Section 6 Troubleshooting Guide
TRACER 4108/4208 System Manual
56
© 2003 ADTRAN, Inc.
612804208L1-1B
1.
OVERVIEW
This troubleshooting guide provides recommended actions for various conditions of the TRACER 4108/4208
system. The status LEDs (located on the front panel of the unit) provide information to help determine the
necessary troubleshooting action. Recommended actions for resolving possible status LED indicators are
contained in this guide.
2.
LED INDICATORS
PWR LED
If the
PWR
LED is not
ON
and solid green, it is an indicator that the TRACER 4108/4208 is not receiving
adequate DC power.
Recommended Actions:
1. Verify that the power source is delivering between 21 and 60 VDC.
2. Check the polarity of the power connection (referenced to ground) of both the TRACER 4108/4208 unit
and the power source. See
DC Power Connection (Plug-In Terminal Block)
on page 31 for details on
power supply connections.
3. Check the internal fuse. The fuse is accessed from the rear panel of the unit. If this fuse is open,
replace with a 2 A, 250 V (2-inch) slow-blo fuse.
TST LED
The
TST
LED will remain
ON
(solid amber) during power-up to indicate a self-test is in progress. If the
TST
LED is blinking or remains
ON
after 10 seconds, this indicates that the TRACER 4108/4208 unit has failed
the self-test. This is an internal failure, and ADTRAN technical support should be contacted.
RF DOWN LED
If the
RF DOWN
LED is
ON
(solid red), it is an indicator that there is a problem with the RF link to the
remote TRACER 4108/4208.
Recommended Actions:
1. Check the RF coaxial cable connection.
2. Measure the RSSI voltage and consult the RSSI Calibration sheet included with the unit. If the voltage
level corresponds to a received signal power level that agrees with the calculated receive signal level, go
to Step 8.
3. Verify that one end of the link is configured as Plan A and the other end as Plan B, and that both ends
have the same bandplan number (ex. A1 and B1). See
>TRACER System Options > RF Bandplan
on
page 48 for further details.
4. Verify that both ends of the link are configured for the same number of active T1 ports. See
>TRACER
System Options >Active T1 Ports
on page 49 for more details.
5. Verify that the antenna polarization is the same at both ends of the RF signal transmit and receive path.
6. Verify the RF signal path is clear.
7. Check the integrity of the lightning arrestors.
8. Check for possible interference at both ends of the link. If necessary, change polarization and/or
bandplans at both ends.
Содержание 12804108L1A
Страница 10: ...Table of Contents TRACER 4108 4208 System Manual 10 2003 ADTRAN Inc 612804208L1 1B...
Страница 14: ...Section 2 Microwave Path Engineering Basics TRACER 4108 4208 System Manual 14 2003 ADTRAN Inc 612804208L1 1B...
Страница 24: ...Section 2 Microwave Path Engineering Basics TRACER 4108 4208 System Manual 24 2003 ADTRAN Inc 612804208L1 1B...
Страница 40: ...Section 4 Network Turnup Procedure TRACER 4108 4208 System Manual 40 2003 ADTRAN Inc 612804208L1 1B...