background image

 Unit Installation

NetVanta 3100 Series Hardware Installation Guide

 26

Copyright © 2015 ADTRAN, Inc.

61700600L2-34C

3.

UNIT INSTALLATION

The instructions and guidelines provided in this section cover hardware installation topics, such as 
tabletop, wall, and rack mounting and powering the units. These instructions are presented as follows:

Mounting Options on page 26

Supplying Power to the Unit on page 34

For information on router configuration for a specific application, refer to the configuration guides provided on 
the 

ADTRAN Support Community

. For details on the command line interface (CLI), refer to the 

AOS 

Command Reference Guide

. All other related documents are also available online at 

http://supportforums.adtran.com

Tools Required

The customer-provided tools required for the hardware installation of the NetVanta 3100 Series are:

Ethernet cable

Phillips-head screwdriver

Mounting Options

All of the NetVanta 3100 Series units can be installed in a wallmount or tabletop configuration. The 
NetVanta 3140 (P/N 1700341F1) can be mounted in a rack alone or with two units side by side using the 
optional dual mounting tray (P/N 1700508F1).

Tabletop Mounting

For tabletop mounting, place the unit on a level surface within easy reach of an electrical outlet.

To prevent electrical shock, do not install equipment in a wet location or during a 
lightning storm.

Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN unit 
directly to Ethernet cables that run outside the building in which the unit is housed 
will void the user's warranty and could create a fire or shock hazard. To connect an 
ADTRAN unit to Ethernet cables that run outside the building, ADTRAN's Ethernet 
Port Protection Device (EPPD) (P/N 1700502G1) must be connected between the 
unit and the outside plant cable. Use of any Ethernet protector other than ADTRAN's 
for this purpose will void the user's warranty.

NetVanta 3140 units have a Kensington lock slot that accepts a lock and cable security 
device. Consult the manual shipped with your Kensington lock for installation instructions.

Содержание NetVanta 3140 Desktop

Страница 1: ...nta 3130 Annex A with DBU 1700611G2 NetVanta 3130 Annex A with DBU 1700612G2 NetVanta 3130 Annex B without DBU 1700340F1 NetVanta 3140 Desktop 1700341F1 NetVanta 3140 1700508F1 19 inch Dual Mounting T...

Страница 2: ...this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchase...

Страница 3: ...2 34C Copyright 2015 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provi...

Страница 4: ...ot dispose of batteries in a fire They may explode Check with local codes for special disposal instructions 5 The socket outlet shall be installed near the equipment and shall be easily accessible If...

Страница 5: ...arranty information The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning 5 This unit...

Страница 6: ...ion que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas cinq Canadian Emissions Requirements This digital apparatus does not exceed the Class A limits for radio noi...

Страница 7: ...19 NetVanta 3140 Series 20 NetVanta 3140 Features and Specifications 20 NetVanta 3140 Shipping Contents 21 NetVanta 3140 Desktop Front Panel Design 21 NetVanta 3140 Desktop Rear Panel Design 22 NetVa...

Страница 8: ...Table of Contents NetVanta 3100 Series Hardware Installation Guide 8 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Страница 9: ...3130 with DBU Rear Panel Layout 19 Figure 8 NetVanta 3130 without DBU Rear Panel Layout 19 Figure 9 NetVanta 3140 Desktop Front Panel Layout 21 Figure 10 NetVanta 3140 Desktop Rear Panel Layout 22 Fig...

Страница 10: ...List of Figures NetVanta 3100 Series Hardware Installation Guide 10 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Страница 11: ...Panel LEDs 24 Table 2 NetVanta 3140 Series Front Panel LEDs 25 Table A 1 10 100Base T Ethernet Port Pinouts 37 Table A 2 1000Base T Gigabit Ethernet Port Pinouts NetVanta 3140 37 Table A 3 Console Po...

Страница 12: ...List of Tables NetVanta 3100 Series Hardware Installation Guide 12 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Страница 13: ...Installation on page 26 For additional information on mounting options and suppling power to the unit refer to the following sections Mounting Options on page 26 Supplying Power to the Unit on page 34...

Страница 14: ...ted analog modem for dial backup or remote management 1700600L2 only ADTRAN Operating System AOS command line interface CLI User friendly web based graphical user interface GUI Standards based eBGP iB...

Страница 15: ...m with the carrier and contact ADTRAN Customer Service refer to the Support page on the ADTRAN website at http www adtran com support Shipments of the NetVanta 3120 include the following items NetVant...

Страница 16: ...ts The Ethernet port provides the following 10Base T or 100Base T with a single connector Auto negotiation CSMA CD IEEE 802 3 compatibility DBU Interface 1700600L2 only The NetVanta 3120 has a DBU por...

Страница 17: ...p to 25 Mbps Some models include an integrated analog modem for dial backup and management IPsec VPN support is included without further software upgrade The unit is powered by a 12 VDC power supply A...

Страница 18: ...deep penetration into the carton with sharp objects After unpacking the unit inspect it for possible shipping damage If the equipment has been damaged in transit immediately file a claim with the car...

Страница 19: ...BU Interface 1700610L2 only The NetVanta 3130 has a DBU port on the rear panel to provide analog V 90 dial backup See Table A 4 on page 38 for the DBU connector pinouts Factory Default Switch The NetV...

Страница 20: ...ure release IPsec VPN support is included with a further software upgrade NetVanta 3140 Features and Specifications The NetVanta 3140 offers the following features Three routed 10 100 1000Base T Ether...

Страница 21: ...n into the carton with sharp objects After unpacking the unit inspect it for possible shipping damage If the equipment has been damaged in transit immediately file a claim with the carrier and contact...

Страница 22: ...se Te 100Base T or 1000Base T via RJ 45 Auto negotiation CSMA CD IEEE 802 3 compatibility Auto MDIX USB Interface Future Release The USB interface is a type A USB host connector and is provided for us...

Страница 23: ...hernet ports provide the following 10Base Te 100Base T or 1000Base T via RJ 45 Auto negotiation CSMA CD IEEE 802 3 compatibility Auto MDIX USB Interface Future Release The USB interface is a type A US...

Страница 24: ...code could not be booted WAN NetVanta 3130 only Off The interface is administratively down Green solid The link is up and everything is operational Green flashing The port has activity Red solid An al...

Страница 25: ...There is activity on the link Red solid An alarm condition is occurring on the USB port or there is a failure LINK GIG 1 GIG 3 1700340F1 only Off The port is administratively disabled or does not hav...

Страница 26: ...be installed in a wallmount or tabletop configuration The NetVanta 3140 P N 1700341F1 can be mounted in a rack alone or with two units side by side using the optional dual mounting tray P N 1700508F1...

Страница 27: ...ion 1 Decide on a location for the unit Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are viewable 2 Prepare the mounting surface by attaching a board typically...

Страница 28: ...p left or right Figure 14 illustrates the unit mounted with the front panel facing to the left Keep in mind that the unit needs to be mounted at or above eye level so that the LEDs are viewable 3 Prep...

Страница 29: ...NetVanta 3100 Series Hardware Installation Guide Unit Installation 61700600L2 34C Copyright 2015 ADTRAN Inc 29 Figure 14 NetVanta 3140 Single Wallmount Installation...

Страница 30: ...eeds to be mounted at or above eye level so that the LEDs of both units are viewable 3 Prepare the mounting surface by attaching a board typically plywood 3 4 inch to 1 inch thick to a wall stud using...

Страница 31: ...he equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer Installation of the equipment in a rack should be such that the amount of air flow required...

Страница 32: ...screws shipped with the mounting brackets when attaching them to the chassis 2 To allow proper grounding scrape the paint from the rack around the mounting holes where the NetVanta will be positioned...

Страница 33: ...he screws provided 2 To allow proper grounding scrape the paint from the rack around the mounting holes where the tray will be positioned 3 Position two NetVanta units side by side on the mounting tra...

Страница 34: ...s Powering the NetVanta 3120 Series 3130 Series 3140 Desktop To power the NetVanta 3120 Series NetVanta 3130 Series and the NetVanta 3140 Desktop follow these instructions Figure 18 NetVanta 3100 Seri...

Страница 35: ...of the unit Connect the other end of the power cord into a properly grounded AC power source Your NetVanta unit is now ready to be configured and connected to the network For information on configurat...

Страница 36: ...Unit Installation NetVanta 3100 Series Hardware Installation Guide 36 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Страница 37: ...rail switch ports only 7 8 Unused Table A 2 1000Base T Gigabit Ethernet Port Pinouts NetVanta 3140 Pin Name Description 1 TRD0 Transmit Receive Positive 2 TRD0 Transmit Receive Negative 3 TRD1 Transm...

Страница 38: ...lation Guide 38 Copyright 2015 ADTRAN Inc 61700600L2 34C Table A 4 DBU Connector Pinouts Pin Name Description 1 2 Unused 3 R Network Ring 4 T Network Tip 5 6 Unused Table A 5 ADSL Connector Pinouts Pi...