Chapter 3. Operation
61200.076L2-1
TSU 600 User Manual
55
*
Figure 3-10
Network Interface Error Type
The asterisk (
*
) above an item indicates the type of
errors detected. The error types are the following:
CRC
CRC-6 bit errors based on the FDL. This is
valid only in ESF mode.
BPV
Bipolar violations.
XS0
Excess zeros.
FER
Framing errors.
Active Alarms
This menu item displays a list of current alarms
reported by either the base controller or any of the
ports. If no alarms are current, using this menu item
displays
End of List
.
This display includes two lines of text. The top line is
the alarm source. The bottom line is the alarm mes-
sage. A list of alarm messages is found in the appen-
dix,
TSU 600 System Messages.
With the cursor on Main menu item 1)STATUS,
activate the menu with
Enter
or number
1
. The unit
displays the first two Status submenu items with the
cursor on
1)NI PERF RPTS.
With the
arrows
or number
3
, select 3)Alarms.
Activate the selection with
Enter
or number
3
. The
unit begins the display of alarm messages and their
identified source. See Figure 3-11. Continue with
standard operating procedures to exit the display.
Содержание TSU 600
Страница 1: ...61200 076L2 1B July 1997 TSU 600 USER MANUAL Part Number 1200076L2 1200076L2 DC...
Страница 4: ...Table of Contents...
Страница 96: ...Chapter 3 Operation 84 TSU 600 User Manual 61200 076L2 1...
Страница 103: ...Chapter 4 Example Operations 61200 076L2 1 TSU 600 User Manual 91 Figure 4 4 First Two Network NI Menu Items...
Страница 118: ...Chapter 4 Example Operations 106 TSU 600 User Manual 61200 076L2 1...
Страница 126: ...Appendix C System Configuration Charts 114 TSU 600 User Manual 61200 076L2 1...
Страница 128: ...Appendix D TSU 600 System Messages 116 TSU 600 User Manual 61200 076L1 1...