6
Specifications
2.11. Power Specifications
Power Modes
AT and ATX mode (AT mode startup controlled by SEMA Board Controller)
Standard Voltage Input
ATX: 12V±5% / 5Vsb ±5% or AT = 12V±5%
Wide Voltage Input
ATX: 5-20 V / 5Vsb ±5% or AT = 5-20V
Power Management
ACPI 5.0 compliant, Smart Battery support
Power States
Supports C1-C6, S0, S3, S4, S5 (Wake-on-USB S3/S4, WoL S3/S4/S5)
ECO Mode
Supports deep S5 for 5Vsb power saving
2.12. Power Consumption
Please contact your ADLINK representative for the document “COM Express Module Power Consumption”.
2.13. Operating Temperatures
Standard Operating
Temperature
0°C to +60°C (Wide Voltage Input)
Storage: -20°C to +80°C
Extreme Rugged Operating
Temperature (optional)
-40°C to +85°C (Standard Voltage Input)
Storage: -40°C to +85°C
2.14. Environmental
Humidity
Operating: 5-90% RH, non-condensing
Storage:
5-95% RH (and operating with conformal coating)
Shock and Vibration
IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F, Method 213B, Table 213-I, Condition A and Method 214A, Table 214-I,
Condition D
HALT
Thermal Stress, Vibration Stress, Thermal Shock and Combined Test
2.15. Specification Compliance
z
PICMG COM.0: Rev 2.1 Type 6, Compact size 95 x 95 mm
2.16. Operating Systems
Standard Support
•
Windows 10 (64-bit)
•
Linux (64-bit)
•
VxWorks (64-bit)
Extended Support (BSP)
•
Linux (64-bit)
•
VxWorks (64-bit)
Содержание cExpress-KL
Страница 8: ...2 Introduction This page intentionally left blank...
Страница 42: ...36 Connector Pinouts on Module This page intentionally left blank...
Страница 46: ...40 Smart Embedded Management Agent SEMA This page intentionally left blank...
Страница 90: ...84 BIOS Checkpoints Beep Codes This page intentionally left blank...