Integral stainless steel bypass sample
system significantly increases user
productivity. The bypass valve isolates
the sensor from high oxygen levels
when changing sample lines.
Technical Specifications *
Accuracy:
< 2% of FS range under constant conditions
Analysis Ranges:
0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% (CAL) FS
Auto-ranging or manual lock on a single range
Application:
Oxygen analysis in inert, helium, hydrogen, mixed and
acid (CO
2
) gas streams
Area Classification: General purpose
Calibration:
Max interval—3 months. Use certified span gas with O2
content (balance N2) approximating 80% of full scale
for fast 20-30 minute recovery to online use. Alterna-
tively, air calibrate with clean source of compressed or
ambient (20.9% O2) air on 0-25% range and allow 60
minutes on zero gas to recover to 10 ppm. For opti-
mum accuracy, calibrate one range higher than the
range of interest.
Compensation:
Temperature
Connections:
1/8" compression tube fittings
Controls:
Water resistant keypad; menu driven range selection,
calibration and system functions
Display:
Graphical LCD 2.75 x 1.375”; resolution .01 PPM
Enclosure:
Painted aluminum NEMA 4X, 8.6 x 9 x 3", 12 lbs.
Flow:
Not flow sensitive; recommended flow rate 2 SCFH
LED Indicators:
LOW BATT (72 hr. warning); CHARGE mode
Linearity:
> .995 over all ranges
Pressure:
Inlet - regulate to 5-30 psig to deliver 2 SCFH flow;
vent - atmospheric
Power:
Rechargeable battery, 60 day cycle, 8 hrs with pump
Recovery Time:
60 sec in air to < 10 PPM in < 1 hour on N
2
purge
Response Time:
90% of final FS reading in 10 seconds
Sample System:
Flow control and sample/bypass valves; flow indicator
Sensitivity:
< 0.5% of FS range
Sensor Model:
GPR-12-333 for non-acid (CO2) gas streams
XLT-12-333 for gas mixture with > 0.5% CO
2
Sensor Life:
24 months in < 1000 PPM O2 at 25ºC and 1 atm
Signal Output:
0-1V FS
Temp. Range:
5ºC to 45ºC (GPR sensor), -10
º
to 45
º
C (XLT sensor)
Warranty:
12 months analyzer; 12 months sensor
Wetted Parts:
Stainless steel
Optional Equipment
Carrying case with custom foam insert
Sample conditioning - pump, filter, scrubbers - contact factory
* Subject to change without notice.
2855 Metropolitan Place, Pomona, CA 91767 USA
♦
Tel: 909-392-6900, Fax: 909-392-3665, www.aii1.com, e-mail: [email protected] Rev 10/15
GPR-1200
Portable PPM O
2
Analyzer
Rechargeable Battery Powered
Advanced Sensor Technology
Fast Recovery to < 10 PPM from Exposure to Air
Unmatched Sensor Life, Warranty and Performance
Excellent Compatibility in 0-100% CO
2
Extended Operating Temperature –10
⁰
C
Sensitivity 0.5% Full Scale
Auto Ranging or Fixed Single
0-1 V Signal Output
Operates in Charging Mode
ISO 9001:2008 Certified
INTERTEK Certificate No. 485