ADJ WiFLY EXR HEX5 IP Скачать руководство пользователя страница 11

11

SETUP

Power Supply: The ADJ WiFly EXR HEX5 IP contains an automatic voltage switch, which will auto-

matically sense the voltage when it is plugged into the power source. With this switch there is no 

need to worry about the correct power voltage, and this unit can be plugged in anywhere.  

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu-

nication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions 

from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only 

have a DATA “OUT” terminal). 

DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 

compliant. When linking several DMX fixtures, try to use the shortest cable path possible in order 

to ensure proper DMX data transmission. The order in which fixtures are connected in a DMX line 

does not influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be 

placed anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. When a fix-

ture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

DMX Cable Requirements: The WiFly EXR HEX5 IP can be controlled via DMX-512 protocol. 

The WiFly EXR HEX5 IP has 5 DMX channel modes (see the DMX Traits section of this manual for 

detailed information). The DMX address is set on the back panel of the WiFly EXR HEX5 IP. 

Cable Requirements: This fixture is designed with special cables for both DMX and power. These 

cables are specifically designed to maintain the integrity of the IP rating. When using this fixture for 

outdoor applications, be sure to ONLY use the ADJ cables that have been manufactured to meet the 

IP rating.

“First” DMX Cables - A special DMX “First” cable (part #WIF901-DMX Cable) may be purchased 

from ADJ to provide a means of data communication with standard DMX fixtures for indoor use. 

These cables will come with the IP rated twist lock connector on one end and either a 3-pin XLR 

male or female connector on the other, depending on model. Be sure to only use these cables for 

intergrading this fixture in a standard DMX chain.

“First” Power Cable – A special power “First” cable is included with every fixture. This cable is used 

to provide power to your fixture. This cable comes with the IP rated twist lock connector on one end 

and a standard 3-prong, grounded connector on the other end. Be sure to only use this cable for 

power distribution. Never attempt to connect this cable to the DMX lines.

You can chain multiple fixtures together through serial linking using the IP rated signal cables pro-

vided through ADJ (part# WIF901-Power Cable). Always be sure to daisy-chain your in and out data 

connections, and never split or “Y” your DMX connections unless you are using an approved DMX 

splitter, such as the ADJ WiFly D6 Branch or the original D6 Branch (both units not IP rated).

Содержание WiFLY EXR HEX5 IP

Страница 1: ...User Manual WIFLY EXR HEX5 IP...

Страница 2: ...injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficie...

Страница 3: ...Battery Precautions 9 Setup 11 Operating Instructions 14 Primary Secondary Configuration Wifly Setup 18 ADJ RFC Operation 19 DMX Traits 20 Color Macros Chart 23 Battery Status and Charging Photometri...

Страница 4: ...tery will keep charge for up to 5 hours full on from a full single charge or 7 hours in energy saving mode This fixture can be used in a stand alone mode or connected in a Primary Secondary configurat...

Страница 5: ...e written down on a piece of paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain an R A number by contacting ou...

Страница 6: ...ich the cords exit from the unit Cleaning The fixture should be cleaned only as recommended by t he manufacturer See the Cleaning section of this manual for details Heat The appliance should be situat...

Страница 7: ...high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note that although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environ...

Страница 8: ...tdoor wet environment with out usage as stated above can lead to component damage and or shortening the lifetime of the fixture Any component damage that has been determined to be the direct result of...

Страница 9: ...such a way as to prevent short circuits that can result in smoke or fire 2 3 Do not disassemble the batteries Never disassemble the batteries as doing so may result in an internal short circuit in th...

Страница 10: ...ork battery performance will deteriorate over time even if stored for a long period of time without being used In addition if various usage condi tions such as charge discharge ambient temperature etc...

Страница 11: ...5 IP can be controlled via DMX 512 protocol The WiFly EXR HEX5 IP has 5 DMX channel modes see the DMX Traits section of this manual for detailed information The DMX address is set on the back panel of...

Страница 12: ...terminator ADJ part number Z DMX T will decrease the risk of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA trans mission in place of 3 pin 5 pin DM...

Страница 13: ...e same DMX address will cause all those fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each...

Страница 14: ...ess the UP or DOWN button so that ON is displayed If ON is displayed already this means that the fixture is already in energy saving mode LED Display On Off To set the LED display light to turn off af...

Страница 15: ...UP and DOWN buttons to find your desired color change mode 3 Press the SET UP button and SPEED XX will be displayed Use the UP and DOWN buttons to adjust the speed of the color change Color Fade Mode...

Страница 16: ...ing battery life If BATT LEV is displayed it means either the battery is dead or the unit is running on AC power Battery Load This is used to turn the PCB On when the battery is being used 1 Press the...

Страница 17: ...return to when power is applied 1 Plug the fixture in and press the MODE button until DMX MODE ADDR XXX is displayed 2 Press the SET UP button until DMX MODE NO XXXX is displayed where XXXX represent...

Страница 18: ...is displayed The unit is now set as the Secondary unit Each secondary unit must be set to the same set ting 4 Connect the first Secondary unit to the Primary The Secondary unit should now start to fo...

Страница 19: ...will switch between static color mode and second ary mode Use the or to scroll through the 63 static colors Once you have found the desired color you can press the FLASH button to activate strobing a...

Страница 20: ...bing slow to fast 160 191 LED On 192 223 Random Strobing slow to fast 224 255 LED On 9 9 Program Selection Mode 000 051 Dimming Mode 052 102 Color Macro Mode 103 153 Color Change Mode 154 204 Color Fa...

Страница 21: ...63 Color Fade 4 064 079 Color Fade 5 080 095 Color Fade 6 096 111 Color Fade 7 112 127 Color Fade 8 128 143 Color Fade 9 144 159 Color Fade 10 160 175 Color Fade 11 176 191 Color Fade 12 192 207 Color...

Страница 22: ...8 will control strobing When Channel 9 is between the values of 103 153 Channel 10 is in Color Change Mode and Channel 11 will control the color change speed When Channel 9 is between the values of 1...

Страница 23: ...115 R B UV 116 119 R W A 120 123 R W UV 124 127 R A UV DMX VALUES COLOR 128 131 G B W 132 135 G B A 136 139 G B UV 140 143 G W A 144 147 G W UV 148 151 G A UV 152 155 B W A 156 159 B W UV 160 163 B A...

Страница 24: ...ay BATTERY RECHARGING To recharge the battery plug one end of the supplied AC cord into the AC input on the side of the unit and the other end into a matching power supply It takes approximately 5 hou...

Страница 25: ...0 0 1 0 0 1 0 0 5 0 5 0 5 0 5 0 0 0 0 0 1 0 1 0 1 0 1 0 Trise Tdow n t t t t m s m s m s m s Dimmer Dimmer Dimmer Dimmer Delay mode DMX delay Trise ms Tdown ms dr 0 0 0 dr 1 800 1300 dr 2 1010 1560 d...

Страница 26: ...ther via the power in out ports The maxi mum number of units that can be linked together in this manner is 10 units DO NOT EXCEED THE NUMBER OF UNITS LISTED ABOVE DO NOT MIX MAKE AND MODEL TYPES WHEN...

Страница 27: ...arranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replac...

Страница 28: ...nd 12 channel mode Warranty 2 Years 730 days Limited Warranty Battery Lifetime depends on charging frequency See Limited Warranty section of this manual for details Auto Sensing Voltage This fixture c...

Страница 29: ...29...

Страница 30: ......

Отзывы: