Cooling System
59
4
Cooling System
The cPCIS-3330 Series subsystems are equipped with 10 front-
access hot swappable fans (five intake on the bottom, five exhaust
on the top) and two rear-access hot swappable fans to provide an
effectively cooled environment. The chassis is equipped with an air
filter that is removable for cleaning and/or replacement. The cPCIS-
3330 Series features an embedded alarm board that monitors fan
status and initiates a visible and audible alarm upon fan failure.
4.1 Fan Alarm
The embedded alarm board monitors temperature & fan status.
Should a fan become disabled, the Alarm LED will light up and an
audible warning will be heard.
To disable the audible warning, press the Alarm Reset Button. The
Alarm LED will continue to flash until the faulty fan is replaced.
4.2 Fan Removal and Replacement
To remove and replace a faulty fan module, follow the procedures
below.
Figure 4-1: Front fan tray cover locations
Содержание cPCIS-3330 Series
Страница 4: ......
Страница 8: ......
Страница 14: ...6 Introduction...
Страница 25: ...Backplanes 17 Mechanical Drawing Figure 3 1 cBP 6108R Backplane Front View...
Страница 26: ...18 Backplanes Figure 3 2 cBP 6108R Backplane Rear View...
Страница 44: ...36 Backplanes Mechanical Drawing Figure 3 3 cBP 6408R Backplane Front View...
Страница 45: ...Backplanes 37 Figure 3 4 cBP 6408R Backplane Rear View...