2    

Issue 2, July 2004

61182118L1-5B

Features

The basic features of the Total Access 2W/4W SHDSL 
LTU (P/N 1182118L1) include the following:

• BAU interface with 4-wire SHDSL operation

• Basic loopback test on a SHDSL loop basis

• Full management support of the ADTRAN SHDSL 

4-wire NTU

• Management under SNMP via SCU module

• Flash programmable

• Supports remote NTU software downloads

• Data throughput is adjustable from 192 kbps to 

2048 kbps in 64 k increments

• SHDSL loop performance monitoring

• SHDSL loop attenuation and signal-to-noise ratio 

records

Compliance

Table 1

 shows the compliance codes for the 2W/4W 

SHDSL LTU. The 2W/4W SHDSL LTU is NRTL 
listed to the applicable UL standards. The 2W/4W 
SHDSL LTU is to be installed in a restricted access 
location and in a Type “B” or “E” enclosure only. 

This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions: 

1. This device may not cause harmful interference.

2. This device must accept any interference received, 

including interference that may cause undesired 
operation.

Changes or modifications not expressly approved by 
ADTRAN could void the user’s authority to operate this 
equipment.

Connections

The SHDSL LTU module fits any one of the 1-28 slots 
in the Total Access 3000 chassis or any one of the 1-22 
slots in the Total Access 3010 chassis. Power and alarm 
signals are provided to the card through the backplane 
of the shelf.

The G.703 and SHDSL signals are transmitted/received 
via the 64-pin backplane amphenol connectors. The 
G.703 signal is transmitted to the network side via “Pair 
8,” and the G.703 signal is received from the network 
side via connector “Pair 7.” The SHDSL signal is trans-
mitted to and from the customer-side NTU via 
connector “Pair 2” for 2-wire mode and “Pair 2” plus 
“Pair 1” for the 4-wire mode.

3. INSTALLATION

After unpacking the Total Access 2W/4W SHDSL 
LTU, inspect it for damage. If damage has occurred, file 
a claim with the carrier, then contact ADTRAN 
Customer Service. Refer to the 

Warranty and Customer 

Service

 section for further information. If possible, keep 

the original shipping container for returning the 2W/4W 
SHDSL LTU for repair or for verification of shipping 
damage.

Shipping Contents

The contents include the following items:

• 2W/4W SHDSL LTU

• 2W/4W SHDSL LTU Job Aid

CAUTION

Electronic modules can be damaged by ESD.
When handling modules, wear an antistatic
discharge wrist strap to prevent damage to
electronic components. Place modules in
antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.

Instructions for Installing the Module

To install the 2W/4W SHDSL LTU, perform the 
following steps:

1. If present, remove the Access Module Blank (P/N 

1181953L1) from the appropriate access module 
slot of the Total Access 3000/3010 chassis.

Table 1.  Compliance Codes

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Содержание Total Access SHDSL LTU

Страница 1: ...for the ADTRAN Total Access 2 Wire 4 Wire SHDSL Line Termination Unit LTU P N 1182118L1 Figure 1 illustrates the 2W 4W SHDSL LTU front panel Revision History This is the second issue of this practice...

Страница 2: ...nals are transmitted received via the 64 pin backplane amphenol connectors The G 703 signal is transmitted to the network side via Pair 8 and the G 703 signal is received from the network side via con...

Страница 3: ...nt panel DB 9 connector that supplies an RS 232 interface for connection to a controlling terminal The pinout of the DB 9 is illustrated in Figure 2 Figure 2 RS 232 DB 9 Pin Assignments The terminal i...

Страница 4: ...successful login access the Total Access Main Menu and select option 4 Access Modules Then choose the slot number of the desired 2W 4W SHDSL LTU module The 2W 4W SHDSL LTU Main Menu is shown in Figur...

Страница 5: ...ons 2 SHDSL Options 1 In Service 2 Out of Service Unassigned 3 Out of Service Maintenance 1 Internal Clock 2 G 703 RX Clock 1 Disabled 2 Enabled 1 Disabled 2 Enabled 4 Loop Attenuation Alarm Threshold...

Страница 6: ...3 BERT Tx Pattern 4 BERT Tx Pattern Polarity 1 Loopback Types 1 SHSDL Loopback Type Dual Sided 2 G 703 Loopback Type Dual Sided 0 Disabled 1 999 Timeout in Minutes 2 2047 3 2e15 1 4 QRSS 1 ALT 1 Norma...

Страница 7: ...arms Disabled Enabled Disabled NTU Auto Provisioning Disabled Enabled Disabled SHDSL Options Interface Mode 2 wire 4 wire 2 wire Payload Rate kbps Enter a new value for N from 3 to 32 where Payload Ra...

Страница 8: ...d Enabled Enabled E bit Generation Disabled Enabled Disabled PM Thresholds See below ES 15 Minute Alarm Threshold Disabled 1 to 900 Alarm Threshold Disabled SES 15 Minute Alarm Threshold Disabled 1 to...

Страница 9: ...etwork The idle pattern out the G 703 interface is programmable under the G 703 option The default is FF hex all 1s 1 G 703 Service The selected time slot will carry G 703 service Refer to the Full G...

Страница 10: ...n progress The source column identifies the originator of the BERT in progress INACTIVE This BERT is not currently in progress After selecting a BERT type from the Test Screen the BERT Screen will app...

Страница 11: ...tiated at the LTU and provides bidirectional loopback at the NTU Local Network Transparent Loopback Provides a loopback at the LTU in the network direction Data is passed transparently to the customer...

Страница 12: ...mer Nontransparent Loopback Provides a loopback at the LTU in the customer direction AIS signal is injected into the network side Remote Customer Nontransparent Loopback Initiated at the LTU and provi...

Страница 13: ...nce SHDSL per ITU G991 2 2 wire mode 192 kbps to 2 048 Mbps 4 wire mode 400 kbps to 2 064 Mbps Refer to ITU 991 2 Annex B Performance Requirements 64 kbps to 1 984 Mbps TC PAM Internal clock internal...

Страница 14: ...tomers can also receive a copy of the warranty via ADTRAN s toll free faxback server at 877 457 5007 Request Document 414 for the U S and Canada Carrier Networks Equipment Warranty Request Document 90...

Отзывы: