operating
pressure above 8 bar. Pressures above 8 bar must use a pressure regulator which may be
purchased at your local hardware store. Note: a female - ¾: to 22mm connection may be
required (not supplied) depending on local pipe sizing. If you have
purchased the optional
portable water tank, use a standard garden hose (not provided)
to connect the tank to
the cooler.