Chapter 6. Terminal Menu and System Control
61200266L1-1
ATLAS 810
PLUS
User Manual
6-11
Current CSS Thrsh
The DS1 performance monitor Threshold Value for the Current 15 minute
Controlled Slip Seconds (SES) parameter. The default value is 1 for an ap-
proximate BER level of 10E-5.
Current PCV Thrsh
(D4)
The DS1 performance monitor Threshold Value for the Current 15 minute
Path Code Violation (PCV) parameter, when the Line Type is Super Frame
(AT&T D4 format) DS1. The default value is 72 Framing errors for an ap-
proximate BER level of 10E-5.
Current PCV Thrsh
(ESF)
The DS1 performance monitor Threshold Value for the Current 15 minute
Path Code Violations (PCV) parameter, when the Line Type is Extended Su-
per Frame (ESF) DS1. The default value is 13,296 CRC errors for an approx-
imate BER level of 10E-5.
Current LES Thrsh
The DS1 performance monitor Threshold Value for the Current 15 minute
Line Errored Seconds (LES) parameter. The default value is 65 for an approx-
imate BER level of 10E-5.
Current LCV Thrsh
The DS1 performance monitor Threshold Value for the Current 15 minute
Line Code Violations (LCV) parameter. The default value is 13,340 for an ap-
proximate BER level of 10E-5.
»» DS1 Total Current
Perf Threshold
Defines performance threshold values for DS1 Line and Path statistics. If a
statistic value exceeds its threshold value, then the corresponding Alert Trap
will be sent if the alert event is armed and Alert Taps are enabled. These
threshold apply to all DS1 interfaces in the system.
Total ES Thrsh
The DS1 performance monitor Threshold Value for the Total Errored Sec-
onds (ES) parameter. The default value is 648 for an approximate BER level
of 10E-5.
Total SES Thrsh
The DS1 performance monitor Threshold Value for the Total Severely Er-
rored Seconds (SES) parameter. The default value is 100 for an approximate
BER level of 10E-5.
Total SEFS Thrsh
The DS1 performance monitor Threshold Value for the Total Severely Er-
rored Framing Seconds (SEFS) parameter. The default value is 17 for an ap-
proximate BER level of 10E-5.
Total UAS Thrsh
The DS1 performance monitor Threshold Value for the Total Unavailable
Seconds (UAS) parameter. The default value is 10 for an approximate BER
level of 10E-5.
Total CSS Thrsh
The DS1 performance monitor Threshold Value for the Total Controlled Slip
Seconds (SES) parameter. The default value is 4 for an approximate BER lev-
el of 10E-5.
Total PCV Thrsh
(D4)
The DS1 performance monitor Threshold Value for the Total Path Code Vio-
lations (PCV) parameter, when the Line Type is Super Frame (AT&T D4 for-
mat) DS1. The default value is 691 Framing Errors for an approximate BER
level of 10E-5.
Total PCV Thrsh
(ESF)
The DS1 performance monitor Threshold Value for the Total Path Code Vio-
lations (PCV) parameter, when the Line Type is Extended Super Frame
Содержание ATLAS 810 Plus
Страница 1: ...7 6 3 86 8VHU 0DQXDO 3DUW 1XPEHU 3DUW 1XPEHU 61200266L1 1A July 1999...
Страница 10: ...x...
Страница 20: ...List of Tables xx ATLAS 810PLUS User Manual 61200266L1 1...
Страница 28: ...Chapter 1 Introduction 1 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 38: ...Chapter 2 Installation 2 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 42: ...Chapter 3 Operation 3 4 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 52: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 76: ...Chapter 6 Terminal Menu and System Control 6 24 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 84: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 124: ...Chapter 9 Dial Plan Terminal Menu 9 30 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 130: ...Chapter 10 Updating Firmware 10 6 ATLAS 810PLUS User Manual 61200266L1 1 Figure 10 2 Update Firmware Menu Interface...
Страница 160: ...Appendix A System Event Logging A 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 174: ...Appendix E Glossary E 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 186: ...Index Index 12 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 188: ......