background image

Copyright © 2004, 2020 ADLINK Technology Inc. All Rights Reserved.

 

Revision History. 

1.00 

09-07-2004  Initial release 

1.1 

08-02-2020  Remove Star Trigger Out functionality 

 

Disclaimer 

The information in this document is subject to change without prior notice in 
order to improve reliability, design, and function and does not represent a 
commitment on the part of the manufacturer. 

In no event will the manufacturer be liable for direct, indirect, special, 
incidental, or consequential damages arising out of the use or inability to use 
the product or documentation, even if advised of the possibility of such 
damages. 

This document contains proprietary information protected by copyright. All 
rights are reserved. No part of this manual may be reproduced by any 
mechanical, electronic, or other means in any form without prior written 
permission of the manufacturer. 

 

Trademarks 

NuDAQ™,  NuIPC™,  NuDAM™,  NuPRO™

 

are  registered  trademarks  of 

ADLINK Technology Inc. Other product names mentioned herein are used 
for identification purposes only and may be trademarks and/or registered 
trademarks of their respective companies. 

 

Содержание PXI-7931

Страница 1: ...PXI 7931 4x8 2 Wire Matrix Module User s Manual Manual Rev Rev 1 1 Date February 8 2020 Part Number 50 17009 1010...

Страница 2: ...idental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary informati...

Страница 3: ...mers are encouraged to dispose of them in accordance with the product disposal and or recovery programs prescribed by their nation or company Battery Labels for products with battery California Propos...

Страница 4: ...elp or service please contact us at Ask an Expert http askanexpert adlinktech com ADLINK Technology Inc Web Site http www adlinktech com Sales Service Service adlinktech com Telephone 886 2 8226 5877...

Страница 5: ...anical Drawing 6 2 4 Installing the switch module into a PXI Platform 6 Chapter 3 Signal Connection 9 3 1 PXI 7931 Topology 9 3 2 PXI 7931 Pin assignment Description 10 3 3 TB 6231 Terminal Board 11 C...

Страница 6: ...cifications and applications Chapter 2 Installation Describes how to install a switch module into a PXI chassis For software library and utilities installation please refer to the Software Users Guide...

Страница 7: ...upon the trigger from external measurement devices such as a DMM The scan list can also advance when the scan delay timer expires PXI trigger functions are supported and software programmable Multipl...

Страница 8: ...ax switching voltage 220VDC 125VAC Max switching power 60VA 60W Failure rate 10 A 10mVDC Contact resistance 100m max Relay set reset time Operate time 4ms max Release time 4ms max Bounce time 1ms max...

Страница 9: ...62 pin D submale Operating temperature 0 to 55 C Storage temperature 20 to 70 C Humidity 5 to 95 non condensing Power requirements when all relays are activated simultaneously 5V 3 3V 1A 400mA Dimensi...

Страница 10: ...4 Introduction This page intentionally left blank...

Страница 11: ...ler from whom the product was purchased Keep the shipping materials and carton for future storage or shipping 2 2 Unpacking ADLINK switch module contains sensitive electronic components that can be ea...

Страница 12: ...link the chassis backplane With its modular rugged and high shock resistant mechanical features the switch module functions exceptionally well in any harsh environment application 2 4 Installing the...

Страница 13: ...Installation 7 Figure 2 Installing the switch module into a PXI platform...

Страница 14: ...This page intentionally left blank 8 Installation...

Страница 15: ...ect or disconnect any number of rows to any number of columns in the same bank This configuration can let user simultaneous connects one or more input signals to one or more devices All signal paths o...

Страница 16: ...able 1 Pin Assignment Signal Name Type Description C0 to C15 C0 to C15 Input Output Columns signals are connected to the switch module R0 to R7 R0 to R7 Input Output Rows signals are connected to the...

Страница 17: ...matrix configurations The TB 6231 s default configuration is a 4 group 2x4 matrix in 2 wire If other matrix configurations are preferred users can refer the table below to short the relative pads For...

Страница 18: ...nal Connection Figure 4 2x4 Matrix I In this configuration the TB 6231 would not have any shorted pads The grid below shows the names used for software configuration with corresponding traces to the T...

Страница 19: ...Signal Connection 13 Figure 5 2x4 Matrix II...

Страница 20: ...nk1 each has two rows and eight columns The following diagram illustrates the PXI 7931 with the TB 6231 to produce relative paths Figure 6 2x8 Matrix I To use a 2x8 matrix short the following TB 6231...

Страница 21: ...tion 15 Figure 7 2x8 Matrix II 2x16 Matrix This configuration has one independent 2x16 matrix with two rows and 16 columns The following diagram illustrates the PXI 7931 with the TB 6231 to produce re...

Страница 22: ...tion Figure 8 2x16 Matrix I To use a 2x16 matrix short the following eight TB 6231 pads The grid below shows the names used for software configuration with corresponding traces to the TB 6231 Figure 9...

Страница 23: ...each with four rows and four columns The following diagram illustrates the PXI 7931 with the TB 6231 to produce relative paths Figure 10 4x4 Matrix I To use a 2x16 matrix short the following 16 TB 62...

Страница 24: ...onnection Figure 11 4x4 Matrix II 4x8 Matrix This configuration has one 4x8 matrix Bank0 with four rows and eight columns The following diagram illustrates the PXI 7931 with the TB 6231 to produce rel...

Страница 25: ...gnal Connection 19 Figure 12 4x8 Matrix I To use a 2x16 matrix short the following 24 TB 6231 pads The grid below shows the names used for software configuration with corresponding traces to the TB 62...

Страница 26: ...20 Signal Connection Figure 13 4x8 Matrix II...

Страница 27: ...dshaking the switch module provides eight channels of programmable digital I O interface to facilitate general purpose control applications To make full use of the flexible trigger and signaling syste...

Страница 28: ...n has been debounced and advanced to the next scanlist entry Users can also specify one time or cyclic scanning of scanlist entries This operating mode supports trigger signals for instrument handshak...

Страница 29: ...truments or external measurement devices that the relay contacts have settled and ready to take a new measurement The waveform polarity and pulse width of Scanner Advanced signal can also be software...

Страница 30: ...e 17 the Scanner Advanced is set to pulsating mode Trigger In Scanner Advanced Relay status P Pattern 3 4 Operation start Figure 17 Handshaking operation Scanner Advanced set in pulsating mode Trigger...

Страница 31: ...e two times to guarantee that measurement devices take measurements after the signal path is fully settled and the relays switch as close as possible to their maximum operating speed As the scan delay...

Страница 32: ...VM Comp to S_ADV Follow the instructions below to ensure the handshake functions properly 1 Configure ADLINK PXI switch module s Trigger In to rising edge triggered Scanner Advanced output in active...

Страница 33: ...se refer to the software programming users guide 4 4 Trigger Bus PXI specification defines eight bused lines across slots in a segment Users can route various trigger signal to synchronize multiple PX...

Страница 34: ...28 Operation Theorem Figure 20 Available signal sources for Trigger Bus 7 0 Trigger Bus 7 0 WDT Overflow SHDNn Software Trigger Star Trigger In Trigger In Signal Scanner Adv Signal AUX 3 2...

Страница 35: ...still read back the actual logic level on the I O line All digital lines are pulled up to 5V with 10k ohm input resistance Note that AUX 2 0 are dual function pins driving these pins while enabling ha...

Страница 36: ...h The blue LED on the front panel of the switch module will switch off when it is ready for operation Tighten the screws on the front panel Note Microsoft Windows 2000 does not natively support hot sw...

Страница 37: ...is enabled It will falsely trigger the Switch Module to enter shutdown mode This function is disabled by default For more information please refer to the software programming users guide 4 8 Watchdog...

Страница 38: ...users must periodically reset the timer by software command If the timer is not being reset within the specified interval the switch module will generate an overflow signal and set the relay pattern...

Страница 39: ...not cover repair costs due to a Damage caused by not following instructions b Damage caused by carelessness on the users part during product transportation c Damage caused by fire earthquakes floods...

Отзывы: