40: Bar Code Invalid: Temperature Compensation
Digits 22 and 23 of the bar code have been decoded incorrectly.
41: Bar Code Invalid: Resistance Coefficient
Digit 18 of the bar code has been decoded incorrectly.
43: Bar Code Invalid: Regulation Mode.
Digit 12 of the bar code has been decoded incorrectly.
44: Bar Code Invalid: Fitting Size.
Digits 9, 10 and 11 of the bar code have been decoded incorrectly.
45: Bar Code Invalid: Cooling Time.
Digit 7 of the bar code has been decoded incorrectly.
46: Bar Code Invalid: Fusion Cycle Type.
Digit 5 of the bar code has been decoded incorrectly.
47: Bar Code Invalid: Energy Correction.
Digit 3 of the bar code has been decoded incorrectly.
48: Bar Code Invalid: Component Type.
Digits 1 and 2 of the bar code have been decoded incorrectly.
49: Bar Code Invalid: Check Digit.
Digit 24 of the bar code has been decoded incorrectly.
50: USB Memory: Disc full.
This fault will happen if the USB flash memory pen is full. Delete some files from the device.
51: USB Memory: File allocation table full.
This will happen if the USB flash memory pen’s file structure becomes fragmented.
Follow the instructions with Windows to defragment the memory pen.
52: USB Memory: File not found.
When performing a software upgrade, the required file was not found on the memory
drive. Reload the upgrade files onto the memory drive.
127: Power off failure.
If the power is turned off while the unit is welding, this fault will be recorded to the datalog.