Section 5 User Interface Guide
TRACER 4108/4208 System Manual
54
© 2003 ADTRAN, Inc.
612804208L1-1B
>T1
X
P
ERFORMANCE
H
ISTORY
Figure 13 shows the T1x Performance History menu page, which displays detailed error statistics for the
T1 link (from both the local and remote TRACER 4108/4208 units) in 15-minute increments.
Figure 13. T1x Link Performance History
T1 performance data is presented as Errored Seconds (ES) and Severely Errored Seconds (SES) on the T1
link. The following events qualify as an ES–AIS, LOS or LOF Alarm Second, a single bipolar violation
(BPV), excessive zero event, or a single parity bit. An SES is caused by an AIS, LOS or LOF Alarm
Second, excessive BPVs, or framed parity bit errors causing a line bit error rate (BER) of 10
-6
.
The error count for the most recent 24 hours are recorded and displayed on the right side of the page. The
left side of the page displays the 24 hour totals for the most recent 7 days.
The following menus for the T1x Performance History apply to all eight available T1
interfaces (A through H).
Press <
N
> to view the next 8 hours worth of 15-minute totals and <
P
> to view the
previous 8 hours.
24
Hours
7
Days
Содержание 12804108L1A
Страница 10: ...Table of Contents TRACER 4108 4208 System Manual 10 2003 ADTRAN Inc 612804208L1 1B...
Страница 14: ...Section 2 Microwave Path Engineering Basics TRACER 4108 4208 System Manual 14 2003 ADTRAN Inc 612804208L1 1B...
Страница 24: ...Section 2 Microwave Path Engineering Basics TRACER 4108 4208 System Manual 24 2003 ADTRAN Inc 612804208L1 1B...
Страница 40: ...Section 4 Network Turnup Procedure TRACER 4108 4208 System Manual 40 2003 ADTRAN Inc 612804208L1 1B...