Chapter 6. Terminal Menu and System Control
61200266L1-1
ATLAS 810
PLUS
User Manual
6-15
» BONDING Config
»» TXINIT Timer (sec)
This option specifies the length of time the originating endpoint attempts to
detect the BONDING negotiation pattern from the answering endpoint be-
fore deciding the BONDING call has failed.
»» TXFA Timer (sec)
This option specifies the length of time both endpoints attempt to detect the
BONDING frame pattern when a call is connected before deciding the
BONDING call has failed. When interoperating with other manufacturers’
BONDING equipment, it may be necessary to change this time so that it
matches TXADD01.
»» TXADD01Timer (sec)
This option specifies the length of time both endpoints wait for the addition-
al calls to be connected at the end of negotiation before deciding the BOND-
ING call has failed. The factory default setting is sufficient for most calls to
connect, although when dialing overseas, it may be necessary to lengthen
this timer to allow for slower call routing.
»» TXDEQ Timer (sec)
This option specifies the length of time both endpoints attempt to equalize
the network delay between the bearer channels before deciding the BOND-
ING call has failed.
»» TANULL Timer (sec)
This option specifies the length of time the answering endpoint attempts to
detect the BONDING negotiation pattern from the originating endpoint be-
fore aborting the clear channel mode. It may be necessary to shorten this
time if the DTE equipment using the BONDING module also has timer con-
straints for completing non-BONDING parameter negotiation.
»» TCID Timer (sec)
This option specifies the length of time both endpoints attempt to negotiate
an agreeable value for bearer channels and channel capacities before decid-
ing the BONDING call has failed.
»» Call Stagger
This option specifies the amount of delay placed between calls. Options in-
clude No Stagger, 100 ms, 200 ms, 500 ms, 1 sec, and 2 sec.
» Alarm Relay Reset
Clears the Alarm Relay located on the rear panel of the ATLAS 810
PLUS
.
» Alarm Relay
Threshold
Logs Event Thresholds necessary to set Alarm Relay. These thresholds in-
clude Critical, Major, Minor, Warning, and Normal.
Содержание ATLAS 810 Plus
Страница 1: ...7 6 3 86 8VHU 0DQXDO 3DUW 1XPEHU 3DUW 1XPEHU 61200266L1 1A July 1999...
Страница 10: ...x...
Страница 20: ...List of Tables xx ATLAS 810PLUS User Manual 61200266L1 1...
Страница 28: ...Chapter 1 Introduction 1 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 38: ...Chapter 2 Installation 2 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 42: ...Chapter 3 Operation 3 4 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 52: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 76: ...Chapter 6 Terminal Menu and System Control 6 24 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 84: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 124: ...Chapter 9 Dial Plan Terminal Menu 9 30 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 130: ...Chapter 10 Updating Firmware 10 6 ATLAS 810PLUS User Manual 61200266L1 1 Figure 10 2 Update Firmware Menu Interface...
Страница 160: ...Appendix A System Event Logging A 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 174: ...Appendix E Glossary E 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 186: ...Index Index 12 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 188: ......