Chapter 3. Operation
61200.129L1-1
TSU 120 User Manual
69
CREATE TEMP
This creates a map by defining a port or Idle for all
DS0s. Any or all of the DS0s can also be designated
for Passthru if a secondary interface capable of
Passthru is present. When 2)CREATE TEMP is
selected, all DS0s are set to Idle, and those in use are
set to the proper port.
A sample selection follows:
DS0: 01 to 24
PASSTHRU: Y for Yes
N for No
PORT: IDLE, TST, 0.1 NX56/64(+ other Ports)
TST is used to designate which DS0s are used for QRSS
testing when activated under the 4)TEST Menu. When not
used for testing, the TST designation is identical to IDLE.
With the cursor on 2)CREATE TEMP, press Enter. The
unit displays the selection screen with the cursor
positioned on the first selection DS0 number. See
Figure 3-15.
Select DS0 Number
Passthru
Yes or No
Select Port
Figure 3-15
CREATE TEMP Selection Screen
Use either the scroll method or numbers to enter the
DS0 number (do not mix the use of the keys). Pressing
Enter
completes the selection and moves the cursor to
the next field, Passthru. Scroll to change, Y for Yes or
N
for No. Press Enter to complete the selection and
move the cursor to the next field, PORT.
Содержание TSU 120
Страница 1: ...TSU 120 PART NUMBER 1200129L1 USER MANUAL 61200 129L1 1A July 1997...
Страница 52: ...Chapter 2 Installation 38 TSU 120 User Manual 61200 129L1 1...
Страница 111: ...Chapter 4 Example Operations 61200 129L1 1 TSU 120 User Manual 97 Figure 4 4 First Two Network NI Menu Items...
Страница 132: ...Appendix C System Configuration Charts 118 TSU 120 User Manual 61200 129L1 1...
Страница 138: ...Appendix D TSU 120 System Messages 124 TSU 120 User Manual 61200 129L1 1...