4.12 Order of installation (OPC8013-8022) 

 

 

 

ACHTUNG

 

The screws have to be tighten with a torque 
of 0.25 NM 

 

 

Information: 

The connection to the power supply network is established via the 
included power cable or lead-through terminal with screw connection. 
No earthing connection needs to be established as earthing takes 
place via the protective earth of the device plug / power supply 
connection. In the event of additional earthing on the earthing screw, 
use wire cross section with at least 2.5 mm².

 

Содержание OPC8008

Страница 1: ...Instruction manual Industrial PCs OPC8000 series Version 2 2 Translation of the original instruction manual Effective as of 02 02 2017 ...

Страница 2: ...e 15 3 3 Warranty repairs 15 3 4 Intended use 16 3 5 Improper use 16 3 6 Treatment and disposal of lithium batteries 17 3 7 Safety instructions 18 4 Installation 19 4 1 Installation option 19 4 2 External device dimensions OPC8008 20 4 3 External device dimensions OPC8008 21 4 4 External device dimensions OPC8013 22 4 5 Installation layout OPC8013 23 4 6 External device dimensions OPC8015 24 4 7 I...

Страница 3: ...USB connections 44 7 4 Network connection RJ45 45 7 5 Serial interface COM RS232 46 8 Drives 47 8 1 Hard disk Flash SSD 47 8 2 External drives 47 9 Software 48 9 1 Configuration Center 48 10 Technical details 49 11 Service support 51 11 1 ADS TEC support 51 11 2 Company address 51 12 Component replacement 52 12 1 Opening the service slot OPC8008 52 12 2 Opening the service slot OPC8013 8022 54 12 ...

Страница 4: ...al version of this instruction manual was written in German All non German versions of this instruction manual are translations of the German instruction manual 1 2 Limitation of liability ADS TEC GmbH shall not be liable for personal injury property damage or damage caused to the device as well as consequential damage that is was the result of non compliance with this instruction manual improper ...

Страница 5: ...decisive to device setup and operation Instruction manual this documentation Contains information for installation commissioning and operation of the device along with technical data of the device hardware Website You can download drivers software user manuals leaflets and flyers about the product from our website www ads tec de ...

Страница 6: ...rd Measures to prevent hazard 2 2 Graduation of risk level The signal word classifies the hazard Instructions for preventing the hazard are identified by an arrow 2 3 Explanation of used symbols DANGER Indicates an imminent danger If not avoided death or severe injury will result WARNING Indicates a possible danger If not avoided death or severe injury could result CAUTION Indicates a possible dan...

Страница 7: ...must not be disposed of with household waste but must rather be taken to a collection point for waste electrical equipment Such a collection point is generally operated by public waste management authorities i e by municipalities Symbol for the protective earth connection 2 5 Data figures and modifications All data text and figures were prepared to the best of our knowledge They do not represent a...

Страница 8: ... user simple usage rights are granted within the scope of the intent of the contract Any modified use or exploitation of the provided content particularly duplication modification or publishing in whatever form is permitted only with the prior consent of ADS TEC In the case of copyright infringement ADS TEC reserves the right to exercise all rights ...

Страница 9: ...h Flash SSD for storage 20 to 55 C Temperature for OPC8013 8015 devices in operation 5 to 45 C in operation 20 to 60 C only with Flash SSD automotive hard disk or 2 5 Industrial SSD for storage 30 to 65 C for storage 30 to 75 C only with Flash SSD automotive hard disk or 2 5 Industrial SSD Temperature for OPC8022 device in operation 5 to 45 C for storage 20 to 60 C Humidity in operation 10 to 85 w...

Страница 10: ...ww ads tec de support support anfrage html and is available for download at http www ads tec de support download eg konformitaetserklaerung html Recommendation for use For full compliance with the EMC legislation all components and cables used for device connection must also be compliant with these requirements It is therefore necessary to employ BUS and LAN cables with shielded connectors and the...

Страница 11: ...sion in a new form Optimised in every detail with multi touch operation and rear service access for simple and safe replacement of all components In wide screen format in four different sizes reduced to the essential without compromise powerful and with long term availability Front side Fig 1 No Description 1 Display with touch screen 2 Front keys with lighting 3 Status indicator ...

Страница 12: ...OPC8000 series 12 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Rear side Fig 2 No Description 4 Service slot 5 Tensioners for installation purposes ...

Страница 13: ...OPC8000 series 13 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Rear side Fig 3 No Description 4 Tensioners for installation purposes 5 Service slot ...

Страница 14: ...All users must read this manual and have access to it at all times Installation commissioning and operation may only be performed by qualified and trained personnel The safety notices and the manual itself must be observed by all persons who work with this device At the installation site the valid guidelines and regulations for accident prevention must be observed The manual contains the most impo...

Страница 15: ...uctuations The device should only be switched on after it has acclimated to the ambient temperature To avoid overheating in operation The device must not be exposed to direct radiation by sunlight or any other heat source 3 2 Damage due to improper use Should the control system have evident signs of damages caused e g by improper operation or storage conditions or due to improper use or handling t...

Страница 16: ...tions for which further approvals beyond the manufacturer s declaration are necessary e g applications with explosion hazard medical technology shipping industry The device must not be put into operation in the case of transport damage or nonconformity with the specifications and if necessary must be taken out of operation in the case of changing conditions In the case of improper use ADS TEC shal...

Страница 17: ...exposed to higher temperatures the faster it ages Avoid thermal loads WARNING Hazard due to explosion Danger of explosion if using incorrect battery types Use the battery type recommended by the manufacturer Lithium batteries may only be replaced by the same type or by a type recommended by the manufacturer The used lithium battery should be disposed of in accordance with local legal regulations T...

Страница 18: ... caused by electrostatically sensitive components All installation and service work performed on the device must be performed only under safe secure and de energised conditions Recommendation for use Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges The provisions of DIN EN 61340 5 1 DIN EN 61340 5 2 apply ...

Страница 19: ...e must not be exposed to direct radiation by sunlight or any other light source If the device is installed in a panel casing or similar it must be ensured that no heat accumulation occurs The maximum permissible ambient temperature must not be exceeded Devices with data drives must only be installed vertically Any deviation must be arranged with ADS TEC GmbH IP 65 on the front is only achieved wit...

Страница 20: ...OPC8000 series 20 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 2 External device dimensions OPC8008 Abb 4 ...

Страница 21: ...OPC8000 series 21 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 3 External device dimensions OPC8008 ...

Страница 22: ...OPC8000 series 22 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 4 External device dimensions OPC8013 Fig 5 ...

Страница 23: ...OPC8000 series 23 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 5 Installation layout OPC8013 ...

Страница 24: ...OPC8000 series 24 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 6 External device dimensions OPC8015 Fig 6 ...

Страница 25: ...OPC8000 series 25 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 7 Installation layout OPC8015 ...

Страница 26: ...OPC8000 series 26 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 4 8 External device dimensions OPC8022 ...

Страница 27: ...OPC8000 series 27 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Fig 7 4 9 Installation layout OPC8022 ...

Страница 28: ...ion ATTENTION The grub screw of the Quick Snap element must not protrude when folding in but must rather be flush with the tensioner Non compliance may result in damage to the device ATTENTION The grub screws must not be screwed in while folded in Non compliance may result in damage to the touch screen of the device ...

Страница 29: ...allation OPC8008 ACHTUNG The screws have to be tighten with a torque of 0 25 NM 1 Before the device can be integrated in the panel the tensioner fixing screws must be loosened until the tensioners open Item 1 item 2 Information Tensioners can be opened by using an Allen key of 3 mm size ...

Страница 30: ... Hertz Str 1 72622 Nürtingen 2 Now position the device inside the installation recess ATTENTION In order to position the device correctly the opened tensioners should be held back by hand while inserting the device in the installation recess ...

Страница 31: ...OPC8000 series 31 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 3 Fasten the tensioner screws with 0 25 NM until once the device is installed in the recess Item 3 ...

Страница 32: ...tion The connection to the power supply network is established via the included power cable or lead through terminal with screw connection No earthing connection needs to be established as earthing takes place via the protective earth of the device plug power supply connection In the event of additional earthing on the earthing screw use wire cross section with at least 2 5 mm ...

Страница 33: ...out recess in the switch board or switching cabinet door according to the installation layout The fixing screws for the tensioners must be screwed in The screws can be unscrewed with a size TX8 screwdriver 2 The device is placed in the created recess The tensioners snap back ...

Страница 34: ... Heinrich Hertz Str 1 72622 Nürtingen 3 The device must be carefully pushed into the cabinet Then the tensioners snap forward again The device is now secured in the installation recess 4 The tensioners must be fastened with 0 25 NM ...

Страница 35: ...connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient temperature in order to avoid condensate accumulation Make sure to meet the permissible voltage for this device After switching off and before switching on you must wait for at least 5 seconds Information The shielding of a data cable must alway...

Страница 36: ...000 series 36 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen 5 1 Available Interfaces OPC8008 Abb 8 Variante 1 Nr Description 1 On Off Switch 2 Power Supply 24 V DC 3 1 x COM Port 4 2 x LAN 5 3 x USB 2 0 ...

Страница 37: ... 2 Available interfaces OPC8013 8022 Abb 9 Variante 1 Nr Description 1 On Off Switch 2 Power Supply 24 V DC 3 1 x COM Port 4 5 x USB 2 0 5 3 x LAN Abb 10 Variante 2 Nr Description 1 On Off Switch 2 Power Supply 24 V DC 3 1 x COM Port 4 2 x USB 3 0 5 2 x USB 2 0 5 3 x LAN ...

Страница 38: ...rminals Connect cable for serial parallel data transmission and fasten the plugs to the sockets Plug in all other required cables and secure against slipping out Pos 19 D atentechni k Inbetri ebnahme Betriebsberei tschaft prüfen Betriebsbereitschaft prüfen für OPC C PC PLC OTC ITC VMT Serie Monitore IPC 5100 5500 2400 1100 0 mod_1158905578361_6 doc 381 5 5 Check for operational readiness Check the...

Страница 39: ... using the touch screen Level 2 Decrease display brightness Level 1 Change task Alt ESC in Windows Level 2 Increase display brightness Level 1 F2 on keyboard Level 2 Level 1 Right mouse key function Level 2 SHIFT key for activating the second keyboard level The key has to be pressed shortly and is activated permanently it can be recognized via the blue highlighted keys By pressing the Fn key again...

Страница 40: ...nt side With these two keys simultaneously the devices can be powered ON Please note This functionality is only available with the following types of processors Intel Celeron 2002E 1 50 GHz Intel Core i5 4400E 2 70 GHz Check in your BIOS or in the System control of the operating system to see which type of processor your mainboard uses ...

Страница 41: ...er having activated the front keys you can enter the boot menu immediately after switching the computer on by pressing several times the key with the two rectangles Via the boot menu you can also enter the BIOS setup choose Enter setup Then the front keys have the following functions This key reacts like the Enter key on a real keyboard While booting opens the Boot menu In the BIOS setup leave a m...

Страница 42: ... Activate and deactivate the soft keyboard for letter character input using the touch screen Switches numeric keys on and off only if numeric keys are visible Switching between different representations Alphanumeric keys Numeric keys Function key bar Soft keyboard representation zoom in Soft keyboard representation zoom out Information If functions are to be called for which two keys must be press...

Страница 43: ...The driver software necessary for use is already integrated in the respective operating system Pos 23 D atentechni k Bedienung Status Anzeig en SYS LED SYS LED für VMT60xx Serie 2 mod_1260525540269_6 doc 6876 Note The corresponding driver can be downloaded http www ads tec de industrial it download treiber html in the device series 6 4 Status displays SYS LED Depending on the type of flashing diff...

Страница 44: ...Max switch on current 7A 10ms T 60xx 1 mod_1246631044840_6 doc 5885 Pos 29 D atentechni k Schnittstell en USB Anschluss U SB Anschl uss für VMT 60xx 2 mod_1260457598122_6 doc 6860 7 3 USB connections The USB interfaces are used for connecting peripherals with USB connection These interfaces comply with the USB 2 0 e g USB 3 0 standard requirements USB 2 0 Pin Number Signal Name 1 VDC 2 D 3 D 4 GND...

Страница 45: ...pology must be observed If the drivers required for function are not installed they can be installed from the website www ads tec de 10 100Mbit Pin Number Signal Name 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC 1000 BaseT Pin Number Signal Name 1 D1 2 D1 3 D2 4 D3 5 D3 6 D2 7 D4 8 D4 Pos 32 D atentechni k Schnittstell en Funknetzwer kkar te Funknetzwer kkarte für VMT 6000 Serie 2 mod_1260517076470_6 d...

Страница 46: ... COM RS232 The serial interface is used for digital data transmission The RS232 interface can be connected by using a commercially available 9 pin SUB D cable PIN number Signal name 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Information This interface is not electrically isolated ...

Страница 47: ...ne Laufwerke Exter ne Laufwer ke für OPC 5112 5115 5117 IPC 1100 CPC PLC OTC ITC VMT Serie 0 mod_1158926656205_6 doc 563 8 2 External drives External storage media can be connected via USB interfaces Note here the connecting lines in chapter Interfaces ATTENTION Connecting or disconnecting external drives in operation is not admissible since it cannot be excluded that the drive might be in use whi...

Страница 48: ...stallation Installing the operating system The device does not have any integrated CD drive The installation of the operating system can therefore only be carried out by using the USB interface Procedure for installation The boot drive in the system Bios must be switched to USB in order to boot the device from the USB interface Restart the device and insert a Windows CD Install Windows and set up ...

Страница 49: ...GHz Intel Core i7 2655LE 2 20 GHz Intel Celeron 2002E 1 50 GHz Intel Core i5 4400E 2 70 GHz RAM 4 GB DDR3 4 bis 8 GB DDR3 Graphics controller Intel Intel GMA3600 DirectX 9 0 and OpenGL 3 0 Support Intel HD Graphics bei Celeron 847E DirectX 10 1 and OpenGL 3 1 Support Intel HD Graphics 3000 bei i5 2515E i7 2655LE DirectX 10 1 and OpenGL 3 1 Support Intel HD Graphics bei Celeron 2002E DirectX 11 1 a...

Страница 50: ...o 60 C 5 C to 45 C Dimensions W x H x D 258 x 194 x 62 mm 353 x 261 x 63 mm 426 x 303 x 66 mm 567 x 369 x 66 mm Installation depth 50 mm 51 mm 54 mm 54 mm Installation recess 240 x 176 mm 332 x 240 mm 392 x 269 mm 532 x 334 mm Weight Approx 1 8 kg Approx 3 6 kg Approx 4 9 kg Approx 8 6 kg Vibration DIN EN 60068 2 6 Shock resistance DIN EN 60068 2 27 Humidity 10 to 85 non condensing Pos 40 D atente...

Страница 51: ...tions please contact the system supplier in question as ADS TEC will not be able to answer such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by the partner company 11 1 ADS TEC support The ADS TEC support team is available for inquiries from direct customers between 8 30am and 5 00pm...

Страница 52: ...622 Nürtingen 12 Component replacement ATTENTION Make certain that all cables are disconnected and that no voltage is connected to the device 12 1 Opening the service slot OPC8008 Remove the four screws for the service slot on the rear of the device Fig 13 ...

Страница 53: ...OPC8000 series 53 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Fig 14 By removing the service slot cover it is possible to replace the following components 1 Lithium battery 2 mSATA connection ...

Страница 54: ... Opening the service slot OPC8013 8022 Remove the four screws for the service slot on the rear of the device The screws can be removed with a size Tx 10 screwdriver The rear cover can be tilted forward and removed using the groove on the top side of the service slot Fig 15 ...

Страница 55: ... series 55 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Fig 16 By removing the service slot cover it is possible to replace the following components 1 HDD 2 Fan 3 RAM 4 Lithium battery 5 mSATA connection ...

Страница 56: ...rnal tabs with a flat tool screwdriver Installing replacing the battery The lithium battery can now be removed It may only be replaced with a battery of the same type The type of battery to be used is Lithium battery 1 2AA 3V e g ADS TEC part number DZ SONS 04100 0 Ensure the correct polarity when inserting the battery WARNING There is a risk of explosion if the battery is replaced with the wrong ...

Страница 57: ...2 Nürtingen 12 4 Replacing the HDD hard disk OPC8013 8022 Removal The extraction aid provided on the HDD should be used for removing the HDD Carefully pull out the HDD Installation The HDD must be carefully inserted into the slot and should noticeably engage ...

Страница 58: ...13 8022 ATTENTION Before the device fan can be replaced the fan cable must be unplugged Removal Use a size Tx 10 screwdriver to remove the fan screws The fan can then be lifted out and replaced with a new one Installation Screw the previously removed screws back in and plug the fan cable in again ...

Страница 59: ...orking memory RAM OPC8013 8022 Removal The RAM memory is released by carefully pulling apart the retaining clips 1 2 It can now be replaced with new RAM memory Installation Insert the new RAM memory in the designated slot and push the RAM memory to the back until the retaining clips engage ...

Страница 60: ...7 Replacing the mSATA modules OPC8000 series Information For the devices OPC8013 8022 the HDD hard disk must be removed before the SSD Flash Modules can be installed or replaced Remove the HDD OPC8013 8022 Remove the screw s of the spacer bolt by using a Tx10 screw driver ...

Страница 61: ...OPC8000 series 61 ADS TEC GmbH Heinrich Hertz Str 1 72622 Nürtingen Mounting OPC8000 Serie 1 Mainboard 2 plastic disc 3 plastic distance holder 4 mSATA Card 5 plastic disc ...

Отзывы: