SCU, Multiplexer, CSM, and Access Module Installation
61181001L1-5E
27
To connect the Total Access 3000 Chassis to the Ethernet ring, simply plug the male RJ-45
modular connector into the female RJ-45 port on the Total Access 3000 backplane. When
planning the cable run to the Total Access 3000 Chassis, be sure to allow enough cable for
routing the cable from the backplane connector to the frame, and for neat tie-off in accordance
with CO SOP.
SCU, MULTIPLEXER, CSM, AND ACCESS MODULE INSTALLATION
The manner in which the Total Access 3000 functions is totally dependent on the modules
that are placed into the System. For information on specific module functionality, refer to the
Total Access 3000/3010 System Manual (P/N 61181001L1-1).
Unpacking and Inspecting Modules
Each module is shipped in its own cardboard shipping carton. Open the carton carefully and
avoid puncturing the carton with sharp objects. After removing the unit from the carton,
unwrap the bubble-wrap and pull the unit from the antistatic plastic bag.
After unpacking the unit, inspect it for damage. If the equipment has been damaged, file a
claim with the carrier and then contact ADTRAN Customer Service.
Installing Modules
The SCU must be placed in the slot labeled
SCU
. Multiplexer or Cell Switch Modules must be
placed in either the slot labeled
A
or
B
. Access modules must be placed in any of the 28 slots,
labeled
1
through
28
. Gently but firmly push the module into the desired slot of the chassis.
Simultaneous thumb pressure at the top and bottom of the unit will ensure a good seat of the
module’s pins into the backplane connector. Push the ejector tab up and closed against the
front panel of the module. Use the documentation shipped with the individual module to verify
the proper sequence of LED illuminations.
NOTE
Any slots that are not occupied by an access module must be
covered with a blank front panel. The part numbers for these are
listed below:
• Slot A or B
1181952L1
• Slots 1-28
1181953L1
MAINTENANCE
The ADTRAN Total Access 3000 23-inch chassis requires no routine maintenance to operate
properly. Conduct tests and maintenance for the specific plug-ins in accordance with the
recommendations and procedures prescribed by the documentation of each specific plug-in.
ADTRAN does not recommend that repairs be attempted in the field. Repair services may be
obtained by returning the defective unit to ADTRAN. Refer to
for
further information.