24
BATTERY STATUS AND CHARGING
BATTERY STATUS:
This function is used to check the charge status of the battery. Plug the fixture in and press the
MODE button until “BATT LEV XXX%” is displayed. “XXX” represents the currently remaining battery
life. If “BATT LEV ----” is displayed, it means that the unit is running on AC power. Please do not
fully deplete the battery charge, as this severly shortens the life of the battery.
NOTE: When the battery life is below 30%, the battery percentage number will flash. At 15% power
the fixture will shut off automatically.
NOTE: When using battery power, after 20 seconds of inactivity, the display will revert back to the
battery life display.
BATTERY RECHARGING:
To recharge the battery, plug one end of the supplied AC cord into the AC input on the side of the
unit, and the other end into a matching power supply. It takes approximately 5 hours to reach full
charge (with the power off). The display will STOP flashing when the unit reaches 100% charge.
NOTE: When unplugging the unit from charging and then applying power via battery, there will be a
small charge drop.
For a faster recharging, turn the Load setting to “Off” and turn the battery “On”. See the “Battery
Load” sub-section in the Operating Instructions section of this manual.
PHOTOMETRIC CHART
Distance
0m
1.0m
2.0m
3.0m
4.0m
5.0m
R
D40
917
237
97.8
48.9
32.1
lux
G
D40
951
257
108.5
55.7
37.5
B
D40
815
217
85
53.1
31.7
W
D40
1190
302
113.8
67.6
42.3
A
D40
574
140
50.6
28.9
17.6
UV
D40
179
47.7
38.3
10.9
6.5
RGBWA+UV
D40
4240
966
449
241
154.5