Chapter 9. Dial Plan Terminal Menu
61200266L1-1
ATLAS 810
PLUS
User Manual
9-11
»» Outgoing Number
Conversion
Write Security: 3 Read Security: 5
Defines the rules for converting as-dialed numbers into ISDN number type
and plan.
As dialed
Send digits provided as unknown number type.
ISDN - National pref
Convert to ISDN type, using the 10-digit national form if possible.
ISDN - Subscriber
pref
Convert to ISDN type, using the 7-digit subscriber form if possible.
ISDN - National
DMS Reserved pref
Send digits provided as National Number Type, DMS Reserved Numbering
Plan.
»» Strip MSD
Write Security: 3 Read Security: 5
Strips a selected quantity of the Most Significant Digits (MSD) of a dialed
number prior to being forwarded out of the port. For example, a Network
port set to accept all calls beginning with 9 (9$) and
Strip MSD
set to 1,
sends all digits toward the Network except the leading 9.
»» Netwrk Spec. Fac.-
Voice
Write Security: 3 Read Security: 5
(Network Specific Facility - Voice) Defines specific facility IEs to send to the
Network. Use this option if the customer has subscribed to a network spe-
cific facility service such as AT&T Megacom service. The facility request
sent can be different for voice calls versus data calls. A setting of
1RUPDO
indicates no special facilities have been subscribed.
»» Netwrk Spec.-Fac.
Data
Write Security: 3 Read Security: 5
(Network Specific Facility - Data) Defines specific facility IEs to send to the
Network. Use this option if the customer has subscribed to a network spe-
cific facility service such as AT&T Megacom service. The facility request
sent can be different for voice calls versus data calls. A setting of
1RUPDO
indicates no special facilities have been subscribed.
»» Called Digits
Transferred
Write security: 2; Read security: 5
Defines the number of digits to expect (choose from
1RQHñý7KUHHñý)RXUñ
and
$OO
). The default is All and would almost always be correct. If less than All
digits are sent, then the prefix is defined below. Use this option for PRI
switches that only send a portion of the called number (like DID).
When a 4ESS is configured, many installations will require the
national form where possible; this may also be the preferred form
in 10-digit calling areas.
Strip MSD
does not affect the
Call Accept
criteria. All of the
digits (including the MSDs that are subsequently stripped) are used
as Accept criteria.
Содержание ATLAS 810 Plus
Страница 1: ...7 6 3 86 8VHU 0DQXDO 3DUW 1XPEHU 3DUW 1XPEHU 61200266L1 1A July 1999...
Страница 10: ...x...
Страница 20: ...List of Tables xx ATLAS 810PLUS User Manual 61200266L1 1...
Страница 28: ...Chapter 1 Introduction 1 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 38: ...Chapter 2 Installation 2 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 42: ...Chapter 3 Operation 3 4 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 52: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 76: ...Chapter 6 Terminal Menu and System Control 6 24 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 84: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 124: ...Chapter 9 Dial Plan Terminal Menu 9 30 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 130: ...Chapter 10 Updating Firmware 10 6 ATLAS 810PLUS User Manual 61200266L1 1 Figure 10 2 Update Firmware Menu Interface...
Страница 160: ...Appendix A System Event Logging A 10 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 174: ...Appendix E Glossary E 8 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 186: ...Index Index 12 ATLAS 810PLUS User Manual 61200266L1 1...
Страница 188: ......