- 27 -
WEIMOD MODE
Receiving instrument works as if the load cell is directly connected to the instrument. It’s therefore
possible to perform calibrations and zero-settings on the receiving instrument. The used protocol is
Modbus (the transmitting instrument works as "slave" and the receiving as "master").
Prior to set the
mode on receiving instrument, it must be set the filter value to
be used on transmitting instrument.
Set
protocol on transmitting instrument (see section
SERIAL COMMUNICATION
SETTING
in instrument manual); the instrument display is automatically locked at power on and
shows the instrument model. To unlock it, if necessary, cut off the connection to the receiving
instrument and follow the procedure in
KEYPAD OR DISPLAY LOCKING
section (see transmitting
instrument manual).
WEIRIP MODE
The instrument receives via serial port the gross weight on the scale and works as if the load cell is
directly connected to the instrument.
However it’s not possible to perform calibrations and zero-settings on the receiving instrument.
These operations must be done on the instrument connected to the load cell.
Set
protocol on transmitting instrument and set
protocol on receiving instrument (see
section
SERIAL COMMUNICATION SETTING
in instrument manual).
On receiving instrument it’s possible to set
and
parameters.
ADN
Pesage