Watchdog and Utilities
111
Extraction Process
In the extraction process, the handle can be treated as a power
button. In Windows 2000, Windows 98, or other operating systems
that support ACPI. Trigger the handle once (open then close
handle) and the operating system will shut down automatically. In
other states open the handle for over four seconds, the board will
turn off.
1. Trigger or open the handle.
2. In the OS that supports ACPI, the OS will either shut
down automatically by triggering the handle, or by
opening the handle for over four seconds on unsaved
data status.
3. If the blue LED is on, this would indicated one of two
things: the OS was shut down properly by triggering the
button with handle still closed; or the operator forced the
OS to shut down with the handle still open.
4. Open the handle and the blue led is still on. Operators
can extract the board.
5. Extract the board and the BD_SEL# pin disconnects.
6. Medium length CompactPCI pins disengage.
7. Long length CompactPCI pins disengage. And early
power goes away.
8. Board leaves the ESD card guide.
Note:
If the board is fully seated and handle is closed, but
the blue LED is still on, it indicates the board installs to
the live system fail. And operators must extract the
board and insert again.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание NuIPC cPCI-6760D Series
Страница 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 87: ...74 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 99: ...86 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...