background image

 

                                                     

Page 18 

7. Guarantee 

(Limited 

Warranty)

 

 

 
 
 

Adkins Labelling Solutions

 warrants that the press is free from defects 

in material and workmanship for a period of 12 months from the date of 
supply to the customer.  The machine comes with a one year warranty 
on parts and 90 days labour. 
 

This warranty covers 

all parts to repair the defects, except when 

damage results from misuse or abuse, accident, alteration or negligence 
or when a machine has been improperly installed. 
 

If a press covered by warranty

 should need to be returned to the 

factory for examination and repair, if on-site component replacement is 
not possible, Adkins Labelling Solutions will make every effort to 
repair the customers press. The warranty will only be effective when 
Adkins Labelling Solutions authorises the original purchaser to return 
the machine to the factory and only when the product upon examination 
has proven to be defective. 
 

Should in our opinion

 any part of this press be defective in materials or 

workmanship, it will be replaced or repaired free of charge, provided 
that the press has been installed and operated in the correct manner and 
not subjected to misuse. If Adkins Labelling Solutions authorise a 
replacement press, the warranty of the replacement press shall expire on 
the anniversary date of the original machines invoice to the customer. 
 

In order for this warranty to be effective

, no return of machine or 

parts may be made without prior factory authorisation. (This will 
exclude any travelling and/or carriage costs which will be charged at 
our discretion). 
 

This is the sole warranty given by the company

; there are no 

warranties, which extend beyond the description on the face hereof. The 
seller disclaims any implied warranty of merchantability and/or any 
implied warranty of fitness for a particular purpose; the buyer agrees 
that the goods are sold “as is”. Adkins Labelling Solutions does not 
warrant that the functions of the press will meet the customer’s 
requirements or expectations. The entire risk as to use, quality and 
performance of the press lies with the customer. (No claim of any kind 
shall be greater than the sale price of the product or part to which the 
claim is made). 
 

In no event will Adkins Labelling Solutions

 be liable for any injury, 

loss or damage, including loss of profits, destruction of goods or any 
special, incidental, consequential or indirect damages arising from the 
use of the press or accompanying materials. This limitation will apply 
even if Adkins Labelling Solutions or its authorised agent had been 
advised of the possibility of such damage.

 

Содержание Beta Swift

Страница 1: ...Operators Manual Beta Swift Heat Press...

Страница 2: ...No part of this publication may be reproduced by any means without the prior written permission of Adkins Labelling Solutions Adkins Beta Swift is a registered trademark of Adkins Labelling Solutions...

Страница 3: ...ully designed and manufactured to ensure that you the user will gain the maximum benefit All Adkins products are specifically designed to ensure ease of use with particular attention to safety require...

Страница 4: ...3 2 Applying Adkins Laundry Labels 8 3 3 Pressing pad assembly 9 3 4 Shutting down the machine 9 3 5 Fault diagnosis 9 4 Maintenance of the Machine 10 4 1 Daily maintenance 10 4 2 Periodic maintenance...

Страница 5: ...n the Swift is fitted with self aligning spring mounted silicone pressure pad to ensure correct pressure and an audible buzzer on the timer mechanism The simple robust machine is powered by a micropro...

Страница 6: ...d and placed in a box and held in place with foam The following articles should have been delivered Beta Swift complete with mains cable and plug Beta Swift Operators Manual Any extra items ordered If...

Страница 7: ...m volume production Specifications Power consumption 0 5kW Power supply 230 240 Volts AC Working temperature 70 235o C Machine height open 61 cm 24 in Machine height closed 28 cm 11 in Machine width 2...

Страница 8: ...will ensure safety Always switch off and isolate the mains supply i e remove plug before undertaking any maintenance work Keep other people away from the machine during use Ensure that there is suffi...

Страница 9: ...ny surfaces that are labelled Caution this plate is HOT MACHINE OPERATION Only suitably trained personnel should operate this machine This machine is designed to be operated by one operator only Do no...

Страница 10: ...move up to the loading position Ensure that no items vulnerable to heat radiation are too close to the machine and that local lighting is adequate 2 3 Electrical requirements The Beta Swift Press sho...

Страница 11: ...ymbol coloured green or green and yellow 2 The wire coloured blue must be connected to the terminal which is marked with the letter N Neutral connector 3 The wire coloured brown must be connected to t...

Страница 12: ...f the above is not the case please refer to Page 13 Control Unit Operation and programme using the settings above 3 2 2 Place the garment on the pressure pad removing all wrinkles 3 2 3 Place the labe...

Страница 13: ...rocker switch to the right of the controller The handle should be in the up position 3 5 Fault Diagnosis This machine has a built in fault diagnosis The display may show the following 1 Heat Fault If...

Страница 14: ...odically clean the Teflon coated heat platen with a non abrasive piece of cloth Stubborn stains may be cleaned when platen is cool with mineral 4 3 Cleaning First unplug the machine Clean the outside...

Страница 15: ...wing pages are the schematic diagrams for the Beta Swift machine 5 1 General Layout Page 12 5 2 Control Unit Operation Page 13 5 3 Exploded Diagram and Parts List Page 14 5 4 Machine Electrical Diagra...

Страница 16: ...ACT TEMP SET TIME 5 1 General Layout of the Beta Swift Press MACHINE OPERATING HANDLE ON OFF SWITCH ON REAR OF CASTING TIME TEMP CONTROL UNIT MODE BUTTON Page 12...

Страница 17: ...temperature When you have set the required temperature the Display will stop flashing and the SET indicator will go out Press the ON OFF button to start the Press heating to the selected temperature...

Страница 18: ...13 INSULATION COVER 15 5 6 125 x 11 7 4 625 x 5 7 cm 2 25 in 1 SWC4 14 LEVER 1 SWC2 15 HEAT PLATE GASKET 1 SWC11 16 CLAMP PLATE 13 3 5 25 x 9 5 3 75 x 1 27 0 5 in 1 SWC13 17 TYPE K THERMO COUPLE 1 FP...

Страница 19: ...n J4 T T U Neutral In J7 Earth On Line Filter Earth On T T U Main Earth Stud On Casting T T U Live Out J5 T T U Neutral Out J6 RT RT GND DI12 Earth Stud On Heat Plate 5 4 Electrical Diagram For elemen...

Страница 20: ...to Press J7 AC N J6 J5 N To Element 1 Connect to Push Button 1 if installing in an Automatic Press 2 Connect to Microswitch if installing in a Manual Press To Mains Earth Stud Ribbon Cable Sockets Buz...

Страница 21: ...ant improvement and or modification to meet changing conditions the right is reserved to change the design and or specifications at any time without prior notification and therefore specifications may...

Страница 22: ...e a replacement press the warranty of the replacement press shall expire on the anniversary date of the original machines invoice to the customer In order for this warranty to be effective no return o...

Страница 23: ...015 Safety of Machinery Emergency Stops BS EN ISO 141211 2007 Safety of Machinery Principles for Risk Assessment BS EN 55011 2016 A1 2017 Class A Group 2 Equipment EMC Emissions BS EN ISO 61000 6 4 20...

Отзывы: