background image

61182118L1-5B

Issue 2, July 2004

    9

Cross-Connect Map

The purpose of the cross-connect map (

Table 4 

on 

page 5) is to allocate the time slots (TS0s) from the 
SHDSL loop to user ports (E1) and configure framing. 
The cross-connect maps can be accessed via the VT100 
terminal screens. 

1. select “2,” Provisioning, from the Main Menu

2. select “1,” Unit Options, 

3. select “2,” Cross Connect Map. 

The cross-connect map is split down the middle in two 
sections. The left section of the map lists the SHDSL 
time slots and right section of the map lists the G.703 
time slots. The user builds a new pending map before 
making it active with the apply key. The options listed 

at the bottom of the screen allow the user to setup and 
manipulate the time slots. The statement at the bottom 
of the screen indicates the framing status. Time slot 
configuration options are described in 

Table 4

.

Cross-connect commands are described in 

Table 5

.

Typical Applications 

Framed Full E1 Service is set up using the quick key 
“G,” and then selecting “A” to save the changes.

Unframed Full E1 Service is set up using the quick key 
“G,” entering “1” in both the SHDSL TS0 slot and the 
G.703 TS0 slot, and then selecting “A” to save the 
changes. 

Table 4.  Cross-Connect Map Timeslot Assignments

Option

Description

0. Idle

If a time slot is set for idle, an idle code is inserted. The pattern will always be FF hex (all 
1s) toward the SHDSL network. The idle pattern out the G.703 interface is programmable 
under the G.703 option. The default is FF hex (all 1s).

1. G.703 Service

The selected time slot will carry G.703 service (Refer to the 

Full G.703 Services 

subsection for more information). 

32. G.704 Framing

This option enables three different framing configurations. Framing is always set in the 
first time slot (TS0). The framing will be locally generated if 32 is entered in the G.703 
TS0 slot only. If 32 is entered in the G.703 TS0 and the SHDSL TS0, then the framing 
will be passed transparently between the G.703 and SHDSL ports. If values other than 32 
are assigned to both the SHDSL TS0 slot and G.703 TS0 slot then the operation is G.703 
unframed (if other G.703 service values are assigned to the G.703 time slots).

Table 5.  Cross-Connect Map Commands

Command

Description

A. Apply New Map

This command saves and activates any changes made by the user.

C. Cancel Changes

This command will undo any changes made by the user since the last saved 
configuration. The new pending map will revert to the currently active time slot 
assignments.

G. Full G.703
     Service

If this quick key command is selected, the cross-connect map will automatically 
configure the time slots for Full G.703 service, and the framing will be set for 
transparent. Refer to the Typical Applications subsection for more information.

Tab. Select SHDSL 
or G.703 Time Slots

The tab key moves the cursor between the SHDSL and G.703 sections of the cross-
connect map.

Arrow Keys Move 
Cursor

The arrow keys allow movement between the individual time slots.

Содержание Total Access SHDSL LTU

Страница 1: ...for the ADTRAN Total Access 2 Wire 4 Wire SHDSL Line Termination Unit LTU P N 1182118L1 Figure 1 illustrates the 2W 4W SHDSL LTU front panel Revision History This is the second issue of this practice...

Страница 2: ...nals are transmitted received via the 64 pin backplane amphenol connectors The G 703 signal is transmitted to the network side via Pair 8 and the G 703 signal is received from the network side via con...

Страница 3: ...nt panel DB 9 connector that supplies an RS 232 interface for connection to a controlling terminal The pinout of the DB 9 is illustrated in Figure 2 Figure 2 RS 232 DB 9 Pin Assignments The terminal i...

Страница 4: ...successful login access the Total Access Main Menu and select option 4 Access Modules Then choose the slot number of the desired 2W 4W SHDSL LTU module The 2W 4W SHDSL LTU Main Menu is shown in Figur...

Страница 5: ...ons 2 SHDSL Options 1 In Service 2 Out of Service Unassigned 3 Out of Service Maintenance 1 Internal Clock 2 G 703 RX Clock 1 Disabled 2 Enabled 1 Disabled 2 Enabled 4 Loop Attenuation Alarm Threshold...

Страница 6: ...3 BERT Tx Pattern 4 BERT Tx Pattern Polarity 1 Loopback Types 1 SHSDL Loopback Type Dual Sided 2 G 703 Loopback Type Dual Sided 0 Disabled 1 999 Timeout in Minutes 2 2047 3 2e15 1 4 QRSS 1 ALT 1 Norma...

Страница 7: ...arms Disabled Enabled Disabled NTU Auto Provisioning Disabled Enabled Disabled SHDSL Options Interface Mode 2 wire 4 wire 2 wire Payload Rate kbps Enter a new value for N from 3 to 32 where Payload Ra...

Страница 8: ...d Enabled Enabled E bit Generation Disabled Enabled Disabled PM Thresholds See below ES 15 Minute Alarm Threshold Disabled 1 to 900 Alarm Threshold Disabled SES 15 Minute Alarm Threshold Disabled 1 to...

Страница 9: ...etwork The idle pattern out the G 703 interface is programmable under the G 703 option The default is FF hex all 1s 1 G 703 Service The selected time slot will carry G 703 service Refer to the Full G...

Страница 10: ...n progress The source column identifies the originator of the BERT in progress INACTIVE This BERT is not currently in progress After selecting a BERT type from the Test Screen the BERT Screen will app...

Страница 11: ...tiated at the LTU and provides bidirectional loopback at the NTU Local Network Transparent Loopback Provides a loopback at the LTU in the network direction Data is passed transparently to the customer...

Страница 12: ...mer Nontransparent Loopback Provides a loopback at the LTU in the customer direction AIS signal is injected into the network side Remote Customer Nontransparent Loopback Initiated at the LTU and provi...

Страница 13: ...nce SHDSL per ITU G991 2 2 wire mode 192 kbps to 2 048 Mbps 4 wire mode 400 kbps to 2 064 Mbps Refer to ITU 991 2 Annex B Performance Requirements 64 kbps to 1 984 Mbps TC PAM Internal clock internal...

Страница 14: ...tomers can also receive a copy of the warranty via ADTRAN s toll free faxback server at 877 457 5007 Request Document 414 for the U S and Canada Carrier Networks Equipment Warranty Request Document 90...