Sweep System, Main Broom 234
Service Manual – Advance 7765 / Nilfisk CR1500
Troubleshooting
Problem
Cause
Correction
Main broom motor
not running.
Circuit breaker CB6 is
tripped.
Reset the circuit breaker.
No voltage to the Main
Broom Solenoid (2) valve.
• Check for continuity through the hopper and
hopper door “whisker” switches when the hopper
is down and the hopper door is closed. Repair the
wiring or replace the switch(es) as necessary.
• Check the Main Broom Switch function and repair/
replace as necessary.
• Check the wiring from the Main Broom Switch to
the Main Broom Solenoid (2) valve. There should
be 0 volts to the solenoid when the main broom
and dust control motors are off, and 12 VDC to the
solenoid when the motors are on.
Main Broom Solenoid (2)
valve not operating correctly.
1. Check the solenoid coil resistance. If not 7.2
ohms ±10%, replace the coil. Also see the
Main
Broom Sweep System Wiring Diagram
.
2. If the coil resistance is within spec, check for
binding or a mechanical problem. Repair or
replace the solenoid valve as necessary.
Specifications
Component
Specifications
Hydraulic Broom Drive Motor
Displacement – 4.5 CIR
Main Broom Solenoid (2) Valve
Voltage – 12 volts
Nominal Coil Resistance – 7.2 Ohms
Initial current draw – 1.67 amps
Содержание 56514925
Страница 28: ...General Information 28 Service Manual Advance 7765 Nilfisk CR1500 Maintenance Item Locations ...
Страница 71: ...Engine Harness GM 3 0L Gas p n 56380222 Electrical System 71 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 72: ...Engine Harness GM 3 0L LPG p n 56380221 Electrical System 72 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 74: ...Engine System common Electrical System 74 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 75: ...Engine Frame Side System Mitsubishi Diesel Electrical System 75 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 76: ...Engine Frame Side System GM Gas Electrical System 76 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 77: ...Engine Frame Side System GM LPG Electrical System 77 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 89: ...Engine System Diesel 89 Service Manual Advance 7765 Nilfisk CR1500 Starter Relay ...
Страница 100: ...Engine System Gasoline LPG 100 Service Manual Advance 7765 Nilfisk CR1500 Oil Pressure Sensor Ground Connection ...
Страница 113: ...Engine System Gasoline LPG 113 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 114: ...Engine System Gasoline LPG 114 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 115: ...Engine System Gasoline LPG 115 Service Manual Advance 7765 Nilfisk CR1500 ...