Squeegee System
213
Service Manual – Advance 7765 / Nilfisk CR1500
Troubleshooting
General Troubleshooting
Problem
Cause
Correction
Poor Water Pick-up.
The squeegee blades are
torn or worn.
Check and replace the blades as necessary.
The squeegee assembly is
out of adjustment.
Readjust the squeegee. (Refer to the Instructions for
Use.)
The squeegee
deck will not extend
downward.
No voltage to the Squeegee
Lock Up (10) solenoid valve.
1. Check circuit breaker CB7 and reset if necessary.
2. Check the wiring from CB7 to the Squeegee Lock
Up (10) solenoid valve and repair as necessary.
The Squeegee Lock Up
(10) solenoid valve in the
Cylinder Control Valve not
opening when energized
(stuck closed).
1. Check the coil resistance of the Squeegee Lock
Up (10) solenoid valve. If the coil resistance is not
9.8 ohms ±10%, replace the coil.
2. If the coil resistance is within spec, check for
binding or a mechanical problem. Repair or
replace the valve as necessary.
The squeegee is binding.
Check for binding or damage in the squeegee lift
mechanism and mounting hardware and correct as
necessary.
Squeegee will not
retract upward.
No voltage to the Squeegee
Cylinder Solenoid (7) in the
Cylinder Control Valve.
1. Check circuit breaker CB8 and reset if necessary.
2. Check the continuity from CB8 through the
Squeegee Blade Switch to the Squeegee
Cylinder Solenoid (7). There should be 12 VDC
to the Squeegee Cylinder Solenoid (7) with the
Squeegee Blade Switch in the squeegee-raise
position.
The Squeegee Cylinder
Solenoid (7) in the Cylinder
Control Valve not switching
when energized.
1. Check the coil resistance of the Squeegee
Cylinder Solenoid (7). If the coil resistance is not
9.8 ohms ±10%, replace the coil.
2. If the coil resistance is within spec, check for
binding or a mechanical problem. Repair or
replace the valve as necessary.
The squeegee is binding.
Check for binding or damage in the squeegee lift
mechanism and mounting hardware and correct as
necessary.
Squeegee will not
rise when the drive
pedal is moved to
the reverse position.
No voltage to the Squeegee
Cylinder Solenoid (7) in the
Cylinder Control Valve.
• Check the drive pedal reverse sensor function.
The drive pedal reverse sensor should provide 12
VDC to the reverse relay coil when the drive pedal
is moved to the reverse position.
• Check the reverse relay function The reverse relay
should switch to position 87 and provide 12 VDC
to the Squeegee Cylinder Solenoid (7) when the
drive pedal is moved to the reverse position.
Содержание 56514925
Страница 28: ...General Information 28 Service Manual Advance 7765 Nilfisk CR1500 Maintenance Item Locations ...
Страница 71: ...Engine Harness GM 3 0L Gas p n 56380222 Electrical System 71 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 72: ...Engine Harness GM 3 0L LPG p n 56380221 Electrical System 72 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 74: ...Engine System common Electrical System 74 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 75: ...Engine Frame Side System Mitsubishi Diesel Electrical System 75 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 76: ...Engine Frame Side System GM Gas Electrical System 76 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 77: ...Engine Frame Side System GM LPG Electrical System 77 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 89: ...Engine System Diesel 89 Service Manual Advance 7765 Nilfisk CR1500 Starter Relay ...
Страница 100: ...Engine System Gasoline LPG 100 Service Manual Advance 7765 Nilfisk CR1500 Oil Pressure Sensor Ground Connection ...
Страница 113: ...Engine System Gasoline LPG 113 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 114: ...Engine System Gasoline LPG 114 Service Manual Advance 7765 Nilfisk CR1500 ...
Страница 115: ...Engine System Gasoline LPG 115 Service Manual Advance 7765 Nilfisk CR1500 ...